The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.
Event Notification Report for April 23, 2002
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
04/22/2002 - 04/23/2002
** EVENT NUMBERS **
38035 38870 38871 38872 38873
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 38035 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: BOWSER-MORNER INC |NOTIFICATION DATE: 05/29/2001|
|LICENSEE: BOWSER-MORNER INC |NOTIFICATION TIME: 10:30[EDT]|
| CITY: TOLEDO REGION: 3 |EVENT DATE: 05/27/2001|
| COUNTY: STATE: OH |EVENT TIME: 09:30[EDT]|
|LICENSE#: 34-17390-02 AGREEMENT: Y |LAST UPDATE DATE: 04/22/2002|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |MARK RING REG3 |
| |LARRY CAMPER NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: ALLEN | |
| HQ OPS OFFICER: CHAUNCEY GOULD | |
+------------------------------------------------+ |
|EMERGENCY CLASS: NON EMERGENCY | |
|10 CFR SECTION: | |
|BAB1 20.2201(a)(1)(i) LOST/STOLEN LNM>1000X | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| TROXLER GAUGE STOLEN FROM COMPANY TRUCK AT RESIDENCE |
| |
| Sometime between 0200-0930 hours on 5/27 a company truck was broken into |
| removing a Troxler gauge and it's case. The gauge was properly stowed and |
| it's case attached to the truck bed using a chain and lock. The truck was |
| parked overnight at the residence of the employee at 402 Lochmoor Drive in |
| Temperance, MI. The stolen Troxler is a model 3401B, S/N 13442, whose last |
| measured activity on 4/30/01 was 5.6 mCi Cs-137 and 39 mCi Am-241/Be. The |
| Monroe County Sheriffs Department in Temperance, MI and Ohio Department of |
| Health were both notified. The licensee plans on issuing a press release. |
| |
| ****UPDATE ON 04/22/02 AT 1647 ET BY ALLEN TAKEN BY MACKINNON**** |
| |
| The above mentioned gauge was recovered this morning by the City of Bryan |
| Local Emergency Management Agency. The gauge was found this morning in a |
| ditch along side a highway still in its yellow case by some children. The |
| source handle of the gauge was still locked and the only thing wrong was |
| that the lock to the case had been broken off. The children that had found |
| the gauge in its case called 911 and it was recovered by local law |
| enforcement agency and given to the City of Bryan local Emergency Management |
| Agency. The licensee was notified and picked up the gauge this morning. |
| The gauge was leak tested and was found to be in perfect condition. R3DO |
| (Jacobson) & NMSS EO (Wayne Hodges) notified. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 38870 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SUSQUEHANNA REGION: 1 |NOTIFICATION DATE: 04/22/2002|
| UNIT: [1] [] [] STATE: PA |NOTIFICATION TIME: 02:43[EDT]|
| RXTYPE: [1] GE-4,[2] GE-4 |EVENT DATE: 04/22/2002|
+------------------------------------------------+EVENT TIME: 01:15[EDT]|
| NRC NOTIFIED BY: ART FINCH |LAST UPDATE DATE: 04/22/2002|
| HQ OPS OFFICER: MIKE NORRIS +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |JOHN ROGGE R1 |
|10 CFR SECTION: | |
|ARPS 50.72(b)(2)(iv)(B) RPS ACTUATION - CRITICA| |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 M/R Y 16 Power Operation |0 Hot Shutdown |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| MANUAL RPS ACTUATION |
| |
| "Susquehanna Unit 1 was at 20% power and in the process of preparing to |
| further increase power following a Refueling and Inspection Outage. At 0016 |
| on 4/22/02, the B Reactor Recirculation Pump tripped for an unexplained |
| reason. During a review of the plant response to the transient, it was |
| discovered that the unit was operating to the left of the expected Power to |
| Flow curve. There was no indication of power flux oscillations from the |
| nuclear instrumentation, but no guidance was available on how to respond to |
| this condition. Reactor Engineering and Operations Management were contacted |
| and it was decided to manually scram the unit. At 0115 the Mode Switch was |
| taken to Shutdown and all control rods inserted. This was an unplanned RPS |
| Actuation and in accordance with 10 CFR 50.72(b)(2)(iv)(B) requires a |
| four-hour ENS Notification. Reactor water level dropped below level 3 which |
| is expected during a scram, feedwater level control responded to return |
| level to normal and all level 3 isolations went to completion. There were no |
| ECCS initiations, no challenges to containment, and no indication of |
| radiation releases. Operations is currently performing a controlled cooldown |
| to mode 4, an investigation into the cause of the recirc pump trip is |
| ongoing." |
| |
| The NRC Resident Inspector has been notified. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Other Nuclear Material |Event Number: 38871 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: SEIMENS MEDICAL SOLUTIONS USA, INC |NOTIFICATION DATE:
