The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.
Event Notification Report for November 19, 2001
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
11/16/2001 - 11/19/2001
** EVENT NUMBERS **
37902 38506 38509
.
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37902 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: CRYSTAL RIVER REGION: 2 |NOTIFICATION DATE: 04/09/2001|
| UNIT: [3] [] [] STATE: FL |NOTIFICATION TIME: 11:08[EDT]|
| RXTYPE: [3] B&W-L-LP |EVENT DATE: 04/09/2001|
+------------------------------------------------+EVENT TIME: 09:54[EDT]|
| NRC NOTIFIED BY: RICHARD SWEENEY |LAST UPDATE DATE: 11/17/2001|
| HQ OPS OFFICER: STEVE SANDIN +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |CAUDLE JULIAN R2 |
|10 CFR SECTION: | |
|APRE 50.72(b)(2)(xi) OFFSITE NOTIFICATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|3 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION TO THE NATIONAL MARINE AND FISHERIES SERVICE AS A
|
| RESULT OF THE ENDANGERED SEA TURTLES NON-LETHAL TAKE LIMIT BEING
EXCEEDED |
| |
| "On April 09, 2001 at 0940 the 40th non-lethal sea turtle take in the |
| biennial period occurred. |
| |
| "In accordance with Crystal River Unit #3 Operating License, Appendix B, |
| Environmental Protection Plan (Non-Radiological), 'Endangered or threatened |
| sea turtles shall be protected in accordance with the Incidental Take |
| Statement issued by the National Marine and Fisheries Service (NMFS).' The |
| NMFS has established numerical limits on live takes, lethal takes causally |
| related to plant operation, and lethal takes not related to plant |
| operations. |
| |
| "The NMFS must be notified within five days whenever: |
| |
| a. The 40th non-lethal take occurs in the biennial period, or |
| b. The third causally related mortality occurs in the biennial period, or |
| c. The sixth non-causally related mortality occurs in the biennial |
| period. |
| |
| "The current biennial period for monitoring sea turtle takes began January |
| 1, 2001. |
| |
| "Thus, in accordance with Crystal Unit #3 Administrative Instruction 571, |
| Sea Turtle Rescue and Handling Guidance, the NMFS must be notified within |
| five days. |
| |
| "In accordance with Crystal River Unit #3 Compliance Procedure 151, External |
| Reporting Requirements, this 40th non-lethal sea turtle take is Reportable |
| as a 4-Hour Report under 10 CFR 50.72(b)(2)(xi) as this event is related to |
| the protection of the environment for which a notification to other |
| government agencies has been or will be made." |
| |
| The licensee will inform the NRC resident inspector. |
| |
| * * * UPDATE 0944EDT ON 4/10/01 FROM R. SWEENEY TO S. SANDIN * * * |
| |
| "On April 10, 2001 at 0859 the 41st non-lethal sea turtle take in the |
| biennial period occurred." |
| |
| The licensee informed the NRC resident inspector. Notified R2DO(Julian). |
| |
| ***** UPDATE RECEIVED AT 0911 ON 04/17/01 FROM CHRISTOPHER PELLERIN TO
LEIGH |
| TROCINE ***** |
| |
| The 42nd, non-lethal, sea turtle take in the biennial period occurred at |
| 0810 on April 17, 2001. |
| |
| The licensee notified the NRC resident inspector. The NRC operations |
| officer notified the R2DO (Ernstes). |
| |
| * * * UPDATE 1125 EDT ON 5/1/01 FROM DAVID SCHULKER TO FANGIE JONES * * * |
| |
| "On May 1, 2001 at 0805 a turtle was identified as the 43rd rescued, live |
| sea turtle in this biennial period. This sea turtle will be kept for a |
| short observation period and then safely returned to the environment." |
| |
| The licensee will inform the NRC Resident Inspector and the National |
| Wildlife and Fisheries Service. Notified R2DO(Jay Henson). |
| |
| * * * UPDATE ON 5/29/01 BY FERGUSON TO SANDIN * * * |
| |
| On May 29, 2001 at 0943 two turtles were identified as the 44th and 45th |
