Event Notification Report for September 24, 2001
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
09/21/2001 - 09/24/2001
** EVENT NUMBERS **
38302 38303 38304 38305 38307 38308
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 38302 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: CALIFORNIA RADIATION CONTROL PRGM |NOTIFICATION DATE: 09/21/2001|
|LICENSEE: MEDI-PHYSICS INC., dba NYCOMED AMERSH|NOTIFICATION TIME: 15:30[EDT]|
| CITY: San Diego REGION: 4 |EVENT DATE: 09/21/2001|
| COUNTY: STATE: CA |EVENT TIME: 11:00[PDT]|
|LICENSE#: 5796-37 AGREEMENT: Y |LAST UPDATE DATE: 09/21/2001|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |BILL JONES R4 |
| |SUSAN FRANT NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: ROBERT GREGER | |
| HQ OPS OFFICER: STEVE SANDIN | |
+------------------------------------------------+ |
|EMERGENCY CLASS: NON EMERGENCY | |
|10 CFR SECTION: | |
|NAGR AGREEMENT STATE | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT INVOLVING RAD CONTAMINATION DURING TRANSPORT |
| |
| "On August 24th at approximately 9:00 a.m. at the Medi-Physics facility |
| located at 4877 Mercury Street. |
| |
| "A courier for Medi-Physics brought back some empty ammo containers from the |
| morning deliveries. The containers were wiped upon receipt and it was |
| discovered that one of the containers had removable contamination on the top |
| of the container. From our phone conversation it appears that the level of |
| removable contamination was approximately 300,000 DPM/ 100 cm2. The material |
| was identified as Technetium-99. Medi-Physics will be submitting a letter |
| with the details to my attention. The RSO at the hospital was contacted and |
| he completed a survey to check for contamination at their facility. It is |
| not known at this time the results of that survey. The courier's feet and |
| the pedals of the vehicle also showed elevated levels of contamination." |
| |
| This information was reported to the San Diego Office on 9/21/01 at |
| approximately 1100PDT. CA Event Report Identification XCA 85. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 38303 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: NV DIV OF RAD HEALTH |NOTIFICATION DATE: 09/21/2001|
|LICENSEE: SUNRISE DIAGNOSTIC CENTER |NOTIFICATION TIME: 17:25[EDT]|
| CITY: LAS VEGAS REGION: 4 |EVENT DATE: 09/21/2001|
| COUNTY: STATE: NV |EVENT TIME: [PDT]|
|LICENSE#: 03-12-0395-02 AGREEMENT: Y |LAST UPDATE DATE: 09/21/2001|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |JOHN PELLET R4 |
| |ERIC LEEDS NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: STAN MARSHALL | |
| HQ OPS OFFICER: STEVE SANDIN | |
+------------------------------------------------+ |
|EMERGENCY CLASS: NON EMERGENCY | |
|10 CFR SECTION: | |
|NAGR AGREEMENT STATE | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT INVOLVING POTENTIAL MEDICAL MISADMINISTRATION |
| |
| "Malfunction of Leksell Gamma Knife patient table. Possible |
| misadministration to patient. Licensee is preparing a written report with |
| more detail, corrective action, etc. |
| |
| "Patient being treated in a Gamma Knife unit rolled up against the table and |
| table was unable to automatically retract from the Gamma Knife 'cave.' |
| Licensee personnel were able to enter the room and manually remove the |
| patient and table from the 'cave.' Personnel exposure estimated to be |
| between 3 mr and 20 mr. Gamma Knife manufacturer (Leksell) has also been |
| notified." |
| |
| Event Report ID No. NV-01-004. Event location Las Vegas, NV. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 38304 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: MCGUIRE REGION: 2 |NOTIFICATION DATE: 09/22/2001|
| UNIT: [1] [2] [] STATE: NC |NOTIFICATION TIME: 03:48[EDT]|
| RXTYPE: [1] W-4-LP,[2] W-4-LP |EVENT DATE: 09/22/2001|
+------------------------------------------------+EVENT TIME: 00:39[EDT]|
| NRC NOTIFIED BY: ERIC WILKINSON |LAST UPDATE DATE: 09/22/2001|
