Event Notification Report for April 2, 2002
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
04/01/2002 - 04/02/2002
** EVENT NUMBERS **
38602 38819 38820 38821 38822
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 38602 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: CRYSTAL RIVER REGION: 2 |NOTIFICATION DATE: 01/01/2002|
| UNIT: [3] [] [] STATE: FL |NOTIFICATION TIME: 10:08[EST]|
| RXTYPE: [3] B&W-L-LP |EVENT DATE: 01/01/2002|
+------------------------------------------------+EVENT TIME: 09:19[EST]|
| NRC NOTIFIED BY: BILL BANDHAUER |LAST UPDATE DATE: 04/02/2002|
| HQ OPS OFFICER: FANGIE JONES +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |ANNE BOLAND R2 |
|10 CFR SECTION: | |
|APRE 50.72(b)(2)(xi) OFFSITE NOTIFICATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|3 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION DUE RESCUED SEA TURTLE |
| |
| EN #37902 started the biennial report period. |
| |
| On January 1, 2002 at 0919, a rescued sea turtle was identified as a green |
| sea turtle. This is the 62nd rescue of a live sea turtle at Crystal River |
| Unit 3 (CR-3) in this biennial period. Notification to the National Marine |
| Fisheries Service and the Florida Fish and Wildlife Conservation Commission. |
| |
| |
| The licensee intends to notify the NRC Resident Inspector. |
| |
| * * * UPDATE ON 1/05/02 @ 1002 BY RAWLS TO GOULD * * * |
| |
| On January 5, 2002, at 0720, a rescued sea turtle was identified as a |
| Loggerhead Sea Turtle. This is the 63rd rescue of a live sea turtle at |
| Crystal River Unit 3 (CR3) in this biennial period. This is reportable as a |
| 4-hour report under 10 CFR 50.72(b)(2)(xi) as this event is related to the |
| protection of the environment for which a notification to other government |
| agencies (National Marine Fisheries Service and Florida Fish and Wildlife |
| Conservation Commission) has been or will be made. |
| |
| The NRC Resident Inspector was notified. |
| |
| Reg 2 RDO (Decker) was notified. |
| |
| * * * UPDATE ON 01/09/02 @ 1107 EST BY ANDY BARNES TAKEN BY MACKINNON * * * |
| |
| On January 9, 2002, at 0838, a rescued sea turtle was identified as a Kemp's |
| Ridley Sea Turtle. This is the 64th rescue of a live turtle at Crystal River |
| Unit 3 (CR-3) in this biennial period. This is reportable as a 4-hour 10 CFR |
| 50.72 (b)(2)(xi) as this event is related to the protection of the |
| environment for which a notification to other government agencies (National |
| Marine Fisheries Service and Florida Fish and Wildlife Conservation |
| Commission) has been or will be made. |
| |
| The NRC Resident Inspector was notified. |
| |
| Reg 2 (Brian Bonser) was notified. |
| |
| * * * UPDATE ON 02/17/02 at 0940 EST BY RICKY RAWLS TO FANGIE JONES * * * |
| |
| "On February 17, 2002 at 0820, a rescued injured sea turtle was identified |
| as a Kemp's Ridley Sea Turtle. The injury will require transportation to |
| Clearwater Marine Science Center or Florida Fish and Wildlife Conservation |
| Refuge. The Injury appears to be from a boat propeller. This is the 65th |
| rescue of a live sea turtle at Crystal River Unit 3 (CR-3) in this biennial |
| period. This is Reportable as a 4-Hour Report under 10 CFR 50.72(b) (2) (xi) |
| as this event is related to the protection of the environment for which a |
| notification to other government agencies (National Marine Fisheries Service |
| and Florida Fish and Wildlife Conservation Commission) has been or will be |
| made. This Is an update to event 38602." |
| |
| The NRC Resident Inspector will be notified. R2DO (Stephen Cahill) has been |
| notified. |
| |
| * * * UPDATE ON 03/01/02 AT 1122 EST BY RICKY RAWLS TO GERRY WAIG * * * |
| |
| "On March 1, 2002 at 0952, a healthy rescued sea turtle was identified as a |
| Green Sea Turtle. This is the 66th rescue of a live sea turtle at Crystal |
| River Unit 3 (CR-3) in this biennial period. This is Reportable as a 4-Hour |
| Report under 10 CFR 50.72 (b) (2) (xi) as this event is related to the |
| protection of the environment for which a notification to other government |
| agencies (National Marine Fisheries Service and Florida Fish and Wildlife |
| Conservation Commission) has been or will be made. This is an update to |
| event 38602." |
| |
| The NRC Resident Inspector was notified. R2DO (Julian) was notified. |
| |
| * * * UPDATE ON 03/07/02 AT 1114 EST BY CHUCK MORRIS TO MIKE NORRIS * * * |
| |
