Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for June 24, 2002

                         
                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           06/21/2002 - 06/24/2002

                              ** EVENT NUMBERS **

39002  39008  39009  39010  39011  39012  

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   39002       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  MA RADIATION CONTROL PROGRAM         |NOTIFICATION DATE: 06/18/2002|
|LICENSEE:  JOSLIN DIABETES CENTER               |NOTIFICATION TIME: 15:58[EDT]|
|    CITY:  BOSTON                   REGION:  1  |EVENT DATE:        06/18/2002|
|  COUNTY:                            STATE:  MA |EVENT TIME:             [EDT]|
|LICENSE#:  15-2661               AGREEMENT:  Y  |LAST UPDATE DATE:  06/18/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |JAMES TRAPP          R1      |
|                                                |FRED BROWN           NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  KENATH TRAEGDE               |                             |
|  HQ OPS OFFICER:  FANGIE JONES                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT - LOST RADIOACTIVE MATERIAL SHIPMENT                  |
|                                                                              |
| The Massachusetts Radiation Control Program was contacted by the Joslin      |
| Diabetes Center about a missing shipment of  500 microcuries of P32.  The    |
| shipment was shipped from Perkin-Elmer on 6/10/02 and received on 6/11/02 at |
| the center.  The package was discovered missing on 6/14/02 and notification  |
| to the state was on 6/18/02.  The center has been searched and further       |
| searches are ongoing.                                                        |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   39008       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SALEM                    REGION:  1  |NOTIFICATION DATE: 06/21/2002|
|    UNIT:  [1] [2] []                STATE:  NJ |NOTIFICATION TIME: 13:30[EDT]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        06/21/2002|
+------------------------------------------------+EVENT TIME:        13:12[EDT]|
| NRC NOTIFIED BY:  JOHN KONOVALCHICK            |LAST UPDATE DATE:  06/21/2002|
|  HQ OPS OFFICER:  RICH LAURA                   +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |JAMES TRAPP          R1      |
|10 CFR SECTION:                                 |                             |
|NINF                     INFORMATION ONLY       |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| VOLUNTARY INFORMATION REPORT ON PLANNED SPDS OUTAGE AT SALEM                
|
|                                                                              |
| "The safety parameter display system (SPDS) is being removed from service to |
| perform planned upgrades to the system. The removal of SPDS from service for |
| Salem Units 1 & 2 also affects the transmission of data from the emergency   |
| response data system (ERDS). Appropriate compensatory measures are in place  |
| while the SPDS system is out of service. SPDS is expected to return to       |
| service by end of August. This is considered a condition warranting          |
| voluntary/courtesy NRC notification"                                         |
|                                                                              |
| The NRC resident inspector has been notified.                                |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Other Nuclear Material                           |Event Number:   39009       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  BUREAU OF INDIAN AFFAIRS             |NOTIFICATION DATE: 06/22/2002|
|LICENSEE:  BUREAU OF INDIAN AFFAIRS             |NOTIFICATION TIME: 13:00[EDT]|
|    CITY:  FAIRFAX                  REGION:  4  |EVENT DATE:        06/21/2002|
|  COUNTY:  OSAGE                     STATE:  OK |EVENT TIME:        09:00[CDT]|
|LICENSE#:  35-15239-02           AGREEMENT:  Y  |LAST UPDATE DATE:  06/22/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |CHARLES MARSCHALL    R4      |
|                                                |JOHN GREEVES         NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  BOB FAVORS                   |                             |
|  HQ OPS OFFICER:  RICH LAURA                   |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|BLO1 20.2201(a)(1)(i)    LOST/STOLEN LNM>1000X  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| STOLEN TROXLER MOISTURE DENSITY GAUGE                                        |
