Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for June 17, 2002

                         
                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           06/14/2002 - 06/17/2002

                              ** EVENT NUMBERS **

38979  38985  38991  38992  38993  38995  

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   38979       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  CALIFORNIA RADIATION CONTROL PRGM    |NOTIFICATION DATE:
06/11/2002|
|LICENSEE:  THE BOEING COMPANY                   |NOTIFICATION TIME: 19:50[EDT]|
|    CITY:  ANAHEIM                  REGION:  4  |EVENT DATE:        06/11/2002|
|  COUNTY:                            STATE:  CA |EVENT TIME:             [PDT]|
|LICENSE#:  0065-30               AGREEMENT:  Y  |LAST UPDATE DATE:  06/11/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |ANTHONY GODY         R4      |
|                                                |THOMAS ESSIG         NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  ROBERT GREGER                |                             |
|  HQ OPS OFFICER:  RICH LAURA                   |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT FROM CA REGARDING POTENTIAL PERSONNEL
OVEREXPOSURE    |
|                                                                              |
| The California state radiation safety officer called in a potential 20.2202  |
| personnel overexposure incident that occurred at The Boeing Company in       |
| Anaheim, California.  The licensee utilizes irradiator facilities large      |
| enough for an individual to enter. The individual's dosimeter was read by    |
| the personnel monitoring vendor (i.e.,  Landauer) as 94 Rem DDE, 94 Rem LDE  |
| and 112 Rem SDE.  The dosimetry was worn during the period of April 1 to     |
| April 30, 2002.  The licensee commenced an investigation to determine the    |
| validity of the high and unexpected reading.  The licensee will conduct an   |
| interview with the individual and also the State indicated a blood test will |
| most likely be performed. The State indicated the badge received a "static"  |
| exposure, and it will probably turn out to be a dosimeter-only exposure.     |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   38985       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  TEXAS DEPARTMENT OF HEALTH           |NOTIFICATION DATE: 06/12/2002|
|LICENSEE:  FURGO SOUTH INC.                     |NOTIFICATION TIME: 17:30[EDT]|
|    CITY:  HOUSTON                  REGION:  4  |EVENT DATE:        06/12/2002|
|  COUNTY:  HARRIS                    STATE:  TX |EVENT TIME:        12:00[CDT]|
|LICENSE#:  L00058                AGREEMENT:  Y  |LAST UPDATE DATE:  06/12/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |ANTHONY GODY         R4      |
|                                                |LARRY CAMPER         NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  HELEN WATKINS (via fax)      |                             |
|  HQ OPS OFFICER:  STEVE SANDIN                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT INVOLVING A STOLEN TROXLER GAUGE                      |
|                                                                              |
| "A technician was transporting a gauge that was chained, locked, and secured |
| on the back of a pickup truck. He stopped at a restaurant for a take out     |
| lunch. Upon returning to the truck, he noticed the gauge was missing. The    |
| chain was cut.                                                               |
| Some other items, including test equipment and a sand cone, were taken.      |
| Gauge: Troxler Model 3430, ser#26992 Sources: 8 mCi Cs-137 ser#750-171 [and] |
| 40 mCi Am-241 ser#47-23560."                                                 |
|                                                                              |
| The local police, Troxler Electronics and the TXDOT were informed.  Texas    |
| Incident No.:  I-7907                                                        |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38991       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SOUTH TEXAS              REGION:  4  |NOTIFICATION DATE: 06/14/2002|
|    UNIT:  [] [2] []                 STATE:  TX |NOTIFICATION TIME: 07:14[EDT]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        06/14/2002|
+------------------------------------------------+EVENT TIME:        04:35[CDT]|
| NRC NOTIFIED BY:  KLAY KLIMPLE                 |LAST UPDATE DATE:  06/14/2002|
|  HQ OPS OFFICER:  LEIGH TROCINE                +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |ANTHONY GODY         R4      |
|10 CFR SECTION:                                 |                             |
|ARPS 50.72(b)(2)(iv)(B)  RPS ACTUATION - CRITICA|                             |
|AESF 50.72(b)(3)(iv)(A)  VALID SPECIF SYS ACTUAT|                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     M/R        Y       100      Power Operation  |0        Hot Standby      |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| MANUAL REACTOR TRIP FOLLOWING CLOSURE OF A FEEDWATER ISOLATION VALVE
DURING  |
| SURVEILLANCE TESTING                                                         |
|                                                                              |
| The following text is a portion of a facsimile received from the licensee:   |
