Skip to main content

The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.

Event Notification Report for October 16, 2001

                   
                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           10/15/2001 - 10/16/2001

                              ** EVENT NUMBERS **

38376  38388  38389  38390  38391  
.
+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   38376       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  TEXAS DEPARTMENT OF HEALTH           |NOTIFICATION DATE: 10/10/2001|
|LICENSEE:  LAW ENGINEERING AND ENVIRONMENTAL SER|NOTIFICATION TIME:
17:29[EDT]|
|    CITY:  DALLAS                   REGION:  4  |EVENT DATE:        10/10/2001|
|  COUNTY:                            STATE:  TX |EVENT TIME:             [CDT]|
|LICENSE#:  L02453                AGREEMENT:  Y  |LAST UPDATE DATE:  10/10/2001|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |LINDA HOWELL         R4      |
|                                                |C.W. (BILL) REAMER   NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  JAMES H. OGDEN, JR. (fax)    |                             |
|  HQ OPS OFFICER:  LEIGH TROCINE                |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT REGARDING DISCOVERY OF A LAW ENGINEERING AND   
      |
| ENVIRONMENTAL SERVICES GAUGE ON A RESIDENTIAL STREET BY AN EMPLOYEE
OF       |
| ANOTHER COMPANY                                                              |
|                                                                              |
| The following text is a portion of a facsimile received from the Texas       |
| Department of Health, Bureau of Radiation Control:                           |
|                                                                              |
| "Texas Incident No.:  I-7810"                                                |
|                                                                              |
| "License No.:  L02453"                                                       |
|                                                                              |
| "Licensee:  Law Engineering and Environmental Services, Houston, Texas (Fort |
| Worth Subsite)"                                                              |
|                                                                              |
| "Event date and time:  10/10/01  a.m."                                       |
|                                                                              |
| "Event location:  Dallas, Texas (exact location unknown at this time - gauge |
| was transported to 10722 North Stemmons Freeway, Dallas, Texas 75220[)]"     |
|                                                                              |
| "Event type:  Found Nuclear Density Gauge, Troxler 3411 B, Serial #11251"    |
|                                                                              |
| "Notifications:  Notified Troxler Electronic Labs, TDH Public Health Region  |
| 3 to pickup gauge and have leak tested."                                     |
|                                                                              |
| "Event description:  Gauge found in the middle of a residential street by an |
| employee of Giles Engineering, Texas License L04919-001.  Gauge was found to |
| be un-locked - both case and control rod.  The gauge was reported to be in   |
| the 'On' position.  No shipping papers were found in the case.  No warning   |
| stickers were reported to be on the exterior of the case.  Troxler Labs      |
| reports that the gauge was last seen by them over 2-years ago and was then   |
| owned by Austin Testing Engineers - no evidence of Licensure through this    |
| Agency.  Gauge was tracked to Law Engineering in Fort Worth.  TDH is holding |
| the gauge.  Will have leak test performed.  Licensee was unaware that the    |
| gauge was missing and could not immediately find if the gauge was assigned   |
| on a job for 10/10/01."                                                      |
|                                                                              |
| "Transport vehicle description:  None available at this time."               |
|                                                                              |
| "Media attention:  None"                                                     |
|                                                                              |
| (Contact the NRC operations officer for an agreement state point of          |
| contact.)                                                                    |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   38388       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  CALIFORNIA RADIATION CONTROL PRGM    |NOTIFICATION DATE:
10/15/2001|
|LICENSEE:  KRAZAN and ASSOCIATES                |NOTIFICATION TIME: 13:02[EDT]|
|    CITY:  CLOVIS                   REGION:  4  |EVENT DATE:        10/11/2001|
|  COUNTY:                            STATE:  CA |EVENT TIME:             [PDT]|
|LICENSE#:  4247-01               AGREEMENT:  Y  |LAST UPDATE DATE:  10/15/2001|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |BILL JONES           R4      |
|                                                |BRIAN SMITH          NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  KENT PRENDERGAST             |                             |
|  HQ OPS OFFICER:  FANGIE JONES                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT - STOLEN MOISTURE DENSITY GAUGE                       |
|                                                                              |