|                                                                              |
| On 9:00 a.m. CDT on 6/22/02, the licensee discovered that their storage shed |
| had been broken into and a Troxler moisture density gauge was stolen.  The   |
| model number is 3440, which contains 8 millicuries of CS-137 and 40          |
| millicuries of Am-Be 241, and serial numbers 18746 and 18745.  The licensee  |
| contacted the local police, Fairfax City Police and Osage County Sheriffs    |
| office.  The storage shed is located 2 miles east of Highway 20 and Highway  |
| 18 in Osage County, Oklahoma.                                                |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   39010       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: HOPE CREEK               REGION:  1  |NOTIFICATION DATE: 06/22/2002|
|    UNIT:  [1] [] []                 STATE:  NJ |NOTIFICATION TIME: 18:27[EDT]|
|   RXTYPE: [1] GE-4                             |EVENT DATE:        06/22/2002|
+------------------------------------------------+EVENT TIME:        14:16[EDT]|
| NRC NOTIFIED BY:  CHRISTOPHER SERATA           |LAST UPDATE DATE:  06/22/2002|
|  HQ OPS OFFICER:  RICH LAURA                   +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |JAMES TRAPP          R1      |
|10 CFR SECTION:                                 |                             |
|ARPS 50.72(b)(2)(iv)(B)  RPS ACTUATION - CRITICA|                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     A/R        Y       100      Power Operation  |0        Hot Shutdown     |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AUTOMATIC SCRAM AT HOPE CREEK DUE TO TURBINE TRIP                            |
|                                                                              |
| "Immediately following the RPS actuation, the success of the SCRAM was       |
| evaluated. Initially, the Rod Worth Minimizer indicated that some control    |
| rods were not fully inserted and control rod 22-31 indicated full out on the |
| Full Core Display. Alternate Rod Insertion (ARI) was initiated as per        |
| established operating procedures. The STA observed all Control Rods except   |
| 22-31 to be fully inserted on the Core Monitoring System before ARI was      |
| initiated, indicating the reactor was shutdown without ARI. The indicated    |
| position of CR 22-31 did not change immediately following the SCRAM, but     |
| changed over time consistent with a known problem with its                   |
| position-indicating probe.                                                   |
|                                                                              |
| "Both Reactor Recirculation Pumps tripped as expected from the turbine trip  |
| above 30% power (End-of-Cycle Recirculation Pump Trip function), and remain  |
| out of service. The Reactor is presently shutdown. Reactor pressure is 700   |
| psig and slowly lowering and reactor level is 32 and stable (normal band     |
| 30-39). Efforts are underway to stabilize and normalize reactor coolant and  |
| metal temperatures to allow the restarting of a Reactor Recirculation        |
| Pump."                                                                       |
|                                                                              |
| The NRC resident inspector was notified by the licensee.                     |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   39011       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: POINT BEACH              REGION:  3  |NOTIFICATION DATE: 06/22/2002|
|    UNIT:  [1] [2] []                STATE:  WI |NOTIFICATION TIME: 17:02[EDT]|
|   RXTYPE: [1] W-2-LP,[2] W-2-LP                |EVENT DATE:        06/21/2002|
+------------------------------------------------+EVENT TIME:        01:00[CDT]|
| NRC NOTIFIED BY:  TRACY ALDRICH                |LAST UPDATE DATE:  06/22/2002|
|  HQ OPS OFFICER:  RICH LAURA                   +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |ROGER LANKSBURY      R3      |
|10 CFR SECTION:                                 |                             |
|NINF                     INFORMATION ONLY       |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| SHIFT SECURITY STAFFING BELOW SECURITY PLAN LEVEL                            |
|                                                                              |
| A security guard failed a random drug test and was immediately removed from  |
| duties.  This placed the site below the minimum security level for           |
| approximately 1 hour. Contact the HOO for more details.                      |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   39012       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: GRAND GULF               REGION:  4  |NOTIFICATION DATE: 06/23/2002|