| HQ OPS OFFICER: FANGIE JONES +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |CHARLES CASTO R2 |
|10 CFR SECTION: | |
|APRE 50.72(b)(2)(xi) OFFSITE NOTIFICATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
|2 N Y 100 Power Operation |100 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION TO THE LOCAL AUTHORITIES DUE TO AN INCIDENT IN FRONT OF |
| THE PLANT |
| |
| The licensee's security department contacted the local police department |
| about an incident just outside the plant at the highway entrance about a |
| quarter mile from the protected area. |
| |
| The licensee notified the NRC Resident Inspector. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Fuel Cycle Facility |Event Number: 38305 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PORTSMOUTH GASEOUS DIFFUSION PLANT |NOTIFICATION DATE: 09/22/2001|
| RXTYPE: URANIUM ENRICHMENT FACILITY |NOTIFICATION TIME: 06:21[EDT]|
| COMMENTS: 2 DEMOCRACY CENTER |EVENT DATE: 09/22/2001|
| 6903 ROCKLEDGE DRIVE |EVENT TIME: 02:25[EDT]|
| BETHESDA, MD 20817 (301)564-3200 |LAST UPDATE DATE: 09/22/2001|
| CITY: PIKETON REGION: 3 +-----------------------------+
| COUNTY: PIKE STATE: OH |PERSON ORGANIZATION |
|LICENSE#: GDP-2 AGREEMENT: N |JOHN MADERA R3 |
| DOCKET: 0707002 |ERIC LEEDS NMSS |
+------------------------------------------------+RICHARD WESSMAN IRO |
| NRC NOTIFIED BY: ERICK SPAETH | |
| HQ OPS OFFICER: FANGIE JONES | |
+------------------------------------------------+ |
|EMERGENCY CLASS: NON EMERGENCY | |
|10 CFR SECTION: | |
|NBNL RESPONSE-BULLETIN | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| 4 HOUR REPORT - NRC BULLETIN 91-01 |
| |
| On 9/22/01 at 0225 hrs., operations personnel in the X-330 process building |
| discovered that a UO2F2 deposit with "Greater Than Safe Mass" (GSM) was no |
| longer being buffered with dry air or N2, to greater than or equal to 14 |
| psia. The deposit was located at 31-5, cell 6/8 drop. The buffer pressure |
| had been monitored from an adjacent cell 31-5-8. Block valves marked as open |
| on a pin chart, were found to be closed, thus isolating the deposit from the |
| monitoring cell. The GSM deposit pressure was verified to be 5.81 psia with |
| Maintenance and Test Equipment (M&TE). |
| |
| NCSA-0330_004.A06 requirement #8a states in part, "If there is a deposit |
| greater than a safe mass for systems conditions in the equipment, the |
| pressure in the equipment shall monitored each shift and if the pressure is |
| less than 14 psia it shall be adjusted with dry air or N2 to greater than 14 |
| psia within 12 hours." |
| |
| Buffer pressure was increased to greater than 14 psia at 0425 hours. |
| Remaining areas of the plant with similar conditions were checked and |
| verified to be compliant with the 14 psia Buffer pressure requirement. |
| |
| SAFETY SIGNIFICANCE OF EVENTS: |
| MODERATE, in this event the equipment was potentially without a buffer for 5 |
| months which is insufficient time to allow enough water to enter the pipe |
| and moderate the deposit to the level required to support a criticality. |
| |
| POTENTIAL CRITICALITY PATHWAYS INVOLVED (BRIEF SCENARIO[S] OF HOW |
| CRITICALITY COULD OCCUR): Sufficient moderation must be added to a deposit |
| at > safe mass to potentially create a critical configuration. This is |
| highly dependent on geometry and reflection conditions. |
| |
| CONTROLLED PARAMETERS (MASS, MODERATION, GEOMETRY, CONCENTRATION, FTC.): |
| In this event, moderation is the only available control, and it was not |
| maintained. Other parameters, like geometry and reflection, are assumed to |
| be optimum. |
| |
| ESTIMATED AMOUNT, ENRICHMENT, FORM OF LICENSED MATERIAL (INCLUDE PROCESS |
| LIMIT AND % WORST CASE OF CRITICAL MASS): |
| Worst case 1549 pounds U02F2 +/- 50% (max. 2323 pounds) at 2.26% based on |
| available Non-Destructive analysis Measurements. This mass is above the |
