The U.S. Nuclear Regulatory Commission is in the process of rescinding or revising guidance and policies posted on this webpage in accordance with Executive Order 14151 Ending Radical and Wasteful Government DEI Programs and Preferencing, and Executive Order 14168 Defending Women From Gender Ideology Extremism and Restoring Biological Truth to the Federal Government. In the interim, any previously issued diversity, equity, inclusion, or gender-related guidance on this webpage should be considered rescinded that is inconsistent with these Executive Orders.

Event Notification Report for March 4, 2002

                         
                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           03/01/2002 - 03/04/2002

                              ** EVENT NUMBERS **

38518  38602  38611  38634  38741  38742  38743  38744  38745  38746  38747  

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38518       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: POINT BEACH              REGION:  3  |NOTIFICATION DATE: 11/26/2001|
|    UNIT:  [1] [2] []                STATE:  WI |NOTIFICATION TIME: 13:37[EST]|
|   RXTYPE: [1] W-2-LP,[2] W-2-LP                |EVENT DATE:        11/26/2001|
+------------------------------------------------+EVENT TIME:        12:32[CST]|
| NRC NOTIFIED BY:  ROBERT ADAMS                 |LAST UPDATE DATE:  03/01/2002|
|  HQ OPS OFFICER:  JOHN MacKINNON               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |BRUCE JORGENSEN      R3      |
|10 CFR SECTION:                                 |                             |
|NONR                     OTHER UNSPEC REQMNT    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| ERDS INOPERABLE DUE TO PLANNED OUTAGE OF THE PLANT PROCESS COMPUTER
SYSTEM   |
| (PPCS)                                                                       |
|                                                                              |
| AT 1232 CT, the Point Beach Nuclear Plant ERDS became inoperable as a result |
| of modifications to change out the plant process computer system (PPCS).     |
| This is a planned evolution.  ERDS will remain inoperable until              |
| approximately, December 18, 2001.                                            |
|                                                                              |
| This information was verbally provided to a representative of NRR during the |
| week of 10/15/2001.  The senior resident inspector has also been briefed on  |
| the modifications and schedule.  NMC to NRC letter (NRC 01-0080) dated       |
| 11/21/2001 stated we would be submitting this Non-Emergency report.          |
|                                                                              |
| ***** UPDATE FROM RICK ROBBINS TO LEIGH TROCINE AT 2006 EST ON 11/27/01      |
| *****                                                                        |
|                                                                              |
| The following additional information is a portion of a facsimile received    |
| from the licensee:                                                           |
|                                                                              |
| "As part of the PPCS modification, several inputs to the SPDS monitor were   |
| also made unavailable.  Any out-of-service indications on the SPDS can be    |
| obtained by control room control board indications."                         |
|                                                                              |
| The licensee notified the NRC resident inspector.  The NRC operations center |
| notified the R3DO (Bruce Jorgensen).                                         |
|                                                                              |
| * * * UPDATE 1259EST ON 12/22/01 FROM RYAN RODE TO S. SANDIN * * *           |
|                                                                              |
| The licensee provided the following information as an update:                |
|                                                                              |
| "On 11/26/01 at 12:32, the PBNP ERDS and SPDS were declared out of service   |
| for the PPCS upgrade project.  EN #38518 indicated to the NRC that the       |
| systems would remain unavailable until approximately December 18, 2001.  Due |
| to reliability issues with the newly installed PPCS, that expected date has  |
| been delayed to approximately January 3, 2002."                              |
|                                                                              |
| The licensee informed the NRC Resident Inspector.  Notified R3DO(Phillips).  |
|                                                                              |
| * * * UPDATE ON 01/03/02 @1430 BY MEYER TO GOULD * * *                       |
|                                                                              |
| During the installation of the new PPCS, issues were identified which need   |
| to be resolved to allow SPDS and ERDS to be placed back in service fully.    |
| Currently, the new PPCS is only partially operable.  Work is continuing on   |
| the new PPCS to allow full operability.  The current estimate for return to  |
| service of SPDS and ERDS is 01/19/02.  This date may need to be extended     |
| again due to parts availability.                                             |
|                                                                              |
| The NRC Resident Inspector was notified.                                     |
|                                                                              |
| Notified Reg 3 RDO(Shear)                                                    |
|                                                                              |
| * * * UPDATE ON 1/17/02 @ 1855 BY HARRSCH TO GOULD * * *                     |
