Event Notification Report for March 27, 2002
U.S. Nuclear Regulatory Commission Operations Center Event Reports For 03/26/2002 - 03/27/2002 ** EVENT NUMBERS ** 38800 38801 38802 38803 +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 38800 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: GINNA REGION: 1 |NOTIFICATION DATE: 03/26/2002| | UNIT: [1] [] [] STATE: NY |NOTIFICATION TIME: 17:22[EST]| | RXTYPE: [1] W-2-LP |EVENT DATE: 03/26/2002| +------------------------------------------------+EVENT TIME: 11:45[EST]| | NRC NOTIFIED BY: KEVIN McLAUGHLIN |LAST UPDATE DATE: 03/26/2002| | HQ OPS OFFICER: BOB STRANSKY +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: NON EMERGENCY |WILLIAM RULAND R1 | |10 CFR SECTION: | | |AESS 50.72(b)(1)(v) EMERGENCY SIREN INOP | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N N 0 Refueling |0 Refueling | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | EMERGENCY SIRENS INOPERABLE | | | | "At 10:15 on March 25, 2002 a silent test was performed from the Monroe | | County Radio Center at Cobb's Hill. The silent test results showed a failure | | of all 24 sirens. A siren reset report printed out shortly afterwards | | showing all 24 sirens normal. The personnel performing the test were | | unfamiliar with the two different types of reports. They thought that the | | reset report was another silent test report. A RG&E technician was informed | | of the siren failure. He contacted Cobb's Hill and determined that the | | system was operating adequately. | | | | "At 11:43 on March 26, 2002, the siren system engineer went to the Monroe | | County 911 Center and performed a silent test. All 24 sirens passed the | | silent test. The test was repeated from West Ave and Cobb's Hill with 100% | | success at these locations. No documentation could be found of any silent | | tests performed on 3/25/02 after the initial failure from Cobb's Hill." | | | | The NRC resident inspector has been informed of this notification by the | | licensee. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Other Nuclear Material |Event Number: 38801 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: PACIFIC RADIOPHARMACY |NOTIFICATION DATE: 03/26/2002| |LICENSEE: PACIFIC RADIOPHARMACY |NOTIFICATION TIME: 17:34[EST]| | CITY: HONALULU REGION: 4 |EVENT DATE: 03/06/2002| | COUNTY: STATE: HI |EVENT TIME: 08:00[HST]| |LICENSE#: 53-16991-01MD AGREEMENT: N |LAST UPDATE DATE: 03/26/2002| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |CHUCK CAIN R4 | | |PATRICIA HOLAHAN NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: TRENT T. PHAN | | | HQ OPS OFFICER: BOB STRANSKY | | +------------------------------------------------+ | |EMERGENCY CLASS: NON EMERGENCY | | |10 CFR SECTION: | | |BAD1 20.2202(a)(1) PERS OVEREXPOSURE/TEDE | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | EXTREMITY OVEREXPOSURE | | | | "[An individual] was observed by inspector Randy Erickson, Health Physicist | | with Region IV, dispensing radiopharmaceuticals that have caused an | | extremity exposure in excess of the limits allowed in 10 CFR | | 20.1201(a)(2)(ii). | | | | "[The individual's] left hand index fingertip exposure is estimated at 700 | | R/yr. The assumptions for the dose estimate is based on the following | | calculation with the left hand index finger supporting a vial containing 100 | | mCi of Tc-99m so it does not fall out of its lead shielding. Page 94 of the | | article 'Fingertip and Whole Body Exposure to Nuclear Medicine Personnel' | | references fingertip exposure of 56 R/year based on 100 mCi vial of Tc-99m, | | 1000 draws/year at 6 seconds per draw. This scenario nearly matches the | | procedure followed by [the individual]. | | | | "40 draws/day x 6 seconds/draw x 6 days/week x 50 weeks/year = 20 | | hours/year | | | | "Based on the article, 1.6 hrs/year exposure to the finger = 56 R. | | Therefore, 56 R/1.6 hrs x 20 hrs = 700 R. | | | | "An NRC form 5 has been completed for [the individual] for calendar year | | 2001. His total effective dose equivalent and total organ dose equivalent, | | maximum organ does not exceed the limits in 10 CFR 20.1201(a)(1) and | | (2)(i)." | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 38802 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: OYSTER CREEK REGION: 1 |NOTIFICATION DATE: 03/26/2002| | UNIT: [1] [] [] STATE: NJ |NOTIFICATION TIME: 18:20[EST]| | RXTYPE: [1] GE-2 |EVENT DATE: 03/26/2002| +------------------------------------------------+EVENT TIME: 16:00[EST]| | NRC NOTIFIED BY: DAVE PETROSKI |LAST UPDATE DATE: 03/26/2002| | HQ OPS OFFICER: BOB STRANSKY +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: NON EMERGENCY |WILLIAM RULAND R1 | |10 CFR SECTION: | | |APRE 50.72(b)(2)(xi) OFFSITE NOTIFICATION | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 100 Power Operation |100 Power Operation | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | OFFSITE NOTIFICATION DUE TO INOPERABLE EFFLUENT RADIATION MONITOR | | | | The licensee notified the Ocean County Utilities Authority, the Ocean County | | Radiological Officer and the Lacey Municipal Utilities Authority that a | | sewage radiation monitor has been inoperable for greater than 24 hours. The | | NRC resident inspector will be informed of this notification by the | | licensee. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 38803 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: BROWNS FERRY REGION: 2 |NOTIFICATION DATE: 03/26/2002| | UNIT: [] [] [3] STATE: AL |NOTIFICATION TIME: 22:01[EST]| | RXTYPE: [1] GE-4,[2] GE-4,[3] GE-4 |EVENT DATE: 03/26/2002| +------------------------------------------------+EVENT TIME: 17:52[CST]| | NRC NOTIFIED BY: R. NACOSTE |LAST UPDATE DATE: 03/26/2002| | HQ OPS OFFICER: BOB STRANSKY +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: NON EMERGENCY |CAROLYN EVANS R2 | |10 CFR SECTION: | | |APRE 50.72(b)(2)(xi) OFFSITE NOTIFICATION | | |AESF 50.72(b)(3)(iv)(A) VALID SPECIF SYS ACTUAT| | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | | | | | | |3 N Y 87 Power Operation |87 Power Operation | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | PRESS RELEASE REGARDING INJURED ELECTRICAL MAINTENANCE WORKERS | | | | The licensee reported that four maintenance workers were injured while | | working on the "3B" 4160 VAC board. The individuals, who were not | | contaminated, were transported offsite for medical treatment. As a result of | | the event, the board deenergized and the "3C" and "3D" emergency diesel | | generators automatically started and loaded to supply power to their | | associated shutdown boards. | | | | The licensee plans to make a press release regarding this event. The NRC | | resident inspector has been informed of this event by the licensee. | +------------------------------------------------------------------------------+
Page Last Reviewed/Updated Wednesday, March 24, 2021
Page Last Reviewed/Updated Wednesday, March 24, 2021