| rescued, live Sea turtles in this biennial period. These healthy sea turtles |
| will be kept for a short observation period and then safely returned to the |
| environment. |
| |
| This is Reportable as a 4-Hour Report under 10 CFR 50.72 (b) (2) (xi) as |
| this event is related to the protection of the environment for which a |
| notification to other government agencies has been or will be made. This is |
| an update to event 37902. |
| |
| The NRC Resident Inspector was notified. The REG2 RDO(Barr) was informed. |
| |
| * * * UPDATE 2014 EDT 6/4/2001 FROM RAWLS TAKEN BY STRANSKY * * * |
| |
| On June 4, 2001 at 1815, the 46th non-lethal sea turtle (Kemp's Ridley) take |
| in the biennial period occurred. The license has informed the NRC resident |
| inspector. Notified R2DO (Barr). |
| |
| * * * UPDATE 1315EDT ON 6/10/01 FROM CHARLES J. MORRIS TO S. SANDIN * * * |
| |
| On June 10, 2001 at 1100, the 47th non-lethal sea turtle take in the |
| biennial period occurred. The license has informed the NRC resident |
| inspector. Notified R2DO (Bonser). |
| |
| * * * UPDATE 0952 ON 8/20/2001 FROM FERGUSON TAKEN BY STRANSKY * * * |
| |
| On August 20, 2001 at 0815, the 48th non-lethal sea turtle take in the |
| biennial period occurred. The licensee as informed the NRC resident |
| inspector. Notified R2DO (Payne). |
| |
| * * * UPDATE 1216 ON 9/3/01 BY SCHULKER TO GOULD * * * |
| |
| On September 3, 2001 at 0845 a turtle was identified as the 49th rescued, |
| live sea turtle in this biennial period. This turtle has an injury to the |
| lower jaw and is being transported to the Clearwater Marine Science Station |
| for treatment. It has not been determined at this time if the injury is |
| casually related to Crystal River Operations. |
| |
| This is Reportable as a 4-Hour Report under 10 CFR 50.72 (b) (2) (xi) as |
| this event is related to the protection of the environment for which a |
| notification to other government agencies has been or will be made. This is |
| an update to event 37902. |
| |
| The NRC Resident Inspector and other government agencies will be notified. |
| |
| Notified Reg 2 RDO(Lesser) |
| |
| ***** UPDATE FROM RICHARD SWEENEY TO LEIGH TROCINE AT 0910 ON 10/28/01 |
| ***** |
| |
| The following text is a portion of a facsimile received from the licensee: |
| |
| "On October 28, 2001, at 0030, a turtle was identified as the 50th rescued, |
| live sea turtle in this biennial period. This is Reportable as a 4-Hour |
| Report under 10 CFR 50.72(b)(2)(xi) as this event is related to the |
| protection of the environment for which a notification to other government |
| agencies has been or will be made." |
| |
| The licensee plans to notify the national Marine and Fishery Services and |
| the NRC resident inspector. The NRC operations officer notified the Region |
| 2 Incident Response Center (McCree). |
| |
| ***** UPDATE FROM CURTIS McKEOWN TO JOHN MacKINNON AT 1005 ON 10/30/01 |
| ***** |
| |
| The following text is a portion of a facsimile received from the licensee: |
| |
| "On October 30, 2001, at 0826, two turtles were identified as the 51st and |
| 52nd rescued, live sea turtles in this biennial period. Additionally, a |
| turtle rescued on October 30, 2001, has been identified as the 53rd live sea |
| turtle rescued in this biennial period." |
| |
| "This is Reportable as a 4-Hour Report under 10 CFR 50.72(b)(2)(xi) as this |
| event is related to the protection of the environment for which a |
| notification to other government agencies has been or will be made." |
| |
| The licensee notified the NRC resident inspector and plans to notify the |
| national Marine and Fishery Services. The NRC operations officer notified |
| the Region 2 Incident Response Center (Loren Plisco). |