|                                                                              |
| Update to 1/3/02 update (see below).  Work continues on the Plant Process    |
| Computer System (PPCS) to allow full operability. The Safety Parameter       |
| Display System (SPDS) is still out of service, however the Emergency         |
| Response Data System (ERDS) is now available. As mentioned in the 1/3/02     |
| update, parts availability has been a problem and the date for returning     |
| SPDS to service is now estimated to be 2/16/02.                              |
|                                                                              |
| The NRC Resident Inspector was notified.                                     |
|                                                                              |
| Reg 3 RDO(Vegel) was informed                                                |
|                                                                              |
| ***UPDATE ON 2/15/02 @ 1323 EST BY ADAMS TO NORRIS***                        |
|                                                                              |
| Update to 1/17/02 update.  Work continues on the Plant Process Computer      |
| System (PPCS) to allow full operability. The Safety Parameter Display System |
| (SPDS) is still out of service.  Due to parts availabilty, the date for      |
| returning SPDS to service is now estimated to be 3/09/02.                    |
|                                                                              |
| The NRC Resident Inspector was notified.                                     |
|                                                                              |
| Reg 3 RDO(Vegel) was informed.                                               |
|                                                                              |
| ***UPDATE ON 3/1/02 @ 1145 EST BY MILLEN TO NORRIS***                        |
|                                                                              |
| Update to 1/17/02 event notification.  As part of the upgade to the Plant    |
| Process Comuter System (PPCS), the Safety Parameter Display System (SPDS)    |
| has been accepted for use and is considered fully operational.               |
|                                                                              |
| The NRC Resident Inspector was notified.                                     |
|                                                                              |
| Reg 3 RDO (Lipa) was informed.                                               |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38602       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: CRYSTAL RIVER            REGION:  2  |NOTIFICATION DATE: 01/01/2002|
|    UNIT:  [3] [] []                 STATE:  FL |NOTIFICATION TIME: 10:08[EST]|
|   RXTYPE: [3] B&W-L-LP                         |EVENT DATE:        01/01/2002|
+------------------------------------------------+EVENT TIME:        09:19[EST]|
| NRC NOTIFIED BY:  BILL BANDHAUER               |LAST UPDATE DATE:  03/01/2002|
|  HQ OPS OFFICER:  FANGIE JONES                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |ANNE BOLAND          R2      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|3     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION DUE RESCUED SEA TURTLE                                  |
|                                                                              |
| EN #37902 started the biennial report period.                                |
|                                                                              |
| On January 1, 2002 at 0919, a rescued sea turtle was identified as a green   |
| sea turtle.  This is the 62nd rescue of a live sea turtle at Crystal River   |
| Unit 3 (CR-3) in this biennial period. Notification to the National Marine   |
| Fisheries Service and the Florida Fish and Wildlife Conservation Commission. |
|                                                                              |
|                                                                              |
| The licensee intends to notify the NRC Resident Inspector.                   |
|                                                                              |
| * * *  UPDATE ON 1/05/02 @ 1002 BY RAWLS TO GOULD  * * *                     |
|                                                                              |
| On January 5, 2002, at 0720, a rescued sea turtle was identified as a        |
| Loggerhead Sea Turtle. This is the 63rd rescue of a live sea turtle at       |
| Crystal River Unit 3 (CR3) in this biennial period.  This is reportable as a |
| 4-hour report under 10 CFR 50.72(b)(2)(xi) as this event is related to the   |
| protection of the environment for which a notification to other government   |
| agencies (National Marine Fisheries Service and Florida Fish and Wildlife    |
| Conservation Commission) has been or will be made.                           |
|                                                                              |
| The NRC Resident Inspector was notified.                                     |
|                                                                              |
| Reg 2 RDO (Decker) was notified.                                             |
|                                                                              |
| * * * UPDATE ON 01/09/02 @ 1107 EST BY ANDY BARNES TAKEN BY MACKINNON * * *  |
|                                                                              |
| On January 9, 2002, at 0838, a rescued sea turtle was identified as a Kemp's |
| Ridley Sea Turtle. This is the 64th rescue of a live turtle at Crystal River |
| Unit 3 (CR-3) in this biennial period. This is reportable as a 4-hour 10 CFR |
| 50.72 (b)(2)(xi) as this event is related to the protection of the           |
| environment for which a notification to other government agencies (National  |
