Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for June 12, 2002

                         
                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           06/11/2002 - 06/12/2002

                              ** EVENT NUMBERS **

38972  38973  38978  

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   38972       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  ARKANSAS DEPARTMENT OF HEALTH        |NOTIFICATION DATE:
06/07/2002|
|LICENSEE:  ALBEMARLE CORPORATION                |NOTIFICATION TIME: 17:07[EDT]|
|    CITY:  MAGNOLIA                 REGION:  4  |EVENT DATE:        06/06/2002|
|  COUNTY:                            STATE:  AR |EVENT TIME:             [CDT]|
|LICENSE#:  ARK-717-BP            AGREEMENT:  Y  |LAST UPDATE DATE:  06/07/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |JOHN PELLET          R4      |
|                                                |THOMAS ESSIG         NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  JARED THOMPSON               |                             |
|  HQ OPS OFFICER:  FANGIE JONES                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT - SOURCE NOT ATTACHED TO SOURCE ROD                   |
|                                                                              |
| "On June 6, 2002 at 4:30 p.m. the Arkansas Department of Health was notified |
| by Albemarle Corporation in Magnolia, Arkansas that a fixed density gauge    |
| source had been damaged. Albemarle has Arkansas Radioactive Material License |
| ARK-717-BP-11-99. The device is a Ronan Engineering Company Model SA-15      |
| containing two 5 millicuries sources of Cesium-137. The device was locked    |
| out on June 3, 2002. On June 6, 2002 while the source housing was being      |
| adjusted it was noted that the source rod was in a different configuration.  |
| Radiation surveys were performed and it appeared that one of the 5           |
| millicuries sources was not attached to the source rod. The immediate area   |
| was secured and access has been restricted. Albemarle has contacted a        |
| consultant to assist in retrieval and packaging of the source for return to  |
| the manufacturer.                                                            |
|                                                                              |
| "The Department has sent two inspectors to the facility to investigate and   |
| assess the Incident on June 7, 2002. It appears that there may have been     |
| personnel radiation exposure due to this incident. This incident is under    |
| investigation."                                                              |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   38973       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  SC DIV OF HEALTH & ENV CONTROL       |NOTIFICATION DATE: 06/08/2002|
|LICENSEE:  ISOMEDIX CORPORATIONS                |NOTIFICATION TIME: 13:50[EDT]|
|    CITY:  SPARTANBURG              REGION:  2  |EVENT DATE:        06/07/2002|
|  COUNTY:                            STATE:  SC |EVENT TIME:        21:15[EDT]|
|LICENSE#:  267                   AGREEMENT:  Y  |LAST UPDATE DATE:  06/08/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |BRIAN BONSER         R2      |
|                                                |THOMAS ESSIG         NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  JAMES PETERSON               |                             |
|  HQ OPS OFFICER:  FANGIE JONES                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT - EMPLOYEE DEATH DUE TO NONNUCLEAR ACCIDENT     
     |
|                                                                              |
| With the source in the stored position, an employee of Isomedix Operations,  |
| entered the sterilization chamber of the irradiator to try freeing some      |
| jammed product carriers.  The employee was killed when his head was caught   |
| between the carriers as they moved together.                                 |
|                                                                              |
| This report is made as a conservative measure as this was not nuclear        |
| related, but occurred at a licensee's facility.                              |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38978       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: FT CALHOUN               REGION:  4  |NOTIFICATION DATE: 06/11/2002|
|    UNIT:  [1] [] []                 STATE:  NE |NOTIFICATION TIME: 00:26[EDT]|
|   RXTYPE: [1] CE                               |EVENT DATE:        06/10/2002|
+------------------------------------------------+EVENT TIME:        21:20[CDT]|
| NRC NOTIFIED BY:  RICH LOWERY                  |LAST UPDATE DATE:  06/11/2002|
|  HQ OPS OFFICER:  JOHN MacKINNON               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |ANTHONY GODY         R4      |
|10 CFR SECTION:                                 |                             |
|NONR                     OTHER UNSPEC REQMNT    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| BUS GROUND ON HOUSE SERVICE TRANSFORMER 4160V VITAL BUS TRANSFORMER   
      |
|                                                                              |
| At 2120 CT Ft. Calhoun Station control room received an alarm indicating a   |
| T1A3 4160V Bus Ground on house service transformer 4160V vital bus 1A3       |
| transformer.  Licensee referenced ARP and plant AOP's 31 and 32, for all     |
| 4160V buses fed from 22KV and Loss of 4160V bus power.  Subsequent securing  |
| of possible 4160V bus loads did not isolate the ground.  Subsequently        |
| transferred 4160V bus 1A3 feed from 4160V transformer T1A3 to 22KV           |
| Transformer T1A1.  Alarm and ground indications went away upon transfer.     |
| Per Technical Specification 2.7.(2)b Nuclear Regulatory Commission           |
| Operations Control Center shall be notified within 4 hours of transformer    |
| inoperability.  System Engineering and Electrical Support Staff are on site  |
| investigating. Plant is in a severe thunderstorm warning until 2300 CT.      |
| Diesel operability has been verified.                                        |
|                                                                              |
| The NRC Resident Inspector was notified of this event by the licensee.       |
+------------------------------------------------------------------------------+