Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for June 7, 2002

                         
                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           06/06/2002 - 06/07/2002

                              ** EVENT NUMBERS **

38955  38967  38968  38969  

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   38955       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  ARIZONA RADIATION REGULATORY AGENCY  |NOTIFICATION DATE:
05/31/2002|
|LICENSEE:  CONSTRUCTION INSPECTION AND TESTING  |NOTIFICATION TIME:
13:42[EDT]|
|    CITY:  TEMPE                    REGION:  4  |EVENT DATE:        05/31/2002|
|  COUNTY:                            STATE:  AZ |EVENT TIME:        09:30[MST]|
|LICENSE#:  7-98                  AGREEMENT:  Y  |LAST UPDATE DATE:  06/04/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |GARY SANBORN         R4      |
|                                                |FRED BROWN           NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  WILLIAM A. WRIGHT (fax)      |                             |
|  HQ OPS OFFICER:  MIKE NORRIS                  |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| STOLEN TROXLER MOISTURE/DENSITY GAUGE                                        |
|                                                                              |
| "Description of event: The licensee reported the loss of a Troxler           |
| moisture/density gauge and company truck when a technician failed to report  |
| to a designated job site. The gauge is a Troxler Model 3440, serial number   |
| 21935. It contains approximately 8 millicuries of Cesium 137 (source serial  |
| number 75-3524) and approximately 40 millicuries of Americium-Beryllium      |
| (source serial number 47-17271). The company vehicle is a 1999 white Ford    |
| F-150 extended cab pickup, company number 50, Arizona license [ ]. The Tempe |
| police have been notified and are investigating. The company is offering a   |
| $250 reward for information leading to the return of the gauge and truck.    |
|                                                                              |
| "The U.S. NRC, FBI, Mexico, and the states of Colorado, Nevada, Utah, New    |
| Mexico and California are being informed of this incident."                  |
|                                                                              |
| * * * UPDATE ON 6/4/02 BY WRIGHT (BY FAX) TO GOULD * * *                     |
|                                                                              |
| The gauge and truck have been recovered.                                     |
|                                                                              |
| The FBI, Mexico and the states of Colorado, Nevada, Utah, New Mexico and     |
| California were informed.                                                    |
|                                                                              |
| Notified Reg 4 RDO (Pellet), NMSS (Brown), IAT (Davidson)                    |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38967       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: COOK                     REGION:  3  |NOTIFICATION DATE: 06/06/2002|
|    UNIT:  [1] [] []                 STATE:  MI |NOTIFICATION TIME: 02:51[EDT]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        06/05/2002|
+------------------------------------------------+EVENT TIME:        23:00[EDT]|
| NRC NOTIFIED BY:  DUANE COBB                   |LAST UPDATE DATE:  06/06/2002|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          UNUSUAL EVENT         |JAMES CREED          R3      |
|10 CFR SECTION:                                 |STUART RICHARDS      NRR     |
|AAEC 50.72(a) (1) (i)    EMERGENCY DECLARED     |JOSEPH HOLONICH      IRO     |
|                                                |DEPUY                FEMA    |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Hot Shutdown     |0        Hot Shutdown     |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| UNIT 1 DECLARED AN UNUSUAL EVENT DUE TO RCS LEAKAGE > 25 GPM DURING         
|
| SURVEILLANCE TESTING                                                         |
|                                                                              |
| "D.C. Cook Unit One declares entry and exit of an Unusual Event due to       |
| Reactor Coolant System leakage of greater than 25 gallons per minute. On     |
| June 5 @ 23:00 while performing an 18 month surveillance [1-IHP-4030-102-017 |
| 'Pressurizer PORV/Actuation Channel Calibration with Valve Operation'] on    |
| the Pressurizer Power Operated Relief Valves (PORVs) an unblocked PORV       |
| lifted and discharged to the Pressure Relief Tank (PRT) for approximately 15 |
| seconds. This lifting discharged approximately 100 gallons to the PRT. The   |
| Initiating Condition for this Unusual Event is Reactor Coolant System        |
| leakage greater than 25 gallons per minute.                                  |
