Skip to main content

Alert

Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for April 25, 2002

                         
                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           04/24/2002 - 04/25/2002

                              ** EVENT NUMBERS **

38761  

!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED  !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38761       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: VOGTLE                   REGION:  2  |NOTIFICATION DATE: 03/12/2002|
|    UNIT:  [1] [] []                 STATE:  GA |NOTIFICATION TIME: 14:50[EST]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        03/12/2002|
+------------------------------------------------+EVENT TIME:        08:30[EST]|
| NRC NOTIFIED BY:  CECIL WILLIAMS               |LAST UPDATE DATE:  04/24/2002|
|  HQ OPS OFFICER:  GERRY WAIG                   +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |MARK LESSER          R2      |
|10 CFR SECTION:                                 |                             |
|AUNA 50.72(b)(3)(ii)(B)  UNANALYZED CONDITION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Cold Shutdown    |0        Cold Shutdown    |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| UNANALYZED CONDITION - SI MINIFLOW LINE VALVE INTERLOCK MIS-WIRED            |
|                                                                              |
| "In the analysis for certain design bases accidents, credit is taken for a   |
| recirculation mode of operation that ensures continued cooling to the        |
| reactor core following an injection mode. During the current Unit 1          |
| refueling outage, it was found that a safety injection (SI) miniflow line    |
| valve (1HV-8813) interlock was mis-wired. The interlock wiring should have   |
| allowed a second valve (1HV-8804B) to be opened during switchover from       |
| injection mode to recirculation mode once 1HV-8813 has been closed but would |
| not. This wiring error was subsequently corrected. 1HV-8804B is opened to    |
| provide a suction source from the discharge of the Train B residual heat     |
| removal (RHR) pump to the suction of the SI pumps. 1HV-8804B must open for   |
| recirculation to begin if the opposite train is unavailable. A review has    |
| found that this mis-wiring has existed since at least 1996.                  |
|                                                                              |
| "Based on preliminary evaluation, on 3-12-2002, at 0830 EST, we concluded    |
| that this may represent an unanalyzed condition that significantly degrades  |
| plant safety and is reportable per 10 CFR 50.72 (b)(3)(ii)(B). Further       |
| evaluation is being performed to determine the significance of the           |
| mis-wiring."                                                                 |
|                                                                              |
| The NRC Resident was notified by the licensee.                               |
|                                                                              |
| ***** RETRACTION FROM JOHN WILLIAMS TO LEIGH TROCINE AT 1047 EDT ON 04/25/02
|
| *****                                                                        |
|                                                                              |
| The following text is a portion of a facsimile received from the licensee:   |
|                                                                              |
| "RETRACTION - Further review of the event reported on 03/12/02 via           |
| Notification #38761, and described [above], has concluded that it is not a   |
| condition that significantly degrades plant safety.   It is hereby           |
| retracted."                                                                  |
|                                                                              |
| The licensee notified the NRC resident inspector and plans to make a 60-day  |
| report.  The NRC operations officer notified the R2DO (Ann Boland).          |
+------------------------------------------------------------------------------+


Page Last Reviewed/Updated Thursday, March 25, 2021

Page Last Reviewed/Updated Thursday, March 25, 2021