Skip to main content

The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.

Event Notification Report for March 29, 2002

                         
                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           03/28/2002 - 03/29/2002

                              ** EVENT NUMBERS **

38809  38810  38811  38812  38813  38814  38815  38816  

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38809       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: DRESDEN                  REGION:  3  |NOTIFICATION DATE: 03/28/2002|
|    UNIT:  [] [2] [3]                STATE:  IL |NOTIFICATION TIME: 01:24[EST]|
|   RXTYPE: [1] GE-1,[2] GE-3,[3] GE-3           |EVENT DATE:        03/27/2002|
+------------------------------------------------+EVENT TIME:        22:30[CST]|
| NRC NOTIFIED BY:  BROCK                        |LAST UPDATE DATE:  03/28/2002|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |BRUCE BURGESS        R3      |
|10 CFR SECTION:                                 |                             |
|AUNA 50.72(b)(3)(ii)(B)  UNANALYZED CONDITION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     N          Y       95       Power Operation  |95       Power Operation  |
|3     N          Y       100      Power Operation  |100      Power Operation  |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| SPURIOUS OPERATION OF THE REACTOR HEAD VENT VALVES IN THE SAFE
SHUTDOWN      |
| REPORT(SSR) IS NOT CONSISTENT WITH THE NRC SAFETY EVALUATION REPORT.       
 |
|                                                                              |
|                                                                              |
| Specifically the Section 3.4.3 of the SER states that spurious operation of  |
| the Reactor Head Vent (RHV) valves {SO-2(3)-0220-46 ann SO-2(3)-0220-47}     |
| which would result in Reactor Coolant inventory loss, will be prevented by a |
| pre-fire action to ensure closure by removing power from these valves.       |
| However, the current SSR dispositions this postulated concern based upon the |
| assumption that spurious operation of greater than one normally closed valve |
| in a series combination is not considered a credible failure mode except for |
| high/low pressure systems.   As a result, there is no pre-fire action to     |
| ensure closure by removing power to RHV valves.  The documentation (FPR      |
| revision and 50.59) that supports the change in the licensing position of    |
| these valves from that described in the SER to the current SSR has not been  |
| located.                                                                     |
|                                                                              |
| A review was performed on the Fire Protection Report (FPR) which includes    |
| the Fire Hazard Analysis & Safe Shutdown Analysis, to evaluate the options   |
| for additional sources of water to address the loss of reactor inventory     |
| from the spurious actions of the reactor head vent valves.  This review      |
| indicated that no specific circuit analysis was performed to determine what  |
| other available sources of water could be used for makeup of reactor         |
| inventory via the reactor head vent valves spurious operation.  Therefore,   |
| in the event of a fire in the various assumed Appendix R fire zones, a       |
| qualified makeup source would not be available to mitigate the inventory     |
| loss introduced by the spurious operation of both RHV valves.                |
|                                                                              |
| Fuses have been pulled to remove power to and close a RHV valve on both Unit |
| 2 and Unit 3 to comply with the SER. The action puts the plant in the        |
| configuration required if the RHV valves are considered a high-low pressure  |
| boundary. Completion of this action restores the plants compliance with the  |
| referenced SER.                                                              |
|                                                                              |
| Dresden Engineering will perform an evaluation that documents the RHV valves |
| as a high-low pressure boundary and that the actions taken above are         |
| adequate to mitigate the multiple spurious failures which must be postulated |
| when these valves are considered a high/low pressure boundary.   A revision  |
| to the FPR will be made to document the results of this evaluation.          |
|                                                                              |
| The NRC Resident Inspector will be notified.                                 |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38810       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: HATCH                    REGION:  2  |NOTIFICATION DATE: 03/28/2002|
|    UNIT:  [] [2] []                 STATE:  GA |NOTIFICATION TIME: 09:54[EST]|
|   RXTYPE: [1] GE-4,[2] GE-4                    |EVENT DATE:        03/28/2002|
+------------------------------------------------+EVENT TIME:        03:00[EST]|
| NRC NOTIFIED BY:  ED BURKETT                   |LAST UPDATE DATE:  03/28/2002|
|  HQ OPS OFFICER:  MIKE NORRIS                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |CAROLYN EVANS        R2      |
|10 CFR SECTION:                                 |                             |
|AIND 50.72(b)(3)(v)(D)   ACCIDENT MITIGATION    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| SINGLE TRAIN HPCI DECLARED OOS                                               |
|                                                                              |
| "During valve surveillance testing, Motor Operated Valve 2E41F104 failed to  |
| indicate OPEN.  This is one of two in-line Primary Containment Isolation     |
| Valves (PCIV) that provide vacuum breaker isolation capability for the High  |
| Pressure Coolant Injection (HPCI) Steam Turbine Exhaust line. This failure   |
| resulted in the PCIV being declared INOPERABLE at 0300 on 03-28-2002. To     |
| comply with TS 3.6.1.3.B.1, the companion PCIV, 2E41F111, was CLOSED and     |
| deactivated. This resulted in the HPCI system being declared INOPERABLE,     |
| requiring a notification per 10CFR 50.72 for failure of a single train       |
| system. The HPCI system was scheduled to be removed from service for         |
| pre-planned maintenance, however, the failure of the 2E41F104 was not part   |
