Event Notification Report for November 5, 2001
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
11/02/2001 - 11/05/2001
** EVENT NUMBERS **
37902 38435 38436 38458 38459 38463
.
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37902 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: CRYSTAL RIVER REGION: 2 |NOTIFICATION DATE: 04/09/2001|
| UNIT: [3] [] [] STATE: FL |NOTIFICATION TIME: 11:08[EDT]|
| RXTYPE: [3] B&W-L-LP |EVENT DATE: 04/09/2001|
+------------------------------------------------+EVENT TIME: 09:54[EDT]|
| NRC NOTIFIED BY: RICHARD SWEENEY |LAST UPDATE DATE: 11/04/2001|
| HQ OPS OFFICER: STEVE SANDIN +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |CAUDLE JULIAN R2 |
|10 CFR SECTION: | |
|APRE 50.72(b)(2)(xi) OFFSITE NOTIFICATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|3 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION TO THE NATIONAL MARINE AND FISHERIES SERVICE AS A
|
| RESULT OF THE ENDANGERED SEA TURTLES NON-LETHAL TAKE LIMIT BEING
EXCEEDED |
| |
| "On April 09, 2001 at 0940 the 40th non-lethal sea turtle take in the |
| biennial period occurred. |
| |
| "In accordance with Crystal River Unit #3 Operating License, Appendix B, |
| Environmental Protection Plan (Non-Radiological), 'Endangered or threatened |
| sea turtles shall be protected in accordance with the Incidental Take |
| Statement issued by the National Marine and Fisheries Service (NMFS).' The |
| NMFS has established numerical limits on live takes, lethal takes causally |
| related to plant operation, and lethal takes not related to plant |
| operations. |
| |
| "The NMFS must be notified within five days whenever: |
| |
| a. The 40th non-lethal take occurs in the biennial period, or |
| b. The third causally related mortality occurs in the biennial period, or |
| c. The sixth non-causally related mortality occurs in the biennial |
| period. |
| |
| "The current biennial period for monitoring sea turtle takes began January |
| 1, 2001. |
| |
| "Thus, in accordance with Crystal Unit #3 Administrative Instruction 571, |
| Sea Turtle Rescue and Handling Guidance, the NMFS must be notified within |
| five days. |
| |
| "In accordance with Crystal River Unit #3 Compliance Procedure 151, External |
| Reporting Requirements, this 40th non-lethal sea turtle take is Reportable |
| as a 4-Hour Report under 10 CFR 50.72(b)(2)(xi) as this event is related to |
| the protection of the environment for which a notification to other |
| government agencies has been or will be made." |
| |
| The licensee will inform the NRC resident inspector. |
| |
| * * * UPDATE 0944EDT ON 4/10/01 FROM R. SWEENEY TO S. SANDIN * * * |
| |
| "On April 10, 2001 at 0859 the 41st non-lethal sea turtle take in the |
| biennial period occurred." |
| |
| The licensee informed the NRC resident inspector. Notified R2DO(Julian). |
| |
| ***** UPDATE RECEIVED AT 0911 ON 04/17/01 FROM CHRISTOPHER PELLERIN TO
LEIGH |
| TROCINE ***** |
| |
| The 42nd, non-lethal, sea turtle take in the biennial period occurred at |
| 0810 on April 17, 2001. |
| |
| The licensee notified the NRC resident inspector. The NRC operations |
| officer notified the R2DO (Ernstes). |
| |
| * * * UPDATE 1125 EDT ON 5/1/01 FROM DAVID SCHULKER TO FANGIE JONES * * * |
| |
| "On May 1, 2001 at 0805 a turtle was identified as the 43rd rescued, live |
| sea turtle in this biennial period. This sea turtle will be kept for a |
| short observation period and then safely returned to the environment." |
| |
| The licensee will inform the NRC Resident Inspector and the National |
| Wildlife and Fisheries Service. Notified R2DO(Jay Henson). |
| |
| * * * UPDATE ON 5/29/01 BY FERGUSON TO SANDIN * * * |
| |
| On May 29, 2001 at 0943 two turtles were identified as the 44th and 45th |
| rescued, live Sea turtles in this biennial period. These healthy sea turtles |
| will be kept for a short observation period and then safely returned to the |
| environment. |
| |
| This is Reportable as a 4-Hour Report under 10 CFR 50.72 (b) (2) (xi) as |
| this event is related to the protection of the environment for which a |
| notification to other government agencies has been or will be made. This is |
| an update to event 37902. |
| |
| The NRC Resident Inspector was notified. The REG2 RDO(Barr) was informed. |
| |
| * * * UPDATE 2014 EDT 6/4/2001 FROM RAWLS TAKEN BY STRANSKY * * * |