|                                                                              |
| "At 04:35 [CDT] on 06/14/2002, operators manually tripped the reactor        |
| following closure of feedwater isolation valve 2C during surveillance        |
| testing.  The cause of the feedwater isolation valve failure is unknown at   |
| this time.  Also, both source range nuclear instruments failed to energize   |
| following the reactor trip, but both extended range nuclear instruments are  |
| available.  The auxiliary feedwater system actuated as expected on steam     |
| generator low-low level."                                                    |
|                                                                              |
| "Did the rods fully insert?  yes                                             |
| Did steam bypass to the condenser or to atmosphere?  condenser               |
| Did any primary/secondary relief valves lift?  no                            |
| Any electrical bus transfer problems?  no                                    |
| State normal operating temperature and pressure (NOT/NOP)[:]  590 degrees    |
| 2235 psig                                                                    |
| Any significant TS LCOs entered?  no"                                        |
|                                                                              |
| The licensee stated that there was nothing unusual or misunderstood with the |
| exception of the cause of the feedwater isolation valve failure and the      |
| cause of the failure of both source range nuclear instruments to energize    |
| following the reactor trip.  All systems functioned as required with the     |
| same exceptions.                                                             |
|                                                                              |
| The licensee also stated that the unit is currently stable in Mode 3 (Hot    |
| Standby).  Normal charging and letdown, pressurizer heaters and sprays, and  |
| the reactor coolant pumps are currently being utilized for primary system    |
| level, pressure, and transport control.  Secondary steam is being dumped to  |
| the condenser, and auxiliary feedwater is supplying water to the steam       |
| generators.  Operators are in the process of transferring from auxiliary     |
| feedwater to main feedwater.  All engineered safety feature equipment and    |
| emergency core cooling systems are operable and available if needed.         |
|                                                                              |
| The licensee notified the NRC resident inspector.                            |
|                                                                              |
| * * * UPDATE ON 6/14/02 @ 2243 BY REDDIX TO GOULD * * *                      |
|                                                                              |
| Licensee reported that after further investigation it was determined that    |
| both source range instruments did energize as expected, however, after       |
| indicating some counts erratically, they decayed away to zero.  Both source  |
| range detectors are inoperable at this time.                                 |
|                                                                              |
| The NRC Resident Inspector was notified.                                     |
|                                                                              |
| Notified Reg 4 RDO(Gody)                                                     |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38992       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: NINE MILE POINT          REGION:  1  |NOTIFICATION DATE: 06/14/2002|
|    UNIT:  [] [2] []                 STATE:  NY |NOTIFICATION TIME: 11:24[EDT]|
|   RXTYPE: [1] GE-2,[2] GE-5                    |EVENT DATE:        06/13/2002|
+------------------------------------------------+EVENT TIME:        11:30[EDT]|
| NRC NOTIFIED BY:  DOUG RICHARDSON              |LAST UPDATE DATE:  06/14/2002|
|  HQ OPS OFFICER:  RICH LAURA                   +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |LAWRENCE DOERFLEIN   R1      |
|10 CFR SECTION:                                 |JOHN DAVIDSON        IAT     |
|NONR                     OTHER UNSPEC REQMNT    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| 24 HOUR REPORT ON LICENSE CONDITION 2F                                       |
|                                                                              |
| " At 1130 hours on 6/13/02 it was discovered that the Safety Relief Valve    |
| (SRV) Position Indication Channel for one of the SRVs controlled from the    |
| Remote Shutdown Panel was inoperable. The inoperability was due to both      |
| alarm card inhibit switches for associated acoustic monitoring channel being |
| found to be in the inhibit  position. These switches are normally in the     |
| "alarm"  position. With the switches in the "inhibit" position the SRV       |
| position indication from a high vibration condition would not provide an     |
| open position indication for the SRV in the Control Room or at the Remote    |
| Shutdown Panel. Immediate Action was to return the switches to the  alarm    |
| position and all other SRV acoustic monitoring switches were verified to be  |
