The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.
Event Notification Report for November 2, 2001
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
11/01/2001 - 11/02/2001
** EVENT NUMBERS **
38435 38453 38454 38457
.
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 38435 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SURRY REGION: 2 |NOTIFICATION DATE: 10/28/2001|
| UNIT: [1] [] [] STATE: VA |NOTIFICATION TIME: 01:05[EST]|
| RXTYPE: [1] W-3-LP,[2] W-3-LP |EVENT DATE: 10/28/2001|
+------------------------------------------------+EVENT TIME: 00:15[EDT]|
| NRC NOTIFIED BY: ALLEN HARROW |LAST UPDATE DATE: 11/02/2001|
| HQ OPS OFFICER: LEIGH TROCINE +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |BOB HAAG, REGION 2 IRC |
|10 CFR SECTION: |WILLIAM BECKNER NRR |
|ADEG 50.72(b)(3)(ii)(A) DEGRADED CONDITION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N N 0 Refueling |0 Refueling |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| DISCOVERY OF APPARENT THROUGH-WALL INDICATIONS ON CONTROL ROD DRIVE
|
| MECHANISM PENETRATIONS |
| |
| The following text is a portion of a facsimile received from the licensee: |
| |
| "Following shutdown for a scheduled refueling outage, Surry Unit 1 performed |
| a visual inspection of the reactor vessel control rod drive mechanism (CRDM) |
| penetrations per NRC Bulletin 2001-01." |
| |
| "At approximately 0015 on October 28, 2001, apparent through-wall |
| indications were identified on CRDM penetrations 27 and 40. The inspection |
| is not yet complete. This condition did not pose a significant safety risk |
| during plant operation. This is being reported as a non-emergency (8-hour |
| report in accordance with 10 CFR 50.72(b)(3)(ii)(A) and |
| 50.73(a)(2)(ii)(A)." |
| |
| The licensee stated that the unit is currently defueled. |
| |
| The licensee notified the NRC resident inspector. |
| |
| * * * UPDATE ON 11/2/01 @ 0338 BY HILBERT-SEMMES TO GOULD * * * UPDATE |
| |
| Following shutdown for a scheduled refueling outage, Surry Unit 1 performed |
| a visual inspection of the reactor vessel Control Rod Drive Mechanism (CRDM) |
| penetrations per NRC Bulletin 2001-01. |
| |
| At approximately 0220 hours on November 2, 2001, additional indications were |
| identified as having flaws that are not acceptable under ASME Section XI |
| IWB-3600 on penetrations 65, 47, and 69. Two previously identified |
| indications were previously reported in this event. The inspection of all |
| CRDM penetrations is now complete with disposition of one penetration still |
| underway. This condition did not pose a significant safety risk during |
| plant operation. This is being reported as an update. |
| |
| The NRC Resident Inspector was notified. The Reg 2 IRC Manager was |
| notified. |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 38453 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: FARLEY REGION: 2 |NOTIFICATION DATE: 11/01/2001|
| UNIT: [1] [] [] STATE: AL |NOTIFICATION TIME: 09:47[EST]|
| RXTYPE: [1] W-3-LP,[2] W-3-LP |EVENT DATE: 10/31/2001|
+------------------------------------------------+EVENT TIME: [CST]|
| NRC NOTIFIED BY: HAWKINS |LAST UPDATE DATE: 11/01/2001|
| HQ OPS OFFICER: CHAUNCEY GOULD +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |R2 IRC TEAM MANAGER R2 |
|10 CFR SECTION: | |
|NINF INFORMATION ONLY | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N N 0 Hot Standby |0 Hot Standby |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| CONTROL RODS DID NOT FULLY INSERT DURING CONTROL ROD TEST |
| |
| On October 31 and November 1, 2001 following reactor vessel assembly and |
| heat up, control rod drop testing was performed in mode 3. Rods N-9 and C-9 |
| did not fully insert into the dashpot region (24 steps) following |
| operability and trip testing. Rod J-13 exhibited similar characteristics |
| following operability and trip testing but shortly after trip testing it |
| fully inserted. Four other rods fully inserted but were slower than normal |
| in the dashpot region. All other control rods tested fully acceptable. The |
| Unit is currently cooling down and plans are under way to replace |
| unacceptable control rods as necessary. The Unit has remained borated above |