| Marine Fisheries Service and Florida Fish and Wildlife Conservation          |
| Commission) has been or will be made.                                        |
|                                                                              |
| The NRC Resident Inspector was notified.                                     |
|                                                                              |
| Reg 2 (Brian Bonser) was notified.                                           |
|                                                                              |
| * * * UPDATE ON 02/17/02 at 0940 EST BY RICKY RAWLS TO FANGIE JONES * * *    |
|                                                                              |
| "On February 17, 2002 at 0820, a rescued injured sea turtle was identified   |
| as a Kemp's Ridley Sea Turtle. The injury will require transportation to     |
| Clearwater Marine Science Center or Florida Fish and Wildlife Conservation   |
| Refuge. The Injury appears to be from a boat propeller. This is the 65th     |
| rescue of a live sea turtle at Crystal River Unit 3 (CR-3) in this biennial  |
| period. This is Reportable as a 4-Hour Report under 10 CFR 50.72(b) (2) (xi) |
| as this event is related to the protection of the environment for which a    |
| notification to other government agencies (National Marine Fisheries Service |
| and Florida Fish and Wildlife Conservation Commission) has been or will be   |
| made. This Is an update to event 38602."                                     |
|                                                                              |
| The NRC Resident Inspector will be notified.  R2DO (Stephen Cahill) has been |
| notified.                                                                    |
|                                                                              |
| * * * UPDATE ON 03/01/02 AT 1122 EST BY RICKY RAWLS TO GERRY WAIG * * *      |
|                                                                              |
| "On March 1, 2002 at 0952, a healthy rescued sea turtle was identified as a  |
| Green Sea Turtle. This is the 66th rescue of a live sea turtle at Crystal    |
| River Unit 3 (CR-3) in this biennial period. This is Reportable as a 4-Hour  |
| Report under 10 CFR 50.72 (b) (2) (xi) as this event is related to the       |
| protection of the environment for which a notification to other government   |
| agencies (National Marine Fisheries Service and Florida Fish and Wildlife    |
| Conservation Commission) has been or will be made. This is an update to      |
| event 38602."                                                                |
|                                                                              |
| The NRC Resident Inspector was notified. R2DO (Julian) was notified.         |
+------------------------------------------------------------------------------+

!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED  !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38611       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: HOPE CREEK               REGION:  1  |NOTIFICATION DATE: 01/06/2002|
|    UNIT:  [1] [] []                 STATE:  NJ |NOTIFICATION TIME: 21:42[EST]|
|   RXTYPE: [1] GE-4                             |EVENT DATE:        01/06/2002|
+------------------------------------------------+EVENT TIME:        14:10[EST]|
| NRC NOTIFIED BY:  PARKER                       |LAST UPDATE DATE:  03/01/2002|
|  HQ OPS OFFICER:  JOHN MacKINNON               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |MOHAMED SHANBAKY     R1      |
|10 CFR SECTION:                                 |                             |
|AIND 50.72(b)(3)(v)(D)   ACCIDENT MITIGATION    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| HIGH PRESSURE COOLANT INJECTION (HPCI) SYSTEM DECLARED INOPERABLE           
|
|                                                                              |
| During the performance of the quarterly valve surveillance test for the HPCI |
| system, a testable check valve, 1FD-V032, related to the HPCI Barometric     |
| Condenser Discharge Line, failed.  This failure rendered the HPCI system     |
| inoperable at 1410 EST on 01/06/02. The licensee entered an active 14 day    |
| Limiting Condition of Operation that expires on 01/20/02 at 1410 EST.  All   |
| other safety systems are operable.  Current plans to return plant to normal  |
| configuration include the development of corrective maintenance work         |
| package.                                                                     |
|                                                                              |
| The NRC Resident Inspector will be notified of this event by the licensee.   |
|                                                                              |
| ***3/1/02 0952 Event was retracted by Licensee;  Jim Priest to Mike          |
| Norris.***                                                                   |
|                                                                              |
| "PSEG Nuclear retracts the event notification made on 1/6/02 (event number   |
| 38611).                                                                      |
|                                                                              |
| "Barometric condenser condensate pump discharge check valve 1 FD-V032 was    |
| opened and inspected. The valve internals were cleaned and the valve was     |
| reassembled and retested satisfactorily.                                     |
|                                                                              |
| "Subsequent evaluation determined that failure of 1 FD-V032 to close would   |
| not have prevented the HPCI system from performing its safety function.      |
| Reverse flow through 1 FD-V032 would not degrade the flow that HPCI supplies |