| of the pre-planned maintenance activities. The HPCI system has been removed  |
| from service, as scheduled, for performance of the pre-planned maintenance   |
| work.                                                                        |
|                                                                              |
| "As of 0904, the 2E41F104 has been repaired, the equipment clearance         |
| restored, and the valve has been satisfactorily functionally tested.         |
| Complete functional testing and return to service of the HPCI system is in   |
| progress, but has not been completed at this time. It is expected that the   |
| HPCI system will be returned to service today (03-28-2002)."                 |
|                                                                              |
| The NRC Resident has been notified.                                          |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   38811       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  LOUISIANA RADIATION PROTECTION DIV   |NOTIFICATION DATE: 03/28/2002|
|LICENSEE:  TERREBONNE GENERAL MEDICAL CENTER    |NOTIFICATION TIME:
11:08[EST]|
|    CITY:  HOUMA                    REGION:  4  |EVENT DATE:        03/27/2002|
|  COUNTY:                            STATE:  LA |EVENT TIME:             [CST]|
|LICENSE#:  LA-2762-L01           AGREEMENT:  Y  |LAST UPDATE DATE:  03/28/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |CHUCK CAIN           R4      |
|                                                |JOHN HICKEY          NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  SCOOT BLACKWELL              |                             |
|  HQ OPS OFFICER:  MIKE NORRIS                  |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| MEDICAL MISADMINISTRATION                                                    |
| On March 21, 2002, the physician ordered a Resting Myoview scan on a         |
| patient. This patient was assigned a different room and the Nuclear Medicine |
| department was not notified. When the technologist went to inject the        |
| patient he verbally identified the patient and injected the wrong patient    |
| with 20.6 mCi of Tc-99m Myoview. The technologist has suppose to identify    |
| the patient by the ID bracelet but did not. The technologist was been        |
| retrained in the procedure. This misadministration was discovered when the   |
| correct patient was called in for the scan and the patient had not been      |
| injected. The patient that received the misadministration was notified.      |
| There was no apparent harm or injury to the patient. The patient that        |
| received the misadministration was not suppose to be injected with           |
| radiopharmaceuticals at all. The physician received enough information from  |
| the stress test on the correct patient so that patient did not need to be    |
| injected again.                                                              |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   38812       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  CALIFORNIA RADIATION CONTROL PRGM    |NOTIFICATION DATE:
03/28/2002|
|LICENSEE:  CALIFORNIA RADIAITION CONTROL        |NOTIFICATION TIME: 12:52[EST]|
|    CITY:  LONG BEACH               REGION:  4  |EVENT DATE:        03/28/2002|
|  COUNTY:                            STATE:  CA |EVENT TIME:             [PST]|
|LICENSE#:  CA4165                AGREEMENT:  Y  |LAST UPDATE DATE:  03/28/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |CHUCK CAIN           R4      |
|                                                |JOHN HICKEY          NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  ROBERT GREGER                |                             |
|  HQ OPS OFFICER:  RICH LAURA                   |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT FOR STOLEN MOISTURE DENSITY GAGE                      |
|                                                                              |
| "Just received word of a moisture density gauge that was stolen overnight.   |
| Licensee is #4165-37 North County Compaction Engineering Inc., from          |
| Escondido, CA. [ ]. The device is a CPN, model MC-1, S/N M14065450 stolen    |
| from the cab of the operator's truck which he did take to his residence in   |
| Long Beach, CA. Police report filed. The                                     |
| gauge contains nominally 10 mCi of Cs-137 and 30 mCi of Am-241.  The         |
| licensee will place an announcement in the local paper describing [the]      |
| device and offering a reward for the return of the gauge."                   |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   38813       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  ILLINOIS DEPT OF NUCLEAR SAFETY      |NOTIFICATION DATE: 03/28/2002|
|LICENSEE:  SHOLLE CORPORATION                   |NOTIFICATION TIME: 13:39[EST]|
|    CITY:  NORTHLAKE                REGION:  3  |EVENT DATE:        03/27/2002|
|  COUNTY:                            STATE:  IL |EVENT TIME:             [CST]|
|LICENSE#:  9201385               AGREEMENT:  Y  |LAST UPDATE DATE:  03/28/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |BRUCE BURGESS        R3      |
|                                                |JOHN HICKEY          NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  JOE KLINGER                  |                             |
|  HQ OPS OFFICER:  MIKE NORRIS                  |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT FOR A LOST GAUGE                                      |
|                                                                              |
| "A general licensee reported the loss of an NDC Infrared Engineering Model   |
| 103, serial no. 773, containing 100 mCi of Am-241. The gauging device was    |
| initially installed in 1982. The general licensee is a manufacturer of       |
| packaging products. The device was apparently installed at one time in a     |
| plastic extruder line. In November 2000 it was reported to the Department as |
| being on the laminator in the plant. While performing the inventory for the  |
| most recent Departmental self-inspection, the licensee was unable to account |
| for this device. Licensee states that it conducted an extensive              |
| investigation of the circumstances surrounding the disappearance of the      |
| device. Their investigation continues and they will file the required report |