|    UNIT:  [1] [] []                 STATE:  MS |NOTIFICATION TIME: 02:38[EDT]|
|   RXTYPE: [1] GE-6                             |EVENT DATE:        06/22/2002|
+------------------------------------------------+EVENT TIME:        22:17[CDT]|
| NRC NOTIFIED BY:  ROBERT BRINKMAN              |LAST UPDATE DATE:  06/23/2002|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |CHARLES MARSCHALL    R4      |
|10 CFR SECTION:                                 |                             |
|ARPS 50.72(b)(2)(iv)(B)  RPS ACTUATION - CRITICA|                             |
|AESF 50.72(b)(3)(iv)(A)  VALID SPECIF SYS ACTUAT|                             |
|ACOM 50.72(b)(3)(xiii)   LOSS COMM/ASMT/RESPONSE|                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     A/R        Y       100      Power Operation  |0        Hot Shutdown     |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AUTOMATIC REACTOR SCRAM FOLLOWING SERVICE TRANSFORMER LOCKOUT FOR
REASONS    |
| UNKNOWN                                                                      |
|                                                                              |
| "At  2217 CDT on 6/22/02, GGNS scrammed from 100% CTP.  The scram was the    |
| results of a lockout trip on service transformer 21 (ST21).  Exact cause of  |
| [the] scram has not been determined yet..  [The] Plant is stable and all     |
| parameters are being controlled.  [The] scram is suspected to be due to loss |
| of feedwater (i.e., Rx Low Level) when ST21 tripped.  Div 2 and 3 buses did  |
| deenergize and [their] respective Diesel Generators started and carried      |
| [the] buses."                                                                |
|                                                                              |
| All control rods fully inserted.  RWCU is currently in-service removing      |
| decay heat.  ST21 remains out-of-service.  Electrical loads have been        |
| shifted to ST11 (500KV feed) and the ESF transformer (115KV feed).  The unit |
| is not in any TS A/S for offsite power since 2 of the 3 sources are          |
| available.  The licensee notified the NRC Resident Inspector.                |
|                                                                              |
| * * * UPDATE 0404 EDT ON 6/23/02 FROM ROBERT BRINKMAN TO S. SANDIN * * *     |
|                                                                              |
| "This is an update to Event Notification #39012.  This call in is to report  |
| the 8 hr non-emergency call in under 10CFR50.72(b)(3)(iv)(A).  As reported   |
| earlier, Division 2 and 3 electrical buses deenergized when service          |
| transformer 21 tripped.  Division 2 and 3 Diesel Generators started and      |
| energized these buses.  The actuation of Division 2 and 3 Diesel Generators  |
| is the 'Specified System Actuation' reported by this notification.  Also,    |
| Div. 2 Control Room A/C failed to automatically restart following Div. 2 bus |
| being re-energized.  [The] breaker was closed manually and Control Room A/C  |
| (Div. 2) restarted."                                                         |
|                                                                              |
| The licensee informed the NRC Resident Inspector.  Notified                  |
| R4DO(Marschall).                                                             |
|                                                                              |
| * * * UPDATE 0555 EDT ON 6/23/02 FROM ROBERT BRINKMAN TO S. SANDIN * * *     |
|                                                                              |
| "This notification is to report an 8 hr non-emergency call in under          |
| 10CFR50.72(b)(3)(xiii).  At 0425 CDT, on 6/23/02, the GGNS Control Room was  |
| notified that the EOF had no electrical power.  The site power loop was      |
| deenergized when service transformer 21 tripped, which caused the EOF to     |
| become de-energized (see EN #39012).  The EOF backup generator did not start |
| as required, therefore the EOF (Emergency Operations Facility) did not have  |
| any electrical power.  Normal electrical power was restored to [the] EOF at  |
| 0415 hrs CDT on 6/23/02.  [The] backup EOF was available at all times."      |
|                                                                              |
| The licensee informed the NRC Resident Inspector.  Notified R4DO(Marschall). |
+------------------------------------------------------------------------------+