The U.S. Nuclear Regulatory Commission is in the process of rescinding or revising guidance and policies posted on this webpage in accordance with Executive Order 14151 Ending Radical and Wasteful Government DEI Programs and Preferencing, and Executive Order 14168 Defending Women From Gender Ideology Extremism and Restoring Biological Truth to the Federal Government. In the interim, any previously issued diversity, equity, inclusion, or gender-related guidance on this webpage should be considered rescinded that is inconsistent with these Executive Orders.

Event Notification Report for July 3, 2002

                         
                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           07/02/2002 - 07/03/2002

                              ** EVENT NUMBERS **

38934  39034  39035  39036  39037  
.
!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED  !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38934       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: COLUMBIA GENERATING STATIREGION:  4  |NOTIFICATION DATE: 05/21/2002|
|    UNIT:  [2] [] []                 STATE:  WA |NOTIFICATION TIME: 18:59[EDT]|
|   RXTYPE: [2] GE-5                             |EVENT DATE:        05/03/2002|
+------------------------------------------------+EVENT TIME:        15:40[PDT]|
| NRC NOTIFIED BY:  BOB BROWNLEE                 |LAST UPDATE DATE:  07/02/2002|
|  HQ OPS OFFICER:  JOHN MacKINNON               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |LINDA SMITH          R4      |
|10 CFR SECTION:                                 |                             |
|AUNA 50.72(b)(3)(ii)(B)  UNANALYZED CONDITION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| UNANALYZED CONDITION THAT SIGNIFICANTLY DEGRADED PLANT SAFETY                |
|                                                                              |
| On May 3, 2002, approximately 20 gallons of water was spilled on the floor   |
| of the cable spreading room (CSR).  Some of the water leaked down into rooms |
| below the CSR floor, resulting in an electrical ground on the on the 125-VAC |
| Division 2 battery bus S1-2.  The S1-2 bus remained operable.  It has since  |
| been determined that the pathway for leakage through the floor of the CSR    |
| was cracks in the concrete due to abandoned concrete anchors, and through    |
| shrinkage cracks in the reinforced concrete floor slab.  Shrinkage cracks    |
| are also located in the 525' elevation floor above the Control Room.  These  |
| two floors are considered essential fire rated assemblies and are required   |
| to be "leak tight". These floors have not had a qualified paint/sealant      |
| applied that would render them "leaktight".  Other floors that are fire      |
| rated assemblies are believed to have had the appropriate paint/sealant      |
| applied, but this is being verified.  Should a fire system actuate, or       |
| develop a leak in either the CSR or the room above the Control Room, there   |
| is the potential for leakage through the floors to impact Division 1 or 2    |
| safety-related equipment in the rooms below.  A barrier impairment has been  |
| initiated for the CSR on May 6, 2002 and for the 525' elevation above the    |
| Control Room on May 7, 2002 with compensatory action to include these areas  |
| on an hourly fire/flood tour. With the hourly fire/flood tours in place, the |
| floors of the CSR and the room above the Control Room have been declared     |
| "operable but degraded" per formal assessment of operability, and no longer  |
| represent an unanalyzed condition that significantly degrades plant safety.  |
| The cracks associated with the abandoned anchor bolts have been sealed.      |
| Hourly fire/flood tours remain in effect until both floors have been         |
| properly sealed.                                                             |
|                                                                              |
| The NRC Resident Inspector has been notified of this event.                  |
|                                                                              |
| * * * RETRACTED AT 1600 EDT ON 7/2/02 BY BOB BROWNLEE TO FANGIE JONES * * *  |
|                                                                              |
|                                                                              |
| The licensee is retracting this event notification. It was originally        |
| postulated that due to the prevalence of unsealed concrete cracks, a design  |
| basis flooding scenario would create a significant amount of water leakage   |
| into critical equipment rooms below the floors. After further evaluation it  |
| has been concluded that flooding events in either room would result in       |
| minimal leakage into rooms below, and therefore this condition can not be    |
| characterized as an unanalyzed condition that significantly degrades plant   |
| safety. The CSR floor and the room above the Control Room are "operable but  |
| degraded." Hourly fire/flood tours will remain in effect until both floors   |
| have been properly sealed. The cracks responsible for the observed leakage   |
| for this event have been sealed. Columbia Generating Station will submit a   |
| voluntary Licensee Event Report on this issue due to its generic interest to |
| both the NRC staff and the nuclear industry.                                 |
|                                                                              |
| The licensee notified the NRC Resident Inspector.  The R4DO (Dale Powers)    |
| has been notified.                                                           |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   39034       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: DUANE ARNOLD             REGION:  3  |NOTIFICATION DATE: 07/02/2002|
|    UNIT:  [1] [] []                 STATE:  IA |NOTIFICATION TIME: 10:47[EDT]|
|   RXTYPE: [1] GE-4                             |EVENT DATE:        05/19/2002|
+------------------------------------------------+EVENT TIME:        11:00[CDT]|
| NRC NOTIFIED BY:  CLARE BLEAU                  |LAST UPDATE DATE:  07/02/2002|
|  HQ OPS OFFICER:  JOHN MacKINNON               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |BRUCE JORGENSEN      R3      |
|10 CFR SECTION:                                 |                             |
|AINV 50.73(a)(1)         INVALID SPECIF SYSTEM A|                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       21       Power Operation  |0        Cold Shutdown    |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| RADIATION MONITOR DECLARED INOPERABLE                                        |
