Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for April 9, 2002

                         
                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           04/08/2002 - 04/09/2002

                              ** EVENT NUMBERS **

38818  38839  38840  38841  38842  

!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED  !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38818       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SUSQUEHANNA              REGION:  1  |NOTIFICATION DATE: 03/31/2002|
|    UNIT:  [1] [2] []                STATE:  PA |NOTIFICATION TIME: 05:32[EST]|
|   RXTYPE: [1] GE-4,[2] GE-4                    |EVENT DATE:        03/31/2002|
+------------------------------------------------+EVENT TIME:        04:10[EST]|
| NRC NOTIFIED BY:  GORDON ROBINSON              |LAST UPDATE DATE:  04/08/2002|
|  HQ OPS OFFICER:  FANGIE JONES                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |WILLIAM RULAND       R1      |
|10 CFR SECTION:                                 |                             |
|AINA 50.72(b)(3)(v)(A)   POT UNABLE TO SAFE SD  |                             |
|AINB 50.72(b)(3)(v)(B)   POT RHR INOP           |                             |
|AINC 50.72(b)(3)(v)(C)   POT UNCNTRL RAD REL    |                             |
|AIND 50.72(b)(3)(v)(D)   ACCIDENT MITIGATION    |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Cold Shutdown    |0        Cold Shutdown    |
|2     N          Y       87       Power Operation  |87       Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| DIESEL GENERATORS DECLARED INOPERABLE FOR SHORT TIME PERIOD                  |
|                                                                              |
| "During performance of 24 month Division 1 Diesel Generator LOCA/LOOP        |
| surveillance testing, two pump start timers failed to meet the required      |
| acceptance criteria. The A RHR Pump timer actuated at 3.72 seconds           |
| (criteria: 2.7 sec. to 3.6 sec) and the C ESW Pump timer actuated at 39.24   |
| seconds (criteria: 39.6 sec. to 48.4 sec). With failure of the timers proper |
| loading on the Diesel Generators is not assured, and they ['A' and 'C'] were |
| declared inoperable until the associated pump control breakers were opened.  |
| The Susquehanna safety analysis requires three operable Diesel Generators to |
| safely shutdown the plant. Therefore with only two operable Diesel           |
| Generators, the condition requires an 8 hr ENS notification in accordance    |
| with 10CFR50.72(b)(3)(v) and (vi)."                                          |
|                                                                              |
| With Unit 1 shutdown the 'A' RHR pump is not needed, but the 'C' ESW pump    |
| does need to be operable resulting in part of the 8 hour report.             |
|                                                                              |
| The licensee notified the NRC Resident Inspector.                            |
|                                                                              |
| * * * RETRACTED ON 04/08/2002 AT 1433 EDT BY GRANT FERNSLER TO GERRY WAIG * 
|
| * *                                                                          |
|                                                                              |
| "On 3/31/2002, Susquehanna LLC made an ENS notification per                  |
| 10CFR50.72(b)(3)(v) and (vi). The event was the result of two load sequence  |
| timers for separate diesel generators found outside of the allowable values. |
| The associated diesel generators were declared inoperable.                   |
|                                                                              |
| "Upon subsequent engineering review, it was determined that although the     |
| timers were not within the design specifications all equipment would have    |
| been able to perform its safety function, as evidenced by the emergency      |
| generators maintaining voltage and frequency, and the loads energizing and   |
| running during the testing. Additionally, the requirements of the Technical  |
| Specification Actions were followed for all inoperable equipment.            |
|                                                                              |
| With all equipment remaining capable of performing its design function, this |
| ENS Notification EN#38818 is retracted."                                     |
|                                                                              |
| "The NRC Resident Inspector was notified by the licensee.                    |
|                                                                              |
| The R1DO (Bradley Fewell) was notified by the Headquarters Operations        |
| Officer.                                                                     |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38839       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: COOPER                   REGION:  4  |NOTIFICATION DATE: 04/08/2002|
|    UNIT:  [1] [] []                 STATE:  NE |NOTIFICATION TIME: 11:03[EDT]|
|   RXTYPE: [1] GE-4                             |EVENT DATE:        04/08/2002|
+------------------------------------------------+EVENT TIME:        03:00[CDT]|
| NRC NOTIFIED BY:  WILLIAM GREEN                |LAST UPDATE DATE:  04/08/2002|
|  HQ OPS OFFICER:  MIKE NORRIS                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |BILL JONES           R4      |
|10 CFR SECTION:                                 |                             |
|ACOM 50.72(b)(3)(xiii)   LOSS COMM/ASMT/RESPONSE|                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| LOSS OF EMERGENCY PREPAREDNESS CAPABILITIES                                  |
|                                                                              |
| "At 0300 one of the two belts on the Emergency Outside AIR Fan (OAF-2) for   |
| the Technical Support Center (TSC) / Operations Support Center (OSC) was     |
| found broken.  The other fan belt appeared to be degrading rapidly.  The fan |
| was taken out of service.  OAF-2 provides outside air to the TSC / OSC that  |
| is filtered. Unavailability of this fan could prevent the use of the TSC /   |
| OSC in the event of a radiological release.                                  |
|                                                                              |
| "Station Procedure 5.7.7, activation of the TSC section 4, Evacuation of the |
| TSC, provides guidance for the evacuation of the TSC and the relocation of   |
| TSC personnel.  Station Procedure 5.7.8.1, Activation of the Alternate OSC,  |
| provides guidance for the evacuation of the OSC and the relocation of OSC    |
| personnel. In the event of an emergency that requires activation of the TSC  |
| / OSC, the TSC / OSC will be activated and atmospheric monitoring will be    |
| performed in accordance with existing station procedures. If conditions      |