| as soon as possible. The department's investigation is ongoing."             |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   38814       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  ILLINOIS DEPT OF NUCLEAR SAFETY      |NOTIFICATION DATE: 03/28/2002|
|LICENSEE:  NASCOTE INDUSTRIES, INC              |NOTIFICATION TIME: 13:39[EST]|
|    CITY:  NASHVILLE                REGION:  3  |EVENT DATE:        03/27/2002|
|  COUNTY:                            STATE:  IL |EVENT TIME:             [CST]|
|LICENSE#:  GENERAL               AGREEMENT:  Y  |LAST UPDATE DATE:  03/28/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |BRUCE BURGESS        R3      |
|                                                |JOHN HICKEY          NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  JOE KLINGER                  |                             |
|  HQ OPS OFFICER:  MIKE NORRIS                  |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT FOR LOSS OF STATIC ELIMINATOR                         |
|                                                                              |
| "General licensee reported the loss of a Po-210 static eliminator device.    |
| The Licensee presumes that the device was recently lost during routine       |
| manufacturing operations.  The device is manufactured by NRD and is Model    |
| P-2021, Serial no. A2BA986 containing approximately 2 mCi of Po-210.  The    |
| Licensee will continue to search and file the required written report."      |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38815       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: RIVER BEND               REGION:  4  |NOTIFICATION DATE: 03/28/2002|
|    UNIT:  [1] [] []                 STATE:  LA |NOTIFICATION TIME: 20:30[EST]|
|   RXTYPE: [1] GE-6                             |EVENT DATE:        03/28/2002|
+------------------------------------------------+EVENT TIME:        16:43[CST]|
| NRC NOTIFIED BY:  KISHOR L. CHAPANERI          |LAST UPDATE DATE:  03/28/2002|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |CHUCK CAIN           R4      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATIONS  DUE TO UNPLANNED EMERGENCY SIREN ACTUATION           
|
|                                                                              |
| "At  1643, it was discovered that a single River Bend Station Emergency      |
| Siren located in East Baton Rouge Parish had intermittently sounded. A       |
| notification was made to the Louisiana Office of Emergency Preparedness and  |
| a subsequent message is to be broadcast on local radio stations informing    |
| the public that this is an equipment related issue with this siren and no    |
| emergency exists."                                                           |
|                                                                              |
| The licensee informed state/local agencies and the NRC resident inspector.   |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   38816       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  NC DIV OF RADIATION PROTECTION       |NOTIFICATION DATE: 03/28/2002|
|LICENSEE:  THOMPSON-ARTHUR DIVISION APAC-CAROLIN|NOTIFICATION TIME:
23:00[EST]|
|    CITY:  GREENSBORO               REGION:  2  |EVENT DATE:        03/28/2002|
|  COUNTY:                            STATE:  NC |EVENT TIME:             [EST]|
|LICENSE#:  041-039               AGREEMENT:  Y  |LAST UPDATE DATE:  03/28/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |CAROLYN EVANS        R2      |
|                                                |PATRICIA HOLAHAN     NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  LEE COX                      |                             |
|  HQ OPS OFFICER:  STEVE SANDIN                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT INVOLVING A STOLEN TROXLER MOISTURE DENSITY
GAUGE     |
|                                                                              |
| The following is the text from a NC Department of Environment and Natural    |
| Resources News Release:                                                      |
|                                                                              |
| "A truck stolen about 4:30 this afternoon in Forsyth County was transporting |
| an instrument containing eight millicuries of Cesium-137, a radioactive      |
| material that is a potential health and safety risk if handled improperly or |
| broken open.                                                                 |
|                                                                              |
| "The truck is a white Ford F150. The instrument is a Troxler brand portable  |
| moisture density gauge model 4640B.  It is yellow and has a stainless steel  |
| handle with a radiation symbol protruding from a heavy base.  It is about    |
| 20-30 pounds and 24x12x14 inches. Its serial number is 1996. The gauge was   |
| in a yellow box 24x12 inches and marked as containing radioactive material.  |
| The box should be locked and chained to the truck.                           |
|                                                                              |
| "The gauge uses radioactive materials to test conditions of soil and asphalt |
| during construction.  Any health risk would occur only if a person were      |
| directly exposed to the sealed radioactive source inside the instrument.     |
|                                                                              |
| "Employees of Thompson-Arthur Division APAC-Carolina, Inc., a paving company |
| in Greensboro, left the truck unattended. The company's license with the     |
| state Division of Radiation Protection requires that the instrument not be   |
| left unsecured.                                                              |
|                                                                              |
| "Anyone who believes he or she has found the truck, box or gauge should stay |
| at least ten feet away and contact the local sheriffs office, police         |
| department or state highway patrol immediately."                             |
|                                                                              |
| NC Incident No. 02-12.                                                       |
+------------------------------------------------------------------------------+


Page Last Reviewed/Updated Wednesday, March 24, 2021

Page Last Reviewed/Updated Wednesday, March 24, 2021