| |
| On June 4, 2001 at 1815, the 46th non-lethal sea turtle (Kemp's Ridley) take |
| in the biennial period occurred. The license has informed the NRC resident |
| inspector. Notified R2DO (Barr). |
| |
| * * * UPDATE 1315EDT ON 6/10/01 FROM CHARLES J. MORRIS TO S. SANDIN * * * |
| |
| On June 10, 2001 at 1100, the 47th non-lethal sea turtle take in the |
| biennial period occurred. The license has informed the NRC resident |
| inspector. Notified R2DO (Bonser). |
| |
| * * * UPDATE 0952 ON 8/20/2001 FROM FERGUSON TAKEN BY STRANSKY * * * |
| |
| On August 20, 2001 at 0815, the 48th non-lethal sea turtle take in the |
| biennial period occurred. The licensee as informed the NRC resident |
| inspector. Notified R2DO (Payne). |
| |
| * * * UPDATE 1216 ON 9/3/01 BY SCHULKER TO GOULD * * * |
| |
| On September 3, 2001 at 0845 a turtle was identified as the 49th rescued, |
| live sea turtle in this biennial period. This turtle has an injury to the |
| lower jaw and is being transported to the Clearwater Marine Science Station |
| for treatment. It has not been determined at this time if the injury is |
| casually related to Crystal River Operations. |
| |
| This is Reportable as a 4-Hour Report under 10 CFR 50.72 (b) (2) (xi) as |
| this event is related to the protection of the environment for which a |
| notification to other government agencies has been or will be made. This is |
| an update to event 37902. |
| |
| The NRC Resident Inspector and other government agencies will be notified. |
| |
| Notified Reg 2 RDO(Lesser) |
| |
| ***** UPDATE FROM RICHARD SWEENEY TO LEIGH TROCINE AT 0910 ON 10/28/01 |
| ***** |
| |
| The following text is a portion of a facsimile received from the licensee: |
| |
| "On October 28, 2001, at 0030, a turtle was identified as the 50th rescued, |
| live sea turtle in this biennial period. This is Reportable as a 4-Hour |
| Report under 10 CFR 50.72(b)(2)(xi) as this event is related to the |
| protection of the environment for which a notification to other government |
| agencies has been or will be made." |
| |
| The licensee plans to notify the national Marine and Fishery Services and |
| the NRC resident inspector. The NRC operations officer notified the Region |
| 2 Incident Response Center (McCree). |
| |
| ***** UPDATE FROM CURTIS McKEOWN TO JOHN MacKINNON AT 1005 ON 10/30/01 |
| ***** |
| |
| The following text is a portion of a facsimile received from the licensee: |
| |
| "On October 30, 2001, at 0826, two turtles were identified as the 51st and |
| 52nd rescued, live sea turtles in this biennial period. Additionally, a |
| turtle rescued on October 30, 2001, has been identified as the 53rd live sea |
| turtle rescued in this biennial period." |
| |
| "This is Reportable as a 4-Hour Report under 10 CFR 50.72(b)(2)(xi) as this |
| event is related to the protection of the environment for which a |
| notification to other government agencies has been or will be made." |
| |
| The licensee notified the NRC resident inspector and plans to notify the |
| national Marine and Fishery Services. The NRC operations officer notified |
| the Region 2 Incident Response Center (Loren Plisco). |
| |
| **** UPDATE FROM CURTIS McKEOWN John MacKinnon AT 1052 ON 11/01/01 ***** |
| |
| "On November 01, 2001 at 0916 a turtle was identified as the 54 the rescued, |
| live sea turtle in this biennial period. This is reportable as a 4-hour |
| report under 10 CFR 50.72(b)(2)(xi) as this event is related to the |
| protection of the environment for which a notification to other government |
| agencies has been or will be made. This is an update to event 37902." |
| R2IRC notified. |
| |
| The licensee notified the NRC Resident Inspector of this event. |
| |
| ***** UPDATE FROM BRYAN FERGUSON TO LEIGH TROCINE AT 0938 ON 11/03/01 |
| ***** |
| |
| The following text is a portion of a facsimile received from the licensee: |
| |
| "On November 3, 2001, at 0840, a green sea turtle was identified as the 55th |
| rescued, live sea turtle in this biennial period. This is Reportable as a |
| 4-Hour Report under 10 CFR 50.72(b)(2)(xi) as this event is related to the |
| protection of the environment for which a notification to other government |
| agencies has been or will be made. [...]" |
| |