| the all rods out critical boron concentration since core reload and adequate |
| SDM exits. |
| |
| On October 06, 2001 Farley Unit 1 commenced a normal Unit shutdown to start |
| its 17th refueling outage. All control rods were fully inserted with no |
| problems. During insert and control rod changeout in the Unit 1 fuel pool |
| several control rods not scheduled to go back into the core experienced |
| binding in older fuel assemblies that prevented the rods from fully |
| inserting in the dashpot region of assemblies. Upon investigation of the |
| old control rods scheduled to be replaced axial cracks were observed by |
| visual exmination in several assemblies near the rod ends but above the rod |
| tips. This resulted in an inspection program for 18 older control rods |
| scheduled to go back into the core to confirm the acceptability for |
| continued use in cycle 18. Visual inspection and drag testing was performed |
| in the Unit 1 Spent Fuel. Westinghouse reviewed the test results and |
| confirmed the acceptability of 18 control rods for Cycle 18 use. |
| |
| The NRC Resident was notified. |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|Hospital |Event Number: 38454 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: ST BARNABAS MEDICAL CENTER |NOTIFICATION DATE: 11/01/2001|
|LICENSEE: ST BARNABAS MEDICAL CENTER |NOTIFICATION TIME: 10:36[EST]|
| CITY: LIVINGSTON REGION: 1 |EVENT DATE: 10/26/2001|
| COUNTY: STATE: NJ |EVENT TIME: [EST]|
|LICENSE#: 29-01608-03 AGREEMENT: N |LAST UPDATE DATE: 11/01/2001|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |R1 IRC TEAM MANAGER R1 |
| |FRED BROWN NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: GARELICK | |
| HQ OPS OFFICER: CHAUNCEY GOULD | |
+------------------------------------------------+ |
|EMERGENCY CLASS: NON EMERGENCY | |
|10 CFR SECTION: | |
|LADM 35.33(a) MED MISADMINISTRATION | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| MEDICAL MISADMINISTRATION DURING THERAPEUTIC TREATMENT REPORTED BY ST
|
| BARNABAS MEDICAL CENTER |
| |
| A patient undergoing the third therapeutic treatment received a dose to an |
| unintended treatment site due to an incorrect step size on a High Rate |
| Remote After Loader which was used in the treatment. This was the result of |
| human error. It was determined there will be no medical implications and |
| the patient will be notified. |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 38457 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: ARKANSAS NUCLEAR REGION: 4 |NOTIFICATION DATE: 11/01/2001|
| UNIT: [] [2] [] STATE: AR |NOTIFICATION TIME: 15:13[EST]|
| RXTYPE: [1] B&W-L-LP,[2] CE |EVENT DATE: 11/01/2001|
+------------------------------------------------+EVENT TIME: 12:30[CST]|
| NRC NOTIFIED BY: ALAN SMITH |LAST UPDATE DATE: 11/01/2001|
| HQ OPS OFFICER: STEVE SANDIN +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |BLAIR SPITZBERG R4 |
|10 CFR SECTION: | |
|ARPS 50.72(b)(2)(iv)(B) RPS ACTUATION - CRITICA| |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
| | |
|2 A/R Y 22 Power Operation |0 Hot Standby |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| AUTOMATIC REACTOR TRIP DURING CEA TROUBLESHOOTING FOR REASONS
UNKNOWN |
| |
| "While operating at full power at approximately 1010 CST on 11/01/2001, |
| Control Element Assembly (CEA) 43 dropped into the core for unknown reasons. |
| Reduction of reactor power began at approximately 1017. With reactor power |
| stable at approximately 22 percent, troubleshooting of the cause of the |
| CEA-43 drop was in progress at approximately 1230 CST when an automatic |
| reactor trip occurred. The reason for the trip is unknown. Plant response |
| to the trip was normal and uncomplicated. All CEAs fully inserted. There |
| were no ESF system actuations. The plant is stable in Hot Standby (Mode 3) |
| conditions with decay heat being removed via the Steam Generators to the |
| Main Condenser. No radiation releases occurred." |
| |
| The licensee informed the state and NRC Resident Inspector. |
+------------------------------------------------------------------------------+
.
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021