| the reactor vessel during a postulated accident.                             |
|                                                                              |
| "Since the HPCI system remained capable of performing its safety function,   |
| this event is not reportable.                                                |
|                                                                              |
| "The NRC Resident Inspector has been notified of this event by the           |
| licensee."                                                                   |
|                                                                              |
| Notified R1DO (Linville)                                                     |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38634       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SAINT LUCIE              REGION:  2  |NOTIFICATION DATE: 01/17/2002|
|    UNIT:  [1] [2] []                STATE:  FL |NOTIFICATION TIME: 13:07[EST]|
|   RXTYPE: [1] CE,[2] CE                        |EVENT DATE:        01/17/2002|
+------------------------------------------------+EVENT TIME:        11:45[EST]|
| NRC NOTIFIED BY:  KELLY KORTH                  |LAST UPDATE DATE:  03/02/2002|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |ROBERT HAAG          R2      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION  INVOLVING RECOVERED SEA TURTLE FROM INTAKE CANAL    
  |
|                                                                              |
| At approximately 1130 EST on 01/17/02, a green sea turtle was retrieved from |
| the intake canal and a determination was made that it was in need of         |
| rehabilitation.  As required by the Plant's Sea Turtle Permit, the Florida   |
| Fish and Wildlife Conservation Commission (FFWCC) was notified at 1145 EST.  |
|                                                                              |
| The licensee notified the NRC Resident Inspector.                            |
|                                                                              |
| See EN #38513 for 2001 occurrences.                                          |
|                                                                              |
| * * * UPDATE ON 1/28/02  @ 1243 BY KORTH TO GOULD * * *                      |
|                                                                              |
| At approximately 1115 on 1/28/02 a loggerhead turtle was retrieved from the  |
| plant's  intake canal.  The turtle was determined to be in need of           |
| rehabilitation.  Per the licensee's turtle permit, the Florida Fish and      |
| Wildlife Conservation Commission (FWCC) was notified at 1125.                |
|                                                                              |
| The NRC Resident Inspector was notified.   Notified Reg 2 RDO (Ninh)         |
|                                                                              |
|                                                                              |
| * * * UPDATE ON 2/6/02 @ 0853 BY MERRILL TO GOULD * * *                      |
|                                                                              |
| At approximately 0745 on 2/6/02 an injured green sea turtle was rescued from |
| the plant's intake canal.  The turtle was alive, but in need of              |
| rehabilitation.  The turtle will be transported to a facility in Clearwater  |
| for treatment.  The Florida Department of Environmental Protection has been  |
| notified of the event.                                                       |
|                                                                              |
| The NRC Resident Inspector was notified.                                     |
|                                                                              |
| Notified Reg 2 RDO(Fredrickson)                                              |
|                                                                              |
| * * * UPDATE 1025 3/2/2002 BY R. DIEHL TAKEN BY R. STRANSKY * * *            |
|                                                                              |
| "At approximately 0830 3/2/02 a Loggerhead turtle was retrieved from the     |
| plant's intake canal. The turtle was determined to be in need of             |
| rehabilitation. Per the plant's turtle permit, the Florida Fish and Wildlife |
| Conservation Commission (FWCC) was notified at 0845."                        |
|                                                                              |
| The NRC resident inspector has been informed of this report. HOO notified    |
| R2DO (Julian).                                                               |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38741       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: LIMERICK                 REGION:  1  |NOTIFICATION DATE: 03/01/2002|
|    UNIT:  [1] [2] []                STATE:  PA |NOTIFICATION TIME: 02:29[EST]|
|   RXTYPE: [1] GE-4,[2] GE-4                    |EVENT DATE:        03/01/2002|
+------------------------------------------------+EVENT TIME:        02:16[EST]|
| NRC NOTIFIED BY:  PHILIP CHASE                 |LAST UPDATE DATE:  03/01/2002|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |JAMES LINVILLE       R1      |
|10 CFR SECTION:                                 |                             |
|DDDD 73.71               UNSPECIFIED PARAGRAPH  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       87       Power Operation  |87       Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| SECURITY REPORT                                                              |
|                                                                              |
| Unescorted access granted inappropriately to contract employee.  Immediate   |
| compensatory measures taken upon discovery.  The licensee will inform the    |