| require the evacuation of the TSC / OSC, TSC / OSC personnel will be         |
| relocated in accordance with existing station procedures.                    |
|                                                                              |
| "Currently repairs to replace the belts on OAF-2 are underway. OAF-2 should  |
| be returned to service today."                                               |
|                                                                              |
| The NRC Resident Inspector has been notified.                                |
|                                                                              |
| * * * UPDATED ON 03/08/02 AT 1542 EDT BY WILLIAM GREEN TO GERRY WAIG * * *   |
|                                                                              |
| "At 1340 CDT OAF-2 was returned to service after a replacement of the        |
| damaged belts. The fan has been inspected by Maintenance and determined to   |
| be operating properly. Damage to belts appears to be from normal wear."      |
|                                                                              |
| The NRC Resident Inspector was notified by the licensee.                     |
|                                                                              |
| R4DO (Kriss Kennedy) was notified by the Headquarters Operations Officer.    |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38840       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: GINNA                    REGION:  1  |NOTIFICATION DATE: 04/08/2002|
|    UNIT:  [1] [] []                 STATE:  NY |NOTIFICATION TIME: 17:13[EDT]|
|   RXTYPE: [1] W-2-LP                           |EVENT DATE:        04/08/2002|
+------------------------------------------------+EVENT TIME:        10:52[EDT]|
| NRC NOTIFIED BY:  MIKE MICKLOW                 |LAST UPDATE DATE:  04/08/2002|
|  HQ OPS OFFICER:  GERRY WAIG                   +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |J. BRADLEY FEWELL    R1      |
|10 CFR SECTION:                                 |                             |
|ACOM 50.72(b)(3)(xiii)   LOSS COMM/ASMT/RESPONSE|                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Cold Shutdown    |0        Cold Shutdown    |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| UNSUCCESSFUL TEST OF THE SIREN SILENT TEST                                   |
|                                                                              |
| "During the siren silent test performed on 4-08-02 at the Cobbs Hill         |
| location, all sirens indicated failure to reply. A subsequent test was       |
| performed from the Monroe County 911 center. All sirens indicated failure to |
| reply. A single activation test on siren #1 in Monroe County was performed.  |
| The siren did not receive a signal to activate. Continuous radio traffic was |
| detected on the siren radio frequency. This prevented a signal from being    |
| received by the sirens. Wayne and Monroe County were notified to utilize     |
| route-alerting procedures in the event that notification to the public was   |
| necessary. A technician was dispatched with a radio signal detection         |
| instrument to determine the source of the radio traffic on thc siren         |
| frequency. Siren #22 in Monroe County was found to have a strong continuous  |
| active radio signal. Siren #22 was de-energized and the continuous radio     |
| signal stopped. Siren #22 is quarantined as part of a root cause             |
| investigation. Follow up testing is planned."                                |
|                                                                              |
| The NRC Resident Inspector was notified by the licensee.                     |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38841       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: MAINE YANKEE             REGION:  1  |NOTIFICATION DATE: 04/08/2002|
|    UNIT:  [1] [] []                 STATE:  ME |NOTIFICATION TIME: 18:15[EDT]|
|   RXTYPE: [1] CE                               |EVENT DATE:        04/08/2002|
+------------------------------------------------+EVENT TIME:        15:15[EDT]|
| NRC NOTIFIED BY:  TERRY WHITE                  |LAST UPDATE DATE:  04/08/2002|
|  HQ OPS OFFICER:  GERRY WAIG                   +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |J. BRADLEY FEWELL    R1      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Decommissioned   |0        Decommissioned   |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION OF FATALITY                                             |
|                                                                              |
| At 1300 EDT on 4/8/2002 a contract worker was transported from the site by   |
| ambulance to Mid Coast Hospital in Brunswick, Maine. Prior to being          |
| transported, the worker was treated by onsite EMT and other medical          |
| personnel. The worker was not working in a radioactive contaminated area and |
| was not contaminated at the time of the event. The licensee later learned    |
| that the worker died of an apparent heart attack. The licensee safety        |
| department reported the death to OSHA at 1515 EDT.                           |
|                                                                              |
| The licensee reported that R1 (Randy Ragland) has been notified of the       |
| event.                                                                       |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38842       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: FITZPATRICK              REGION:  1  |NOTIFICATION DATE: 04/08/2002|
|    UNIT:  [1] [] []                 STATE:  NY |NOTIFICATION TIME: 20:55[EDT]|
|   RXTYPE: [1] GE-4                             |EVENT DATE:        04/08/2002|
+------------------------------------------------+EVENT TIME:        19:07[EDT]|
| NRC NOTIFIED BY:  ROBERT THOMAS                |LAST UPDATE DATE:  04/08/2002|
|  HQ OPS OFFICER:  GERRY WAIG                   +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |J. BRADLEY FEWELL    R1      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION OF MINOR OIL SPILL                                      |
|                                                                              |
| "IAW [In Accordance With] AP-09.03, Oil Spill Prevention Control and         |
| Countermeasures Plan, reported to NYSDEC and USCG National Response Ctr [an] |
| oil spill in which oil and lubricant [less than 1 gallon] washed off a road  |
| sander during rain showers entered storm drain. Slight sheen observed at     |
| outfall for storm drains to Lake Ontario."                                   |
|                                                                              |
| The NRC Resident will be notified of the event by the licensee.              |
+------------------------------------------------------------------------------+