| "On March 7, 2002 at 0835, two healthy sea turtles rescued at CR#3 were |
| identified as Green Sea Turtles. These are the 67th and 68th live sea turtle |
| rescues at the Crystal River Energy Complex in this biennial period. This is |
| Reportable as a 4-Hour Report under 10 CFR 50.72(b) (2) (xi) as this event |
| is related to the protection of the environment for which a notification to |
| other government agencies (National Marine Fisheries Service and Florida |
| Fish and Wildlife Conservation Commission) has been or will be made. This is |
| an update to event 38602." |
| |
| The NRC Resident Inspector was notified. R2DO (Henson) was notified. |
| |
| * * * UPDATE ON 04/02/02 at 0408 EST BY RICKY RAWLS TO FANGIE JONES * * * |
| |
| "On April 2, 2002 at 0236, two sea turtles previously rescued at CR#3 intake |
| area were identified by FPC Mariculture staff as Kemp Ridley Sea Turtles. |
| One of the turtles appears to be in distress and may require transportation |
| to Clearwater Marine Science Center of Florida Fish and Wildlife |
| Conservation Refuge. These are the 69th and 70th live sea turtle rescues at |
| the Crystal River Energy Complex in this biennial period. This is Reportable |
| as a 4-Hour Report under 10 CFR 50.72(b) (2) (xi) as this event is related |
| to the protection of the environment for which a notification to other |
| government agencies (National Marine Fisheries Service and Florida Fish and |
| Wildlife Conservation Commission) has been or will be made. This is an |
| update to event 38602." |
| |
| The NRC Resident Inspector will be notified. The R2DO (Carolyn Evans) was |
| notified. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 38819 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: POINT BEACH REGION: 3 |NOTIFICATION DATE: 04/01/2002|
| UNIT: [1] [2] [] STATE: WI |NOTIFICATION TIME: 13:05[EST]|
| RXTYPE: [1] W-2-LP,[2] W-2-LP |EVENT DATE: 04/01/2002|
+------------------------------------------------+EVENT TIME: 09:17[CST]|
| NRC NOTIFIED BY: THOMAS JESSESSKY |LAST UPDATE DATE: 04/01/2002|
| HQ OPS OFFICER: JOHN MacKINNON +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |DAVID HILLS R3 |
|10 CFR SECTION: | |
|AUNA 50.72(b)(3)(ii)(B) UNANALYZED CONDITION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
|2 N Y 100 Power Operation |100 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| NITROGEN BACKUP SYSTEM FOR CHARGING PUMP SPEED CONTROL FOUND NOT TO
SATISFY |
| APPENDIX R FIRE ASSUMPTION. |
| |
| At 0917 CT on 04/01/02, it was determined that a condition identified on |
| 03/28/02 potentially represents a significant degradation of plant safety |
| during response to an Appendix R event. The Appendix R credited nitrogen |
| backup system for charging pump speed control is unable to satisfy its |
| design function of controlling Charging System flow to the Reactor Coolant |
| System (RCS) for the time required to place the plant in Mode 5 (Cold |
| Shutdown). During an Appendix R fire it is assumed that the normal motive |
| force (instrument air) for charging control is unavailable and an installed |
| backup is credited. This installed nitrogen system allows inventory control |
| while in Mode 3 (Hot Standby) and is used to control RCS inventory and |
| pressure while the RCS is cooled down and depressurized from Mode 3 (Hot |
| Standby) to Mode 5 (Cold Shutdown). A nitrogen bottle 12-pack is calculated |
| to last for approximately 8 hours. PBNP has 1 spare approved nitrogen pack |
| on site - - it has been calculated that up to 15 spares would be required |
| for 72 hours of charging pump operation. Mode 5 (Cold Shutdown) is expected |
| to be reached in 30 hours but may be as long as 72 hours. |
| |
| This issue places the plant in an unanalyzed condition that has the |
| potential to significantly degrade plant safety (RCS Inventory Control) and |
| thus is reportable. |
| |
| The associated charging pumps have been declared out of service for Appendix |
| R use and compensatory actions undertaken that establish appropriate fire |
| rounds. Fire rounds will be continued until the condition is corrected or a |
| suitable evaluation is completed. |
| |
| The NRC Resident Inspector was notified of this event by the licensee. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 38820 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: MONTICELLO REGION: 3 |NOTIFICATION DATE: 04/01/2002|
| UNIT: [1] [] [] STATE: MN |NOTIFICATION TIME: 18:46[EST]|