| The licensee plans to notify the national Marine and Fishery Services and |
| the NRC resident inspector. The NRC operations officer notified the Region |
| 2 Incident Response Center (Ken Barr). |
| |
| ***** UPDATE FROM RICKY RAWLS TO LEIGH TROCINE AT 1126 ON 11/04/01 ***** |
| |
| The following text is a portion of a facsimile received from the licensee: |
| |
| "On November 3, 2001, at 1035, two sea turtles were identified as Kemp's |
| Ridley sea turtles. This is Crystal River Unit 3['s] (CR-3) 56th and 57th |
| rescue of live sea turtles in this biennial period. This is Reportable as a |
| 4-Hour Report under 10 CFR 50.72(b)(2)(xi) as this event is related to the |
| protection of the environment for which a notification to other government |
| agencies has been or will be made. [...]" |
| |
| The licensee plans to notify the national Marine and Fishery Services and |
| the NRC resident inspector. The NRC operations officer notified the Region |
| 2 Incident Response Center (Jim Hufham). |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 38435 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SURRY REGION: 2 |NOTIFICATION DATE: 10/28/2001|
| UNIT: [1] [] [] STATE: VA |NOTIFICATION TIME: 01:05[EST]|
| RXTYPE: [1] W-3-LP,[2] W-3-LP |EVENT DATE: 10/28/2001|
+------------------------------------------------+EVENT TIME: 00:15[EDT]|
| NRC NOTIFIED BY: ALLEN HARROW |LAST UPDATE DATE: 11/02/2001|
| HQ OPS OFFICER: LEIGH TROCINE +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |BOB HAAG, REGION 2 IRC |
|10 CFR SECTION: |WILLIAM BECKNER NRR |
|ADEG 50.72(b)(3)(ii)(A) DEGRADED CONDITION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N N 0 Refueling |0 Refueling |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| DISCOVERY OF APPARENT THROUGH-WALL INDICATIONS ON CONTROL ROD DRIVE
|
| MECHANISM PENETRATIONS |
| |
| The following text is a portion of a facsimile received from the licensee: |
| |
| "Following shutdown for a scheduled refueling outage, Surry Unit 1 performed |
| a visual inspection of the reactor vessel control rod drive mechanism (CRDM) |
| penetrations per NRC Bulletin 2001-01." |
| |
| "At approximately 0015 on October 28, 2001, apparent through-wall |
| indications were identified on CRDM penetrations 27 and 40. The inspection |
| is not yet complete. This condition did not pose a significant safety risk |
| during plant operation. This is being reported as a non-emergency (8-hour |
| report in accordance with 10 CFR 50.72(b)(3)(ii)(A) and |
| 50.73(a)(2)(ii)(A)." |
| |
| The licensee stated that the unit is currently defueled. |
| |
| The licensee notified the NRC resident inspector. |
| |
| * * * UPDATE ON 11/2/01 @ 0338 BY HILBERT-SEMMES TO GOULD * * * UPDATE |
| |
| At approximately 0220 hours on November 2, 2001, additional indications were |
| identified as having flaws that are not acceptable under ASME Section XI |
| IWB-3600 on penetrations 65, 47, and 69. Two previously identified |
| indications were previously reported in this event. The inspection of all |
| CRDM penetrations is now complete with disposition of one penetration still |
| underway. This condition did not pose a significant safety risk during |
| plant operation. This is being reported as an update. |
| |
| The NRC Resident Inspector was notified. The Reg 2 IRC Manager was |
| notified. |
| |
| ***** UPDATE FROM LISA HILBERT-SEMMES TO LEIGH TROCINE AT 2357 ON 11/02/01 |
| ***** |
| |
| The following text is a portion of a facsimile received from the licensee: |
| |
| "At approximately 2250 hours on November 2, 2001, an additional CRDM |
| penetration (location number 18) was identified as having flaws that are not |
| acceptable under ASME Section XI IWB-3600. Five previously identified |
| penetrations were reported [...]. This condition did not pose a significant |
| safety risk during plant operation. This is being reported as a |
| non-emergency 8-hour report in accordance with 10 CFR 50.72(b)(3)(ii)(A) and |
| 50.73(a)(2)(ii)(A), a condition that results in a principal safety barrier |
| being seriously degraded." |
| |
| The licensee notified the NRC resident inspector. The NRC operations |
| officer notified the Region 2 Incident Response Center (Steve Rudisail) and |
| NRR EO (John Zwolinski). |
+------------------------------------------------------------------------------+
.
