The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.
Event Notification Report for December 14, 2001
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
12/13/2001 - 12/14/2001
** EVENT NUMBERS **
38560 38561
.
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 38560 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: CARBOLINE COMPANY |NOTIFICATION DATE: 12/13/2001|
|LICENSEE: CARBOLINE COMPANY |NOTIFICATION TIME: 16:06[EST]|
| CITY: BRENTWOOD REGION: 3 |EVENT DATE: 12/13/2001|
| COUNTY: STATE: MO |EVENT TIME: 12:00[CST]|
|LICENSE#: AGREEMENT: N |LAST UPDATE DATE: 12/13/2001|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |CLIFFORD ANDERSON R1 |
| |ANNE MARIE STONE R3 |
+------------------------------------------------+ |
| NRC NOTIFIED BY: RICHARD MIDDEKE | |
| HQ OPS OFFICER: JOHN MacKINNON | |
+------------------------------------------------+ |
|EMERGENCY CLASS: | |
|10 CFR SECTION: | |
|CCCC 21.21 UNSPECIFIED PARAGRAPH | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| CARBOZINC 11 SG HAS BEEN DETERMINED TO HAVE A REPORTABLE DEFECT.
|
| |
| Carboline has been notified of stability problems with some Carbozinc 11 SG |
| product over the last year. The material is exhibiting premature gellation |
| or thickening prior to the end of the published shelf life expiration date. |
| Carbozinc 11 SG that is gelled or exhibiting significant thickening will not |
| atomize or spray properly, resulting in poor adhesion to the substrate. |
| When this occurs the coating cracks during the spray process and the coating |
| process and the coating flakes off the substrate. |
| |
| On December 14, 2001, Carboline will send by register mail to all purchasers |
| of Carbozinc 11 SG reporting Part 21 Reporting of Defect. |
| |
| See event number 38408, reported 10/19/2001 for background information. |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 38561 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: TEXAS DEPARTMENT OF HEALTH |NOTIFICATION DATE: 12/13/2001|
|LICENSEE: BAPTIST HEALTH SYSTEM |NOTIFICATION TIME: 17:00[EST]|
| CITY: SAN ANTONIO REGION: 4 |EVENT DATE: 12/09/2001|
| COUNTY: STATE: TX |EVENT TIME: [CST]|
|LICENSE#: L-00455 AGREEMENT: Y |LAST UPDATE DATE: 12/13/2001|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |BILL JONES R4 |
| |C.W. (BILL) REAMER NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: JAMES H. OGDEN | |
| HQ OPS OFFICER: JOHN MacKINNON | |
+------------------------------------------------+ |
|EMERGENCY CLASS: NON EMERGENCY | |
|10 CFR SECTION: | |
|NAGR AGREEMENT STATE | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| LOST RADIOACTIVE SEALED SOURCE |
| |
| Hospital had a package of 94 I-125 seeds at 310 microcuries each delivered |
| on December 9, 2001. Package was delivered to the nuclear medicine |
| department and left on top of boxes that the person delivering thought would |
| be seen by nuclear medicine personnel. The package was not accepted by an |
| individual in nuclear medicine. At the time of the scheduled treatment, |
| December 11, 2001, nuclear medicine called to see where the seeds were and |
| were told that they had arrived on the 9th and had been delivered to nuclear |
| medicine. The seeds were packaged and the seeds cannot be found. |
| |
| Texas Incident No. I-7839. |
+------------------------------------------------------------------------------+
.
Page Last Reviewed/Updated Wednesday, March 24, 2021