| NRC resident inspector.  Contact the Headquarters Operations Officer for     |
| additional details.                                                          |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   38742       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  TEXAS DEPARTMENT OF HEALTH           |NOTIFICATION DATE: 03/01/2002|
|LICENSEE:  PROTECHNICS                          |NOTIFICATION TIME: 08:52[EST]|
|    CITY:  HOUSTON                  REGION:  4  |EVENT DATE:        02/14/2002|
|  COUNTY:  HARRIS                    STATE:  TX |EVENT TIME:             [CST]|
|LICENSE#:  LO3835                AGREEMENT:  Y  |LAST UPDATE DATE:  03/01/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |DAVID GRAVES         R4      |
|                                                |FRED BROWN           NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  JAMES H. OGDEN JR.           |                             |
|  HQ OPS OFFICER:  MIKE NORRIS                  |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT INVOLVING A STUCK LOGGING WELL SOURCE                 |
|                                                                              |
| "Well logging tool became stuck at 17,125 feet, top of tool is 17,106 feet.  |
| Attempted fishing on 3 consecutive days,  unsuccessful.  Pumped 466 feet of  |
| red cement to secure source on February 14, 2002, to plug well.  Top of plug |
| is 16,640 feet.  Permanent identification plaque is under construction for   |
| emplacement on the wellhead.  Abandoned at Frank Bell #1 RE, Leon County,    |
| Texas, AP# 42-289-30432.  Source abandoned IAW Texas Regulations.            |
|                                                                              |
| "Isotope Products Laboratory, sealed logging source (Capsule Type), Model #  |
| HEG-241, Serial # NN-082, 250 microcuries Am-241.  Last leak tested 09/07/01 |
| (No leakage).  Manufactured September 25, 1998, pressure tested to 25,000    |
| psi."                                                                        |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38743       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: WATTS BAR                REGION:  2  |NOTIFICATION DATE: 03/01/2002|
|    UNIT:  [1] [] []                 STATE:  TN |NOTIFICATION TIME: 10:20[EST]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        03/01/2002|
+------------------------------------------------+EVENT TIME:        02:59[EST]|
| NRC NOTIFIED BY:  R. Kimbrough                 |LAST UPDATE DATE:  03/01/2002|
|  HQ OPS OFFICER:  GERRY WAIG                   +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |CAUDLE JULIAN        R2      |
|10 CFR SECTION:                                 |                             |
|AINB 50.72(b)(3)(v)(B)   POT RHR INOP           |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Refueling        |0        Refueling        |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| UNIT EXPERIENCED MOMENTARY LOSS OF RHR COOLING                               |
|                                                                              |
| "At approximately 0259 on March 1, 2002, with the Watts Bar Unit 1 reactor   |
| in Mode 6 with RCS temperature at approximately 100 degrees, during a        |
| refueling outage, operators isolated the common flowpath to the residual     |
| heat removal (RHR) pumps on two occasions over a 2 minute span. At the time  |
| of the event, operators were performing full flow testing of ECCS lines in   |
| conjunction with reactor cavity fill for refueling activities.               |
|                                                                              |
| The circumstances of the event are currently under investigation by the Site |
| staff."                                                                      |
|                                                                              |
| No observable RCS heatup occurred during the period that RHR was isolated.   |
|                                                                              |
| The NRC resident inspector was notified.                                     |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   38744       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  LOUISIANA RADIATION PROTECTION DIV   |NOTIFICATION DATE: 03/01/2002|
|LICENSEE:  METCO SULPHUR                        |NOTIFICATION TIME: 15:05[EST]|
|    CITY:                           REGION:  4  |EVENT DATE:        02/22/2002|
|  COUNTY:                            STATE:  LA |EVENT TIME:        18:30[CST]|
|LICENSE#:  LA-8043-L01           AGREEMENT:  Y  |LAST UPDATE DATE:  03/01/2002|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |DAVID GRAVES         R4      |
|                                                |FRED BROWN           NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  SCOTT BLACKWELL              |                             |
|  HQ OPS OFFICER:  GERRY WAIG                   |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT - LOCK MALFUNCTION ON CAMERA                          |
|                                                                              |
| "On Friday February 22, 2002, a radiographer from METCO discovered that the  |
| lock on the Amersham 660 radiography camera with 60 curies of Ir-192 would   |
| not release to allow  an exposure. The Environmental Manager from LA Pigment |
| believed the auto-lock on the exposure device failed. The RSO at METCO       |
| responded within 30 minutes. The RSO stated that he cleaned the lock with    |
| WD-40 and the lock functioned after that. The RSO believes the lock was just |
| dirty."                                                                      |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38745       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: HARRIS                   REGION:  2  |NOTIFICATION DATE: 03/01/2002|