| minimum critical mass (690 pounds U02F2 at optimum conditions) for this |
| enrichment level. |
| |
| NUCLEAR CRITICALITY SAFETY CONTROL(S) OR CONTROL SYSTEM(S) AND DESCRIPTION |
| OF THE FAILURES OR DEFICIENCIES: |
| Moderation Control was not maintained for up to 5 months, change in system |
| configuration unknowingly isolated the deposit from pressure monitoring |
| point. |
| |
| CORRECTIVE ACTIONS TO RESTORE SAFETY SYSTEM AND WHEN EACH WAS IMPLEMENTED: |
| 0425 hours required buffer re-established, the valves involved were opened |
| and tagged to remain open, verified remaining 4 like conditions were |
| buffered as required. Investigation in progress. |
| |
| The licensee notified the NRC Resident Inspector and the on-site DOE |
| representative. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 38307 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: WATTS BAR REGION: 2 |NOTIFICATION DATE: 09/23/2001|
| UNIT: [1] [] [] STATE: TN |NOTIFICATION TIME: 18:45[EDT]|
| RXTYPE: [1] W-4-LP,[2] W-4-LP |EVENT DATE: 09/23/2001|
+------------------------------------------------+EVENT TIME: 18:34[EDT]|
| NRC NOTIFIED BY: BEN HUNT |LAST UPDATE DATE: 09/23/2001|
| HQ OPS OFFICER: JOHN MacKINNON +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |BRIAN BONSER R2 |
|10 CFR SECTION: |JOHN ZWOLINSKI NRR |
|NINF INFORMATION ONLY | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| CONDITION FOR AN UNUSUAL EVENT REPORTED BUT NOT DECLARED. |
| |
| |
| At 1755ET the sensing line to the "B" Centrifugal Charging Pump (CCP) local |
| discharge pressure gage broke. The operator noticed that the Volume Control |
| Tank level was decreasing, Reactor Coolant System Pressurizer level did not |
| change, but the VCT low level alarm was never reached. The leak was from |
| the sensing line for "B" CCP local discharge pressure gage which is located |
| in the Auxiliary Building. The leak rate was determined to be approximately |
| 25 gpm by using the plant computer monitor to determine the rate of change |
| of the Volume Control Tank level. All the water issuing from the sensing |
| line drained into the Auxiliary Building drain system which drained into the |
| radwaste system. No release offsite. |
| |
| The licensee is not in any Limiting Condition of Operation at this time. |
| "B" CCP is fully operable because it's discharge pressure can be read from |
| several locations, "A" CCP is fully operable. All other emergency core |
| cooling systems, emergency diesel generators are fully operable if needed. |
| State and Local officials were notified of this event. |
| |
| The time between 1801 hours and 1834 hours were used to determine the size |
| of the leak from the Volume Control Tank. |
| |
| The NRC Resident Inspector will be notified of this event by the licensee. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 38308 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: NINE MILE POINT REGION: 1 |NOTIFICATION DATE: 09/24/2001|
| UNIT: [1] [] [] STATE: NY |NOTIFICATION TIME: 05:55[EDT]|
| RXTYPE: [1] GE-2,[2] GE-5 |EVENT DATE: 09/24/2001|
+------------------------------------------------+EVENT TIME: 04:55[EDT]|
| NRC NOTIFIED BY: LAURIE RAYLE |LAST UPDATE DATE: 09/24/2001|
| HQ OPS OFFICER: FANGIE JONES +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |JAMES LINVILLE R1 |
|10 CFR SECTION: | |
|ACOM 50.72(b)(3)(xiii) LOSS COMM/ASMT/RESPONSE| |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| LOSS OF PROMPT NOTIFICATION TONE ALERT RADIO FOR GREATER THAN 1 HOUR |
| |
| The licensee received a call at 0504 EDT from the Oswego County Warning |
| Point that the Oswego County Prompt Notification Tone Alert Radio had been |
| out-of-service for greater than 1 hour as of 0455 EDT. The cause of the |
| outage is unknown and is being investigated. |
| |
| The licensee notified the NRC Resident Inspector. |
+------------------------------------------------------------------------------+