| "Thursday, 10/11/01 a Krazan and Associates employee, after working late     |
| took his portable moisture density gauge to his residence on Floyd Road in   |
| Modesto, California. The gauge was reportedly locked and chained to the rear |
| of his pickup truck , but was not covered. The gauge chain was reportedly    |
| cut and the gauge was stolen sometime between 9:00 PM and 6:00 AM on October |
| 12, 2001 by unknown persons. The gauge was a Troxler 3440 Serial Number      |
| 231711 containing approximately 10 millicuries of cesium 137 and 40          |
| millicuries of americium 241. The RSO indicated he will be placing an ad in  |
| the local newspaper offering a reward for the gauge. The RSO indicated that  |
| he has counseled his employee for breaking company rules by taking the gauge |
| to his residence which is against company policy and California              |
| regulations."                                                                |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38389       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: NINE MILE POINT          REGION:  1  |NOTIFICATION DATE: 10/15/2001|
|    UNIT:  [] [2] []                 STATE:  NY |NOTIFICATION TIME: 13:16[EDT]|
|   RXTYPE: [1] GE-2,[2] GE-5                    |EVENT DATE:        10/15/2001|
+------------------------------------------------+EVENT TIME:        09:59[EDT]|
| NRC NOTIFIED BY:  JOHN MANLY                   |LAST UPDATE DATE:  10/15/2001|
|  HQ OPS OFFICER:  FANGIE JONES                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |FRANK COSTELLO       R1      |
|10 CFR SECTION:                                 |                             |
|ACCS 50.72(b)(2)(iv)(A)  ECCS INJECTION         |                             |
|ARPS 50.72(b)(2)(iv)(B)  RPS ACTUATION - CRITICA|                             |
|AESF 50.72(b)(3)(iv)(A)  VALID SPECIF SYS ACTUAT|                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     A/R        Y       100      Power Operation  |0        Hot Shutdown     |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AUTOMATIC REACTOR SCRAM DUE TO MAIN STEAM ISOLATION FOR UNKNOWN
CAUSE        |
|                                                                              |
| Unit 2 was operating at 100% power, steady state, when the Main Steam        |
| Isolation Valves (MSIVs) fast closed causing a Reactor Protection System     |
| (RPS) full scram, all rods fully inserted.  The reactor feedwater pumps      |
| tripped on Reactor Vessel Water Level 8 due to controlling reactor pressure  |
| with Safety Relief Valves.  After the feedwater trip, reactor pressure was   |
| reduced to 550-650 psig so condensate booster pumps could inject to the      |
| Reactor Pressure Vessel (RPV).  At 1043 the Reactor Vessel Water Level 2 was |
| reached on the shrink from closure of the Safety Relief Valves.  This in     |
| turn caused a valid initiation and injection of the High Pressure Core Spray |
| (HPCS) and isolation of various containment isolation valves.                |
|                                                                              |
| Reactor vessel water level and pressure has been stabilized.  HPCS has been  |
| restored to standby.  The plant is stable in Mode 3.  The cause of the MSIV  |
| isolation is still under investigation and a normal post scram review is     |
| underway.                                                                    |
|                                                                              |
| The licensee notified the NRC Resident Inspector and will issue a media      |
| release.                                                                     |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38390       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SEABROOK                 REGION:  1  |NOTIFICATION DATE: 10/15/2001|
|    UNIT:  [1] [] []                 STATE:  NH |NOTIFICATION TIME: 14:31[EDT]|
|   RXTYPE: [1] W-4-LP                           |EVENT DATE:        10/15/2001|
+------------------------------------------------+EVENT TIME:        13:07[EDT]|
| NRC NOTIFIED BY:  CHRISTOPHER O'CONNOR         |LAST UPDATE DATE:  10/15/2001|
|  HQ OPS OFFICER:  FANGIE JONES                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |FRANK COSTELLO       R1      |
|10 CFR SECTION:                                 |                             |
|ARPS 50.72(b)(2)(iv)(B)  RPS ACTUATION - CRITICA|                             |
|AESF 50.72(b)(3)(iv)(A)  VALID SPECIF SYS ACTUAT|                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE  
|
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     A/R        Y       100      Power Operation  |0        Hot Standby      |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AUTOMATIC REACTOR TRIP DURING PERFORMANCE OF QUARTERLY ROD
OPERABILITY       |
| SURVEILLANCE                                                                 |
|                                                                              |
| The licensee reported that during a normal quarterly rod operability         |
| surveillance an automatic reactor trip occurred, all rods fully inserted.    |
| Preliminary investigation indicates that one rod dropped during rod motion   |
| causing a negative rate trip to occur.                                       |
|                                                                              |
| The Emergency Feedwater system actuated, as expected on a reactor trip, and  |
| is providing feedwater to the steam generators.  Excess heat is being        |
