Event Notification Report for March 14, 2002
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
03/13/2002 - 03/14/2002
** EVENT NUMBERS **
38763 38764 38765
+------------------------------------------------------------------------------+
|Other Nuclear Material |Event Number: 38763 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: WHEELING PITTSBURG STEEL CORP. |NOTIFICATION DATE: 03/13/2002|
|LICENSEE: WHEELING PITTSBURG STEEL CORP |NOTIFICATION TIME: 13:43[EST]|
| CITY: FOLLANSBEE REGION: 2 |EVENT DATE: 03/12/2002|
| COUNTY: BROOKE STATE: WV |EVENT TIME: [EST]|
|LICENSE#: 47-16875-01 AGREEMENT: N |LAST UPDATE DATE: 03/13/2002|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |MARK LESSER R2 |
| |JOHN HICKEY NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: BARBARA BOOKER | |
| HQ OPS OFFICER: GERRY WAIG | |
+------------------------------------------------+ |
|EMERGENCY CLASS: NON EMERGENCY | |
|10 CFR SECTION: | |
|IBBE 30.50(b)(2) SAFETY EQUIPMENT FAILUR| |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| SOURCE SHIELD SHUTTER WOULD NOT CLOSE |
| |
| A Cs-137, 2 curie source (1978), shield shutter would not close to secure |
| source in the shield on the coke line. Licensee took compensatory measures |
| to secure source by manually closing and blocking the shutter in the closed |
| position. Additionally, a cable and counter-weight have been utilized to |
| maintain the shutter in the secure condition. No personnel exposures were |
| received as a result of this event. The licensee plans to remove the |
| defective unit on 3/15/02 and ship it to a vendor (Texas Nuclear) for |
| repair. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Other Nuclear Material |Event Number: 38764 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: YALE UNIVERSITY |NOTIFICATION DATE: 03/13/2002|
|LICENSEE: YALE UNIVERSITY |NOTIFICATION TIME: 16:37[EST]|
| CITY: NEW HAVEN REGION: 1 |EVENT DATE: 03/13/2002|
| COUNTY: NEW HAVEN STATE: CT |EVENT TIME: 15:00[EST]|
|LICENSE#: 0600183-03 AGREEMENT: N |LAST UPDATE DATE: 03/13/2002|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |DAVID LEW R1 |
| |THOMAS ESSIG NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: TAMMY STEMEN | |
| HQ OPS OFFICER: GERRY WAIG | |
+------------------------------------------------+ |
|EMERGENCY CLASS: NON EMERGENCY | |
|10 CFR SECTION: | |
|BAB1 20.2201(a)(1)(i) LOST/STOLEN LNM>1000X | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| TWO TRITIUM EXIT SIGNS MISSING FROM MOUNTING BRACKETS |
| |
| During a review and inventory of tritium exit signs to be replaced with |
| non-tritium signs, two exit sign brackets, without signs, were identified. |
| Both missing signs were from the Arts and Architecture building and were |
| 11.5 curies each. The signs were manufactured by Isolite, model #880. The |
| licensee intends to contact the contractor who originally installed the |
| signs, students, faculty, and the building supervisor for information to |
| locate the missing signs. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 38765 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PERRY REGION: 3 |NOTIFICATION DATE: 03/13/2002|
| UNIT: [1] [] [] STATE: OH |NOTIFICATION TIME: 20:21[EST]|
| RXTYPE: [1] GE-6 |EVENT DATE: 03/13/2002|
+------------------------------------------------+EVENT TIME: 18:30[EST]|
| NRC NOTIFIED BY: MICHAEL NEMCEK |LAST UPDATE DATE: 03/13/2002|
| HQ OPS OFFICER: GERRY WAIG +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |MONTE PHILLIPS R3 |
|10 CFR SECTION: | |
|AIND 50.72(b)(3)(v)(D) ACCIDENT MITIGATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| HIGH PRESSURE CORE SPRAY SYSTEM INOPERABLE |
| |
| "During the performance of a surveillance (E22-T2004) for high pressure core |
| spray system (HPCS), the condensate storage tank suction check valve |
| (1E22F0002) failed to seat properly. The operability determination for the |
| check valve determined that there was significant potential that the check |
| valve springs had broken resulting in foreign material in the HPCS system. |
| Since the long-term operation of the system was potentially impacted, the |
| system was declared inoperable at 1830. HPCS is a single train safety |
| system." The licensee verified the operability of RCIC within one hour. |
| |
| The licensee notified the NRC Resident. |
+------------------------------------------------------------------------------+