!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 38436 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: VERMONT YANKEE REGION: 1 |NOTIFICATION DATE: 10/29/2001|
| UNIT: [1] [] [] STATE: VT |NOTIFICATION TIME: 16:32[EST]|
| RXTYPE: [1] GE-4 |EVENT DATE: 10/26/2001|
+------------------------------------------------+EVENT TIME: [EST]|
| NRC NOTIFIED BY: JIM BROOKS |LAST UPDATE DATE: 11/02/2001|
| HQ OPS OFFICER: BOB STRANSKY +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |R1 IRC TEAM MANAGER R1 |
|10 CFR SECTION: | |
|ACOM 50.72(b)(3)(xiii) LOSS COMM/ASMT/RESPONSE| |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| SPDS UNAVAILABLE AT EOF |
| |
| The licensee reported that a computer system upgrade performed on 10/26/01 |
| rendered the SPDS (safety parameter display system) inaccessible from the |
| EOF. The condition was discovered on 10/29/01. The condition has since been |
| repaired. The NRC resident inspector has been informed of this condition by |
| the licensee. |
| |
| * * * UPDATE 1431EST ON 11/2/01 FROM JOHN TWAROG TO S. SANDIN * * * |
| |
| The licensee is retracting this report based on the following: |
| |
| "On Oct. 29, 2001 Vermont Yankee reported to the NRC, via Event Number |
| 38436, the loss of the EOF SPDS computers since Oct. 25, 2001. Preliminary |
| investigation identified the loss of the computers was due to an upgrade to |
| the company's computer network performed on Oct. 25. Further investigation |
| on Oct. 30 revealed the EOF SPDS was only unavailable for approximately 3 |
| hours while the actual upgrade was being performed. This notification serves |
| as retraction of a prior 10 CFR 50.72 notification regarding the loss of the |
| EOF SPDS computers." |
| |
| The licensee informed the NRC Resident Inspector. Notified R1IRC. |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 38458 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: COOPER REGION: 4 |NOTIFICATION DATE: 11/02/2001|
| UNIT: [1] [] [] STATE: NE |NOTIFICATION TIME: 09:54[EST]|
| RXTYPE: [1] GE-4 |EVENT DATE: 11/02/2001|
+------------------------------------------------+EVENT TIME: 03:25[CST]|
| NRC NOTIFIED BY: WHEELER |LAST UPDATE DATE: 11/02/2001|
| HQ OPS OFFICER: CHAUNCEY GOULD +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |BLAIR SPITZBERG R4 |
|10 CFR SECTION: | |
|AIND 50.72(b)(3)(v)(D) ACCIDENT MITIGATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 94 Power Operation |94 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| BOTH REACTOR BUILDING TO TORUS VACUUM BREAKERS WERE PREVENTED FROM
|
| RESPONDING TO A REACTOR BUILDING TO TORUS DIFFERENTIAL PRESSURE
|
| |
| At 0325 CST, it was identified that the switches for TORUS VACUUM RELIEF |
| valves PC-AOV-243AV and PC-AOV-244AV were in the closed position. With the |
| switches in the closed position, the valves would not respond to a |
| differential pressure between the Reactor Building and Torus as required by |
| SR 3.6.1.7.3. The switches had been placed in the closed position for |
| performance of LLRT on penetration X-205. The valves were declared |
| inoperable and LCO 3.6.1.7 Condition D was entered. The required action for |
| this condition is to restore all vacuum breakers in one line to operable |
| status within 1 hour. If the valves are not restored to operable, Action E |
| is entered, which requires the plant to be in Mode 3 in 12 hours and Mode 4 |
| in 36 hours. The valve switches had been placed in this position as part of |
| a clearance order issued at 2357. |
| |
| At 0342 CST, the switches for the Torus Vacuum Relief valves were returned |
| to the Auto position, and the valves were declared operable as vacuum |
| breakers. The LCO 3.6.1.7 Condition D was exited. |
| |
| The function of the Reactor building to Torus vacuum breakers is to relieve |