| |
| **** UPDATE FROM CURTIS McKEOWN John MacKinnon AT 1052 ON 11/01/01 ***** |
| |
| "On November 01, 2001 at 0916 a turtle was identified as the 54 the rescued, |
| live sea turtle in this biennial period. This is reportable as a 4-hour |
| report under 10 CFR 50.72(b)(2)(xi) as this event is related to the |
| protection of the environment for which a notification to other government |
| agencies has been or will be made. This is an update to event 37902." |
| R2IRC notified. |
| |
| The licensee notified the NRC Resident Inspector of this event. |
| |
| ***** UPDATE FROM BRYAN FERGUSON TO LEIGH TROCINE AT 0938 ON 11/03/01 |
| ***** |
| |
| The following text is a portion of a facsimile received from the licensee: |
| |
| "On November 3, 2001, at 0840, a green sea turtle was identified as the 55th |
| rescued, live sea turtle in this biennial period. This is Reportable as a |
| 4-Hour Report under 10 CFR 50.72(b)(2)(xi) as this event is related to the |
| protection of the environment for which a notification to other government |
| agencies has been or will be made. [...]" |
| |
| The licensee plans to notify the national Marine and Fishery Services and |
| the NRC resident inspector. The NRC operations officer notified the Region |
| 2 Incident Response Center (Ken Barr). |
| |
| ***** UPDATE FROM RICKY RAWLS TO LEIGH TROCINE AT 1126 ON 11/04/01 ***** |
| |
| The following text is a portion of a facsimile received from the licensee: |
| |
| "On November 3, 2001, at 1035, two sea turtles were identified as Kemp's |
| Ridley sea turtles. This is Crystal River Unit 3['s] (CR-3) 56th and 57th |
| rescue of live sea turtles in this biennial period. This is Reportable as a |
| 4-Hour Report under 10 CFR 50.72(b)(2)(xi) as this event is related to the |
| protection of the environment for which a notification to other government |
| agencies has been or will be made. [...]" |
| |
| The licensee plans to notify the national Marine and Fishery Services and |
| the NRC resident inspector. The NRC operations officer notified the Region |
| 2 Incident Response Center (Jim Hufham). |
| |
| * * * UPDATE 1046 EST ON 11/6/01 FROM RICK SWEENEY TO FANGIE JONES * * * |
| |
| "On November 06, 2001 at 0905, a sea turtle was identified as Kemp's Ridley |
| sea turtle. This is Crystal River Unit 3 (CR-3) 58th rescue of a live sea |
| turtle in this biennial period. This is reportable as a 4-Hour Report under |
| 10 CFR 50.72 (b) (2) (xi) as this event is related to the protection of the |
| environment for which a notification to other government agencies has been |
| or will be made. This is an update to event 37902." |
| |
| The licensee notified the NRC Resident Inspector. The R2DO (Caudle Julian) |
| was notified. |
| |
| * * * UPDATE 1149 11/11/01 FROM SCHULKER TAKEN BY STRANSKY * * * |
| |
| "On November 11, 2001 at 1045, a rescued sea turtle was Identified as a |
| Kemp's Ridley. This is the 59th rescue of a live sea turtle at Crystal River |
| Unit 3 (CR-3) in this biennial period. This is Reportable as a 4-Hour Report |
| under 10 CFR 50.72 (b) (2) (xi) as this event is related to the protection |
| of the environment for which a notification to other government agencies has |
| been or will be made. This is an update to event 37902." |
| |
| The licensee informed the NRC resident inspector. Notified R2 IRC. |
| |
| * * * UPDATE ON 11/17/01 @ 0846 BY SCHULKER TO GOULD * * * |
| |
| On November 17, 2001 at 0815, a rescued sea turtle was identified as a |
| Kemp's Ridley. This is the 60th rescue of a live sea turtle at Crystal River |
| Unit 3 (CR-3) in this biennial period. This is Reportable as a 4-Hour Report |
| under 10 CFR 50.72 (b) (2) (xi) as this event is related to the protection |