|                                                                              |
| While operating in Mode 1, in the process of a controlled shutdown to        |
| perform an elective repair of a condenser tube leak, Division "A" Refuel     |
| Pool Radiation Monitor lost power resulting in a Group 3A Primary            |
| Containment Isolation System (PCIS) actuation.  The Group 3A isolation       |
| function as designed.  Radiation levels in the area of the monitor were      |
| normal and the actuation was considered invalid.                             |
|                                                                              |
| The Radiation Monitor was declared inoperable for maintenance.  The monitor  |
| was declared operable at 1049 CST on 05/20/02 at which time the Group III    |
| isolation was also reset.                                                    |
|                                                                              |
| The NRC Resident Inspector was notified of this event by the licensee.       |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|Other Nuclear Material                           |Event Number:   39035       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  US ARMY                              |NOTIFICATION DATE: 07/02/2002|
|LICENSEE:  US ARMY                              |NOTIFICATION TIME: 10:42[EDT]|
|    CITY:  ABERDEEN                 REGION:  1  |EVENT DATE:        07/01/2002|
|  COUNTY:                            STATE:  MD |EVENT TIME:        19:30[EDT]|
|LICENSE#:  1930563-01            AGREEMENT:  Y  |LAST UPDATE DATE:  07/02/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |PETER ESSELGROTH     R1      |
|                                                |FRED BROWN           NMSS    |
+------------------------------------------------+DALE POWERS          R4      |
| NRC NOTIFIED BY:  JOYCE KUYKENDALL             |                             |
|  HQ OPS OFFICER:  RICH LAURA                   |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NONR                     OTHER UNSPEC REQMNT    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| US ARMY LICENSE VIOLATION INVOLVING A CHEMICAL AGENT DETECTOR                |
|                                                                              |
| The US Army reported that License Item 15 was violated when a technician     |
| attempted to disassemble the cell assembly of a chemical agent detector at   |
| Fort Richardson. The cell assembly contains a radiological source of 300     |
| microcuries of AM-241.  The model number is M43A1.  An investigation was     |
| initiated by the US Army to review this event.  At this time there were no   |
| known personnel contaminations or radiological overexposures.                |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|Other Nuclear Material                           |Event Number:   39036       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  ADAMS CONSTRUCTION COMPANY           |NOTIFICATION DATE: 07/02/2002|
|LICENSEE:  ADAMS CONSTRUCTION COMPANY           |NOTIFICATION TIME: 11:00[EDT]|
|    CITY:  SOUTH BOSTON             REGION:  2  |EVENT DATE:        07/01/2002|
|  COUNTY:                            STATE:  VA |EVENT TIME:        15:40[EDT]|
|LICENSE#:  45-1788701            AGREEMENT:  N  |LAST UPDATE DATE:  07/02/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |LEONARD WERT         R2      |
|                                                |DOUG BROADDUS        NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  RON ROBSON                   |                             |
|  HQ OPS OFFICER:  RICH LAURA                   |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NONR                     OTHER UNSPEC REQMNT    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| DAMAGED TROXLER MOISTURE DENSITY GAUGE                                       |
|                                                                              |
| Adams Construction Company reported that an asphalt roller ran over part of  |
| a Troxler moisture density gauge, model number 4640B, serial number 1752.    |
| The source remained intact and was not leaking.  The gauge was transported   |
| to the asphalt plant located in South Boston, VA.  The gauge will be         |
| examined by Troxler for evaluation and repair.  The gauge contained a source |
| of 8 millicuries of CS-137.                                                  |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|Other Nuclear Material                           |Event Number:   39037       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  POWER RESOURCES                      |NOTIFICATION DATE: 07/02/2002|
|LICENSEE:  POWER RESOURCES                      |NOTIFICATION TIME: 13:34[EDT]|
|    CITY:  GLENROCK                 REGION:  4  |EVENT DATE:        07/01/2002|
|  COUNTY:                            STATE:  WY |EVENT TIME:             [MDT]|
|LICENSE#:                        AGREEMENT:  N  |LAST UPDATE DATE:  07/02/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |BILL JOHNSON         R4      |
|                                                |JOHN HICKEY          NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  BILL KEARNEY                 |                             |
|  HQ OPS OFFICER:  FANGIE JONES                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NINF                     INFORMATION ONLY       |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| MONITOR WELL EXCEEDED TWO OF ITS THREE UPPER CONTROL LIMITS                  |
|                                                                              |
| Monitor well FM6 in the F well field exceeded two of its three upper control |
| limits (UCLs).   A confirmation sample was collected on July 1, 2002.        |
|                                                                              |
| Date 7/1/02                                                                  |
| Chloride (UCL 18 mg/l)  40 mg/l                                              |
| Conductivity (UCL 1121 umhos/cm)  793 umhos/cm                               |
| Bicarbonate (UCL 230 mg/l)  233 mg/l                                         |
| Uranium (UCL 0.1 mg/l)  0.1 mg/l                                             |
|                                                                              |
| The licensee notified NRC Project Manager (Rick Weller).                     |
+------------------------------------------------------------------------------+
.