| vacuum when primary containment depressurizes below Reactor Building |
| pressure. With the switches in the closed position, the valves would not |
| respond to a situation where a significant negative pressure existed between |
| the Reactor Building and Torus. A negative differential pressure is caused |
| by rapid depressurization of the drywell. Events that cause this rapid |
| depressurization are cooling cycles, primary containment spray actuation, |
| and steam condensation in the event of a primary system rupture. The |
| Reactor building to Torus vacuum breakers prevent an excessive negative |
| differential pressure across the primary containment boundary. |
| |
| This event was determined to be reportable on 11-2-01 at 0430 CST after |
| review of NUREG 1022 and design basis information. |
| |
| The NRC Resident Inspector was notified. |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|Other Nuclear Material |Event Number: 38459 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: NTH CONSULTANTS |NOTIFICATION DATE: 11/02/2001|
|LICENSEE: NTH CONSULTANTS |NOTIFICATION TIME: 15:07[EST]|
| CITY: FARMINGTON HILLS REGION: 3 |EVENT DATE: 11/02/2001|
| COUNTY: STATE: MI |EVENT TIME: [EST]|
|LICENSE#: 21-14894-01 AGREEMENT: N |LAST UPDATE DATE: 11/02/2001|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |MICHAEL JORDAN R3 |
| |BRIAN SMITH NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: JIM PARSONS | |
| HQ OPS OFFICER: STEVE SANDIN | |
+------------------------------------------------+ |
|EMERGENCY CLASS: NON EMERGENCY | |
|10 CFR SECTION: | |
|BAB1 20.2201(a)(1)(i) LOST/STOLEN LNM>1000X | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| TROXLER GAUGE DISCOVERED MISSING DURING ROUTINE INVENTORY |
| |
| During a routine physical inventory, a Troxler Model 3411B (upgraded 3401B), |
| S/N 16990, was discovered missing from the Farmington Hills, MI, main |
| office. The gauge which contains 8 millicuries Cs-137 and 40 millicuries |
| Americium-241/Be, was logged out from the Grand Rapids office on 8/31/01 as |
| a return to the main office for repairs. The main office has no record of |
| the shipment. The local police department in Grand Rapids has been informed |
| of the missing gauge. The licensee is continuing their investigation. |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 38463 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: VERMONT YANKEE REGION: 1 |NOTIFICATION DATE: 11/04/2001|
| UNIT: [1] [] [] STATE: VT |NOTIFICATION TIME: 13:44[EST]|
| RXTYPE: [1] GE-4 |EVENT DATE: 11/04/2001|
+------------------------------------------------+EVENT TIME: 11:42[EST]|
| NRC NOTIFIED BY: DENNIS MAY |LAST UPDATE DATE: 11/04/2001|
| HQ OPS OFFICER: STEVE SANDIN +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |R1 IRC TEAM MANAGER R1 |
|10 CFR SECTION: | |
|ADEG 50.72(b)(3)(ii)(A) DEGRADED CONDITION | |
|AINC 50.72(b)(3)(v)(C) POT UNCNTRL RAD REL | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| LOSS OF CONTAINMENT INTEGRITY |
| |
| "At 0525[EST] the Control Room received a low flow alarm as a result of a |
| leaking 1/4 inch fitting on the 'B' Hydrogen/Oxygen analyzer. At 1142[EST] |
| it was determined, as a result of a leak rate test, that the maximum |
| allowable test leak rate (La) was potentially exceeded. The system was |
| isolated within 5 minutes of receiving the alarm. A 24 hour hour shutdown |
| LCO (TS 3.7.A.8) was entered at 0525[EST] and exited at 0530[EST]." |
| |
| The licensee will inform both the State of Vermont and the NRC Resident |
| Inspector. |
| |
| Hoo Note: A similar problem related to this particular monitor was reported |
| on 10/30/01 - see event #38444. |
+------------------------------------------------------------------------------+
.