| in the correct "alarm" position.                                             |
|                                                                              |
| "Technical Specification LCO 3.3.3.2 requires that the Remote Shutdown       |
| System Functions shall be OPERABLE. With this channel inoperable, Required   |
| Actions require restoration to OPERABLE status within 30 days OR placing the |
| Unit in Mode 3 within the following 12 hours. Since the potential exists     |
| that this condition has existed in excess of the 30-day requirement this     |
| event may be considered a Condition Prohibited by Technical Specifications.  |
|                                                                              |
| "This report is being made in accordance with Section 2F of Operating        |
| License NPF-69 for Nine-Mile Point Unit 2. Section 2F requires that the      |
| initial notification of a violation of any requirement contained in Section  |
| 2C to the Operating License (License Conditions) be reported to the NRC      |
| Operations Center via the Emergency Notification System within 24 hours with |
| written follow-up with 30 days. License Condition 2C requires that Nine Mile |
| Point Nuclear Station, LLC shall operate the facility in accordance with the |
| Technical Specifications."                                                   |
|                                                                              |
| The NRC Resident Inspector has been notified.                                |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38993       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: COOK                     REGION:  3  |NOTIFICATION DATE: 06/14/2002|
|    UNIT:  [1] [] []                 STATE:  MI |NOTIFICATION TIME: 17:14[EDT]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        06/14/2002|
+------------------------------------------------+EVENT TIME:        14:43[EDT]|
| NRC NOTIFIED BY:  MAY                          |LAST UPDATE DATE:  06/14/2002|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |JAMES CREED          R3      |
|10 CFR SECTION:                                 |                             |
|ARPS 50.72(b)(2)(iv)(B)  RPS ACTUATION - CRITICA|                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     M/R        Y       88       Power Operation  |0        Hot Standby      |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| REACTOR MANUALLY TRIPPED FROM 88% POWER DUE TO LOSS OF THE EAST MAIN
FEED    |
| PUMP ON LOW CONDENSER VACUUM                                                 |
|                                                                              |
| At 1443 the unit one reactor was manually tripped from 88% reactor power due |
| to the loss of the East Main Feedwater pump on low condenser vacuum.  Loss   |
| of East Main Feedwater Pump Condenser Vacuum occurred during the start of    |
| #13 Main Circulating Water Pump.  It is believed that this was caused by     |
| high differential pressure across the feed pump condenser and it appeared    |
| that the circulating water pump transferred some debris from the forebay     |
| into the condenser resulting in the loss of condenser vacuum, but this       |
| incident is still under investigation.                                       |
|                                                                              |
| All rods fully inserted, no ECCS injection and no safety relief valves       |
| lifted.                                                                      |
|                                                                              |
| Plant is currently stable in Mode 3. All plant equipment functioned as       |
| designed. Event Investigation is currently in progress.                      |
|                                                                              |
| The NRC Resident Inspector was notified.                                     |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38995       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: HATCH                    REGION:  2  |NOTIFICATION DATE: 06/15/2002|
|    UNIT:  [1] [2] []                STATE:  GA |NOTIFICATION TIME: 14:54[EDT]|
|   RXTYPE: [1] GE-4,[2] GE-4                    |EVENT DATE:        06/15/2002|
+------------------------------------------------+EVENT TIME:        08:30[EDT]|
| NRC NOTIFIED BY:  WATTS                        |LAST UPDATE DATE:  06/15/2002|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |KERRY LANDIS         R2      |
|10 CFR SECTION:                                 |                             |
|HFIT 26.73               FITNESS FOR DUTY       |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| FITNESS-FOR-DUTY QUESTIONED DUE TO FAILURE OF ALCOHOL TEST                   |
|                                                                              |
| COMPENSATORY MEASURES TAKEN                                                  |
|                                                                              |
| THE RESIDENT INSPECTOR WAS NOTIFIED                                          |
|                                                                              |
| Refer to HOO for additional details                                          |
+------------------------------------------------------------------------------+