| of the environment for which a notification to other government agencies has |
| been or will be made. This is an update to event 37902. |
| |
| The NRC Resident Inspector will be informed. Notified Reg 2 RDO Julian. |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 38506 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SOUTH TEXAS REGION: 4 |NOTIFICATION DATE: 11/16/2001|
| UNIT: [1] [] [] STATE: TX |NOTIFICATION TIME: 12:09[EST]|
| RXTYPE: [1] W-4-LP,[2] W-4-LP |EVENT DATE: 11/16/2001|
+------------------------------------------------+EVENT TIME: 10:15[CST]|
| NRC NOTIFIED BY: BOB SCARBOROUGH |LAST UPDATE DATE: 11/16/2001|
| HQ OPS OFFICER: LEIGH TROCINE +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |CHARLES MARSCHALL R4 |
|10 CFR SECTION: | |
|DDDD 73.71 UNSPECIFIED PARAGRAPH | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| DISCOVERY OF A COMPROMISE OF SAFEGUARDS INFORMATION |
| |
| The licensee reported the discovery of a compromise of safeguards |
| information in accordance with 10CFR73.71(b)(1). Immediate compensatory |
| measures were taken upon discovery. (Contact the NRC operations officer for |
| additional details). |
| |
| The licensee plans to notify the NRC resident inspector. |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 38509 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: WOLF CREEK REGION: 4 |NOTIFICATION DATE: 11/16/2001|
| UNIT: [1] [] [] STATE: KS |NOTIFICATION TIME: 17:53[EST]|
| RXTYPE: [1] W-4-LP |EVENT DATE: 11/16/2001|
+------------------------------------------------+EVENT TIME: 12:30[CST]|
| NRC NOTIFIED BY: FERGUSON |LAST UPDATE DATE: 11/16/2001|
| HQ OPS OFFICER: LEIGH TROCINE +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |CHARLES MARSCHALL R4 |
|10 CFR SECTION: | |
|AIND 50.72(b)(3)(v)(D) ACCIDENT MITIGATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| DISCOVERY THAT CERTAIN SAFETY-RELATED COMPONENTS COULD BECOME
SUBMERGED |
| DURING A POTENTIAL FLOODING SCENARIO |
| |
| The following text is a portion of a facsimile received from the licensee: |
| |
| "The Wolf Creek Nuclear Operating Corporation (WCNOC) is reviewing |
| calculations and assumptions regarding its flooding analysis. Internal room |
| flooding calculation FL-04 for Auxiliary Building Rooms 1206 and 1207 is |
| based on a maximum flood rate of 3500 gpm. Research into this maximum flood |
| rate indicates the value was based upon the required flow rate to the |
| Condensate Hotwell from the Condensate Storage Tank (CST). The non-safety |
| related 10" pipe which is routed through rooms 1206 [and] 1207 provides |
| water at a flow rate greater than 3500 gpm from the CST to the Condensate |
| Hotwell. Engineering review found that the subject rooms (1206 [and] 1207 |
| are connected) could flood given a Safe Shutdown Earthquake and a subsequent |
| double guillotine break of the non-safety related 10" line within the room. |
| Multiple trains of safety related equipment exist in this room, and are at |
| an elevation such that these components could become submerged during the |
| flooding. Subsequently, WCNOC is reporting this issue as an event or |
| condition that could have prevented the fulfillment of the safety function |
| of systems needed to mitigate the consequences of an accident." |
| |
| "Upon discovery, WCNOC has throttled valve AP-V012 Condensate Storage Tank |
| Outlet Isolation to one-third open, thereby eliminating the potential of |
| flooding in excess of the capability of the floor drain system in the |
| subject rooms given a Safe Shutdown Earthquake." |
| |
| The licensee notified the NRC resident inspector. |
+------------------------------------------------------------------------------+
.
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021