|                                                                              |
| "The plant is and was in Mode 4. Conditions remain stable after manual       |
| isolation of the PORV with the Control Switch of the Block Valve by the      |
| assisting Reactor Operator."                                                 |
|                                                                              |
| The licensee attributed this occurrence to the recently revised procedure    |
| identified above which did not address blocking the other PORVs during       |
| testing.  The licensee informed state and local agencies and the NRC         |
| Resident Inspector.                                                          |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Other Nuclear Material                           |Event Number:   38968       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  BJ SERVICES COMPANY                  |NOTIFICATION DATE: 06/06/2002|
|LICENSEE:  BJ SERVICES COMPANY                  |NOTIFICATION TIME: 10:57[EDT]|
|    CITY:  TOMBALL                  REGION:  4  |EVENT DATE:        06/06/2002|
|  COUNTY:                            STATE:  TX |EVENT TIME:             [CDT]|
|LICENSE#:                        AGREEMENT:  Y  |LAST UPDATE DATE:  06/06/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |ELMO COLLINS         R4      |
|                                                |FRED BROWN           NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  CHARLOTTE BELLON             |                             |
|  HQ OPS OFFICER:  STEVE SANDIN                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|BLO1 20.2201(a)(1)(i)    LOST/STOLEN LNM>1000X  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| GENERAL LICENSE CESIUM-137 SOURCE COULD NOT BE ACCOUNTED FOR                 |
|                                                                              |
| BJ Services, an oil field service company, determined that a general         |
| licensed source could not be located.  The source,  250 mCi Cs-137 sealed in |
| special form manufactured circa 1984, was installed in a Kay Ray Model 7063  |
| instrument, S/N 28820, used for slurry density measurements.  The last       |
| recorded location was Rock Springs, WY, on September 8, 1990 for a leak      |
| test.  The instrument was then owned by Western Company which was acquired   |
| by BJ Services in 1995.  BJ Services has discussed this incident with        |
| R4(Donovan) and will continue their investigation.                           |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38969       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: COMANCHE PEAK            REGION:  4  |NOTIFICATION DATE: 06/06/2002|
|    UNIT:  [] [2] []                 STATE:  TX |NOTIFICATION TIME: 22:21[EDT]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        06/06/2002|
+------------------------------------------------+EVENT TIME:        19:24[CDT]|
| NRC NOTIFIED BY:  LEON NEAT                    |LAST UPDATE DATE:  06/06/2002|
|  HQ OPS OFFICER:  FANGIE JONES                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |ELMO COLLINS         R4      |
|10 CFR SECTION:                                 |NADER MAMISH         R4      |
|ARPS 50.72(b)(2)(iv)(B)  RPS ACTUATION - CRITICA|                             |
|AESF 50.72(b)(3)(iv)(A)  VALID SPECIF SYS ACTUAT|                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     A/R        Y       100      Power Operation  |0        Hot Standby      |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| REACTOR TRIP CAUSED BY TURBINE TRIP                                          |
|                                                                              |
| The reactor tripped due to a turbine trip due to a main generator trip       |
| caused by a high vibration on the main generator primary water pump shaft.   |
| All systems functioned properly.  The plant is stable in Mode 3 with steam   |
| generator level being maintained with auxiliary feedwater (started           |
| automatically on low steam generator level) and excess heat being removed    |
| via the steam bypassed to the main condenser.                                |
|                                                                              |
| Primary water pump vibration trip is a 2 out of 2 channel coincidence.       |
| There was no indication of high vibration on the plant recorder.  At the     |
| time of the trip, an investigation was ongoing on one of the channels that   |
| was in alarm.  An investigation continues into the sensors and circuits      |
| associated with the high vibration trip.  The plant will remain in Mode 3    |
| until the problem is identified and corrected.                               |
|                                                                              |
| The licensee notified the NRC Resident Inspector.                            |
+------------------------------------------------------------------------------+