|    UNIT:  [1] [] []                 STATE:  NC |NOTIFICATION TIME: 18:14[EST]|
|   RXTYPE: [1] W-3-LP                           |EVENT DATE:        03/01/2002|
+------------------------------------------------+EVENT TIME:             [EST]|
| NRC NOTIFIED BY:  MARK ELLINGTON               |LAST UPDATE DATE:  03/01/2002|
|  HQ OPS OFFICER:  FANGIE JONES                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |CAUDLE JULIAN        R2      |
|10 CFR SECTION:                                 |                             |
|AUNA 50.72(b)(3)(ii)(B)  UNANALYZED CONDITION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| UNANALYZED CONDITION DUE TO FIRE BARRIERS NOT INSTALLED PER DESIGN          
|
|                                                                              |
| "On March 1, 2002, Harris Nuclear Plant personnel determined that an         |
| unanalyzed condition existed due to a required three-hour fire barrier not   |
| installed per design. The applicable fire barrier was designed to provide    |
| required separation between redundant train cables supplying A-SA Emergency  |
| Diesel Generator and B-SB Emergency Diesel Generator. Harris Nuclear Plant   |
| has initiated a continuous fire watch as a compensatory measure until the    |
| affected barrier could be restored to the design configuration. This issue   |
| is being reported in accordance with 10 CFR 50.72 as an unanalyzed           |
| condition."                                                                  |
|                                                                              |
| The licensee notified the NRC Resident Inspector.                            |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38746       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SALEM                    REGION:  1  |NOTIFICATION DATE: 03/03/2002|
|    UNIT:  [1] [] []                 STATE:  NJ |NOTIFICATION TIME: 04:25[EST]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        03/03/2002|
+------------------------------------------------+EVENT TIME:        02:18[EST]|
| NRC NOTIFIED BY:  VAN FORD                     |LAST UPDATE DATE:  03/03/2002|
|  HQ OPS OFFICER:  BOB STRANSKY                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |JAMES LINVILLE       R1      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |45       Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION DUE TO OIL SPILL INTO DELAWARE RIVER                    |
|                                                                              |
| "On March 3, 2002 at 0218 a cooling line to 12B circulating water pump upper |
| motor bearing ruptured inside the upper oil reservoir. Oil was displaced     |
| from the oil reservoir and approximately 50 gallons of oil entered the       |
| Delaware River. 12B circulating water pump was removed from service and the  |
| leak was terminated. Cleanup efforts by onsite personnel are in progress. A  |
| 15 minute report was made to the New Jersey Department of Environmental      |
| Protection. A two hour report was made to the National Response Center in    |
| accordance with the site spill plan.                                         |
|                                                                              |
| Salem Unit 1 was initially at 100% power with 13B circulating water pump out |
| of service for scheduled maintenance. Power reduction is currently in        |
| progress in response to the loss of 12B circulating water pump with a target |
| power level of 40%."                                                         |
|                                                                              |
| The NRC resident inspector has been informed of this notification by the     |
| licensee.                                                                    |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38747       |
+------------------------------------------------------------------------------+
                         
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SUSQUEHANNA              REGION:  1  |NOTIFICATION DATE: 03/03/2002|
|    UNIT:  [1] [] []                 STATE:  PA |NOTIFICATION TIME: 06:04[EST]|
|   RXTYPE: [1] GE-4,[2] GE-4                    |EVENT DATE:        03/03/2002|
+------------------------------------------------+EVENT TIME:        03:00[EST]|
| NRC NOTIFIED BY:  GORDON ROBINSON              |LAST UPDATE DATE:  03/03/2002|
|  HQ OPS OFFICER:  BOB STRANSKY                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |JAMES LINVILLE       R1      |
|10 CFR SECTION:                                 |                             |
|ADEG 50.72(b)(3)(ii)(A)  DEGRADED CONDITION     |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Cold Shutdown    |0        Cold Shutdown    |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| MSIV LEAKAGE EXCEEDS ALLOWABLE LIMIT                                         |
|                                                                              |
| "Leak Rate Testing on Unit 1 Main Steam Isolation Valves has identified that |
| the total minimum pathway leak rate exceeds the required limit of 300 scfh.  |
| The MSIV pathway combined leak rate was 1051 scfh. The identified degraded   |
| condition is reportable as a condition of the nuclear power plant, including |
| its principal safety barriers being seriously degraded per                   |
| 10CFR50.72(b)(3)(ii)."                                                       |
|                                                                              |
| The NRC resident inspector will be informed of this notification by the      |
| licensee.                                                                    |
+------------------------------------------------------------------------------+