| rejected to the main condensers via the steam dumps.  No safety or relief    |
| valves opened during the transient.                                          |
|                                                                              |
| The plant is stable in Mode 3 and an investigation into the event is         |
| underway.                                                                    |
|                                                                              |
| The licensee notified the NRC Resident Inspector and will issue a media      |
| release.                                                                     |
+------------------------------------------------------------------------------+
.
+------------------------------------------------------------------------------+
|                                           |
|Fuel Cycle Facility                              |Event Number:   38391       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PORTSMOUTH GASEOUS DIFFUSION PLANT   |NOTIFICATION DATE:
10/15/2001|
|   RXTYPE: URANIUM ENRICHMENT FACILITY          |NOTIFICATION TIME: 16:34[EDT]|
| COMMENTS: 2 DEMOCRACY CENTER                   |EVENT DATE:        10/15/2001|
|           6903 ROCKLEDGE DRIVE                 |EVENT TIME:        10:30[EDT]|
|           BETHESDA, MD 20817    (301)564-3200  |LAST UPDATE DATE:  10/15/2001|
|    CITY:  PIKETON                  REGION:  3  +-----------------------------+
|  COUNTY:  PIKE                      STATE:  OH |PERSON          ORGANIZATION |
|LICENSE#:  GDP-2                 AGREEMENT:  N  |ANTON VEGEL          R3      |
|  DOCKET:  0707002                              |DON COOL             NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  JIM McCLEERY                 |                             |
|  HQ OPS OFFICER:  FANGIE JONES                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NBNL                     RESPONSE-BULLETIN      |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| 24 HOUR REPORT - NRC BULLETIN 91-01                                          |
|                                                                              |
| The following is a faxed report of finding in building X-330:                |
|                                                                              |
| During a building walk down, contaminated items in a category II staging     |
| area were observed to be closer than the NCSA plant-048 allowed. The PSS     |
| entered an anomalous condition. The items were moved to the appropriate      |
| spacing requirements. The anomalous condition was exited.                    |
|                                                                              |
| SAFETY SIGNIFICANCE OF EVENTS:                                               |
|                                                                              |
| The safety significance is low, The safe mass quantity is less than half of  |
| the minimum critical mass, in a spherical geometry. and with optimum         |
| moderation. The NCSE evaluated two items touching, these items were still    |
| separated, had little moderation present, and are not spherical.             |
|                                                                              |
| POTENTIAL CRITICALITY PATHWAYS INVOLVED (BRIEF SCENARIO[S] OF HOW            |
| CRITICALITY COULD OCCUR):                                                    |
|                                                                              |
| In order for a criticality to occur more spacing violations, to increase     |
| mass would have had to occur and additional moderating material would be     |
| required.                                                                    |
|                                                                              |
| CONTROLLED PARAMETERS (MASS, MODERATION, GEOMETRY, CONCENTRATION,
ETC.):     |
|                                                                              |
| Mass and spacing are controlled.                                             |
|                                                                              |
| ESTIMATED AMOUNT, ENRICHMENT, FORM OF LICENSED MATERIAL (INCLUDE
PROCESS     |
| LIMIT AND % WORST CASE OF CRITICAL MASS):                                    |
|                                                                              |
| Items involved were less than safe mass and enriched to 10% or less.         |
|                                                                              |
| NUCLEAR CRITICALITY SAFETY CONTROL(S) OR CONTROL SYSTEM(S) AND
DESCRIPTION   |
| OF THE FAILURES OR DEFICIENCIES:                                             |
|                                                                              |
| The controls were mass and spacing. Spacing was the control violated.        |
|                                                                              |
| CORRECTIVE ACTIONS TO RESTORE SAFETY SYSTEM AND WHEN EACH WAS
IMPLEMENTED:   |
|                                                                              |
| The items observed inside the spacing requirements were moved to required    |
| spacing requirements.                                                        |
|                                                                              |
| The licensee notified the NRC Resident Inspector and the DOE representative. |
+------------------------------------------------------------------------------+
.

Page Last Reviewed/Updated Wednesday, March 24, 2021

Page Last Reviewed/Updated Wednesday, March 24, 2021