Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for April 30, 2002

                         
                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           04/29/2002 - 04/30/2002

                              ** EVENT NUMBERS **

38879  38881  

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   38879       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  OHIO BUREAU OF RADIATION PROTECTION  |NOTIFICATION DATE: 04/26/2002|
|LICENSEE:  RIVERSIDE METHODIST HOSPITAL         |NOTIFICATION TIME: 13:06[EDT]|
|    CITY:  COLUMBUS                 REGION:  3  |EVENT DATE:       04/23/2002 |
|  COUNTY:                            STATE:  OH |EVENT TIME:            [EDT] |
|LICENSE#:  02120-250070          AGREEMENT:  Y  |LAST UPDATE DATE: 04/26/2002 |
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON         ORGANIZATION  |
|                                                |JOHN JACOBSON        R3      |
|                                                |DOUGLAS BROADDUS    NMSS     |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  MARK LIGHT                   |                             |
|  HQ OPS OFFICER:  RICH LAURA                   |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                  
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT OF A MEDICAL MISADMINISTRATION                        |
|                                                                              |
| A medical misadministration occurred on April 23, 2002 that resulted in the  |
| patient receiving a 36% overdose (i.e., 10.9 gray vice 8 gray) during        |
| brachytherapy to treat coronary vessels.  The isotope being used for the     |
| treatment is IR-192. The error was discovered on April 25, 2002 when the     |
| hospital was setting up to treat another patient.  Specifically, a wrong     |
| decay table was used in the calculations.  No adverse effect on the patient  |
| was anticipated.  The patient has been notified.                             |
|                                                                              |
| The State reported that RIII (K. NULL) has been notified.                    |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38881       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: LASALLE                  REGION:  3  |NOTIFICATION DATE:04/27/2002 |
|    UNIT:  [1] [2] []                STATE:  IL |NOTIFICATION TIME:15:51[EDT] |
|   RXTYPE: [1] GE-5,[2] GE-5                    |EVENT DATE:        4/27/2002 |
+------------------------------------------------+EVENT TIME:        11:40[CDT]|
| NRC NOTIFIED BY:  GRANLUND                     |LAST UPDATE DATE:  04/29/2002|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON         ORGANIZATION  |
|EMERGENCY CLASS:          NON EMERGENCY         |JOHN JACOBSON        R3      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RXMODE    |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION REGARDING A BOATING ACCIDENT ON THE SITE'S COOLING      |
| LAKE                                                                         |
|                                                                              |
| On April 27, 2002, at 1140 CDT, the Main Control Room received a report from |
| Outside Rounds Operator that a fishing boat had capsized on the station      |
| cooling lake and that two individuals aboard the capsized boat were at the   |
| Wastewater Treatment Facility after swimming ashore.  One individual aboard  |
| the capsized boat remains missing.  Currently, the boat has been recovered,  |
| but after a search of the lake perimeter, the third individual remains       |
| missing.  The Ottawa Search and Rescue Team was on site to perform rescue    |
| operations but has determined that lake conditions are too rough to perform  |
| a water based rescue operation.  State Police and LaSalle County Sheriff     |
| have been notified.  Marseilles and Seneca Fire Departments are coming to    |
| the site to assist in a ground search.   Department of Natural Resources     |
| officials are also assisting with the missing person search.                 |
|                                                                              |
| The NRC Resident Inspector was notified.                                     |
|                                                                              |
| ***** UPDATE FROM LARRY BLUNK TO LEIGH TROCINE AT 1245 EDT ON 04/29/02       |
| *****                                                                        |
|                                                                              |
| At approximately 0940 CDT on 04/29/02, the body of the individual missing    |
| from the boating accident was found in LaSalle's cooling lake.  The LaSalle  |
| County Coroner responded to the scene and took possession of the body. All   |
| parties subsequently left the vicinity of the station.                       |
|                                                                              |
| The licensee notified the NRC resident inspector.  The NRC operations        |
| officer notified the R3DO (Brent Clayton).                                   |
+------------------------------------------------------------------------------+


Page Last Reviewed/Updated Wednesday, March 24, 2021