| RXTYPE: [1] GE-3 |EVENT DATE: 04/01/2002|
+------------------------------------------------+EVENT TIME: 14:36[CST]|
| NRC NOTIFIED BY: DUANE BISTODEAU |LAST UPDATE DATE: 04/01/2002|
| HQ OPS OFFICER: JOHN MacKINNON +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |DAVID HILLS R3 |
|10 CFR SECTION: | |
|AIND 50.72(b)(3)(v)(D) ACCIDENT MITIGATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| DURING SURVEILLANCE TEST "A" DIVISION OF CONTROL ROOM VENTILATION
SYSTEM |
| FAILED TO AUTOSTART ON A LOW FLOW SIGNAL. |
| |
| |
| At 1436 CT on 04/01/02, during a low flow start surveillance test the "A" |
| division of the Control Room Ventilation System failed to autostart. At the |
| time, the "B" division was disabled in order to perform the test. Thus, the |
| Control Room Ventilation System accident mitigation function was lost. |
| Division "B" Control Room Ventilation was restored to operability at 1600 |
| hours CT. The "A" division is operating with the control switch in the run |
| mode. The cause of the failure to Autostart is under investigation. |
| |
| The NRC Resident Inspection will be notified of this event by the licensee. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 38821 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: OCONEE REGION: 2 |NOTIFICATION DATE: 04/01/2002|
| UNIT: [1] [] [] STATE: SC |NOTIFICATION TIME: 21:23[EST]|
| RXTYPE: [1] B&W-L-LP,[2] B&W-L-LP,[3] B&W-L-L|EVENT DATE: 04/01/2002|
+------------------------------------------------+EVENT TIME: 18:00[EST]|
| NRC NOTIFIED BY: STEVE GODFREY |LAST UPDATE DATE: 04/01/2002|
| HQ OPS OFFICER: JOHN MacKINNON +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |CAROLYN EVANS R2 |
|10 CFR SECTION: |JOHN HANNON NRR |
|AUNA 50.72(b)(3)(ii)(B) UNANALYZED CONDITION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N N 0 Refueling |0 Refueling |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| CONTROL ROD DRIVE MECHANISM NOZZLE NO. 7 PENETRATION FOUND TO HAVE A
SMALL |
| LEAK PATH. |
| |
| Qualified visual inspection of the Unit 1 reactor vessel head Control Rod |
| Drive Mechanism head penetrations found two penetrations with very slight |
| boron accumulations. Ultrasonic testing of these penetrations has |
| determined that one nozzle (No. 7, near the center of the reactor vessel |
| head) has a potential reactor coolant system leak path. Any reactor coolant |
| system leakage from penetration No. 7 would have been so small it would be |
| below the threshold of measurability by the reactor coolant system leakage |
| measurement processes. The leaking nozzle will be repaired prior to restart |
| from the present refueling outage. |
| |
| The NRC Resident Inspector will be notified by the licensee of this event. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 38822 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: NINE MILE POINT REGION: 1 |NOTIFICATION DATE: 04/02/2002|
| UNIT: [] [2] [] STATE: NY |NOTIFICATION TIME: 00:49[EST]|
| RXTYPE: [1] GE-2,[2] GE-5 |EVENT DATE: 04/02/2002|
+------------------------------------------------+EVENT TIME: 00:29[EST]|
| NRC NOTIFIED BY: ROGER LONGLEY |LAST UPDATE DATE: 04/02/2002|
| HQ OPS OFFICER: GERRY WAIG +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: UNUSUAL EVENT |GLENN MEYER R1 |
|10 CFR SECTION: |JOHN HANNON NRR |
|AAEC 50.72(a) (1) (i) EMERGENCY DECLARED |NADER MAMISH IRO |
| |KEN SWEETSER FEMA |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
| | |
|2 N N 0 Refueling |0 Refueling |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| UNUSUAL EVENT DECLARED DUE TO FIRE SUPPRESSION SYSTEM CO2 DISCHARGE
IN |
| TURBINE BUILDING |
| |
| The licensee declared an unusual event at 0029 EST due to a broken hose reel |
| on the turbine building fire suppression CO2 system during work activities. |
| The turbine building, reactor building, radioactive waste building, and |
| control building were evacuated. The control room was not evacuated. The |
| broken hose reel was isolated to terminate the release of CO2. No personnel |
| injuries were identified as a result of the event. |
| |
| The NRC Resident Inspector will be notified by the licensee. |
| |
| * * * UPDATE ON 4/2/02 AT 0123 BY ROGER LONGLEY TO GERRY WAIG * * * |
| |
| The licensee terminated the unusual event at 0120 EST. |
| |
| Notified R1DO (Glenn Meyer), NRR EO (Hannon) and FEMA (Ken Sweetser) |
+------------------------------------------------------------------------------+