04/22/2002|
|LICENSEE: SEIMENS MEDICAL SOLUTIONS USA, INC |NOTIFICATION TIME: 11:03[EDT]|
| CITY: ISELIN REGION: 1 |EVENT DATE: 04/20/2002|
| COUNTY: MIDDLESEX STATE: NJ |EVENT TIME: 02:00[EDT]|
|LICENSE#: 29-32349-01 AGREEMENT: N |LAST UPDATE DATE: 04/22/2002|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |CLIFFORD ANDERSON R1 |
| |MARK SHAFFER R4 |
+------------------------------------------------+CHARLIE COX NMSS |
| NRC NOTIFIED BY: ROBERT F. WILEY | |
| HQ OPS OFFICER: MIKE NORRIS | |
+------------------------------------------------+ |
|EMERGENCY CLASS: NON EMERGENCY | |
|10 CFR SECTION: | |
|BAB1 20.2201(a)(1)(i) LOST/STOLEN LNM>1000X | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| LOSS/STOLEN NUCLEAR LICENSED MATERIAL >1000X |
| |
| Two calibration sources were stolen from a rental car in Oahu, Hawaii on |
| 4/19/02. The sources, 2 millicuries of Am-241 and 2 millicuries of Co-57, |
| were in tungsten shielded containers with screwed on lead caps. The sources |
| were in a locked tool box, which was in the locked trunk. The thief pulled |
| out the driver door lock, pried open the glove box and opened the trunk. |
| The source numbers and dates were as follows: Am-241, #0191LX, 8-4-89 and |
| Co-57, #5971 LC, 10-13-00. The Kaneohe Police Department was notified, |
| report # 02-145893. Ads will be placed in the local newspapers. Licensee |
| indicated that there were no measurable dose rates on the outside of the |
| shielded container. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 38872 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: COOK REGION: 3 |NOTIFICATION DATE: 04/22/2002|
| UNIT: [1] [2] [] STATE: MI |NOTIFICATION TIME: 13:17[EDT]|
| RXTYPE: [1] W-4-LP,[2] W-4-LP |EVENT DATE: 04/22/2002|
+------------------------------------------------+EVENT TIME: 06:00[EDT]|
| NRC NOTIFIED BY: DEAN BRUCK |LAST UPDATE DATE: 04/22/2002|
| HQ OPS OFFICER: JOHN MacKINNON +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |JOHN JACOBSON R3 |
|10 CFR SECTION: |JIM WHITNEY NMSS |
|NINF INFORMATION ONLY | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
|2 N Y 100 Power Operation |100 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| MICHIGAN STATE POLICE AT DC COOK PLANT ENTRANCE. |
| |
| |
| The following is a courtesy call regarding an event that occurred at the DC |
| Cook Nuclear Power Plant at 0600 on 4/22/02. The following has not been |
| issued as a Cook Plant news release but it is believed that the news media |
| is already aware of this via other means. |
| |
| At 0600 on 4/22/02, Michigan State Police (MSP) arrived at the Cook Plant |
| main entrance. MSP told Cook Plant Security that they were waiting for an |
| individual known to work at Cook to show up. MSP had previous encounters |
| with this individual and knew this person had concealed weapons permit, was |
| known to carry a weapon in the car and had been previously advised by MSP to |
| not carry a weapon on Cook property. |
| |
| When the individual, a contractor, arrived, Cook Plant Security personnel |
| asked him if had a weapon in his car. He stated that he did not, having |
| stashed it offsite on the highway. At this point the MSP advised him that |
| he would take them to the location of the weapon. About 15 minutes later |
| MSP and the individual returned, with MSP in possession of the weapon. MSP |
| stated that they would retain possession of the weapon pending further |
| investigation. Having no other reasons to deny access, the individual was |
| allowed on site. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 38873 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: CALVERT CLIFFS REGION: 1 |NOTIFICATION DATE: 04/22/2002|
| UNIT: [1] [2] [] STATE: MD |NOTIFICATION TIME: 13:36[EDT]|
| RXTYPE: [1] CE,[2] CE |EVENT DATE: 04/22/2002|
+------------------------------------------------+EVENT TIME: 12:05[EDT]|
| NRC NOTIFIED BY: D. FRYE |LAST UPDATE DATE: 04/22/2002|
| HQ OPS OFFICER: JOHN MacKINNON +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |CLIFFORD ANDERSON R1 |
|10 CFR SECTION: | |
|APRE 50.72(b)(2)(xi) OFFSITE NOTIFICATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N N 0 Refueling |0 Refueling |
|2 N Y 100 Power Operation |100 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| EMERGENCY SIRENS ACTUATED DURING A SILENT TEST |
| |
| |
| Inadvertent Emergency Response Siren actuation occurred in Calvert County |
| during the weekly silent test. All 49 sirens sounded for approx. 15 |
| seconds. |
| |
| |
| The NRC Resident Inspector was notified of this event by the licensee. |
+------------------------------------------------------------------------------+
Page Last Reviewed/Updated Wednesday, March 24, 2021
Page Last Reviewed/Updated Wednesday, March 24, 2021