Event Notification Report for August 17, 2001
U.S. Nuclear Regulatory Commission Operations Center Event Reports For 08/16/2001 - 08/17/2001 ** EVENT NUMBERS ** 38201 38212 38213 38214 38215 38216 38217 38218 38219 !!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED !!!!!!! +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 38201 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: OYSTER CREEK REGION: 1 |NOTIFICATION DATE: 08/10/2001| | UNIT: [1] [] [] STATE: NJ |NOTIFICATION TIME: 23:02[EDT]| | RXTYPE: [1] GE-2 |EVENT DATE: 08/10/2001| +------------------------------------------------+EVENT TIME: 21:15[EDT]| | NRC NOTIFIED BY: ERIC DEMONCH |LAST UPDATE DATE: 08/16/2001| | HQ OPS OFFICER: LEIGH TROCINE +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: NON EMERGENCY |DANIEL HOLODY R1 | |10 CFR SECTION: | | |ARPS 50.72(b)(2)(iv)(B) RPS ACTUATION - CRITICA| | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 84 Power Operation |84 Power Operation | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | UNPLANNED REACTOR PROTECTION SYSTEM (RPS) SYSTEM/SAFETY SYSTEM ACTUATIONS | | WHILE CRITICAL | | | | The following text is a portion of a facsimile received from the licensee: | | | | "[The unit] received [an] isolation of the [transverse incore probe (TIP)] | | purge system and the offgas system during [an] electrical transient on the | | 230kV distribution system. [The licensee believes] the isolations were | | caused by the voltage fluctuations felt in the plant from the grid. Since | | the TIP purge isolation is processed through [the reactor protection system | | (RPS)] and offgas from the offgas [radiation] monitors, this falls under | | actuation of a safety system while critical." | | | | "[The licensee] reset isolations and restored systems to normal." | | | | The licensee stated that the isolation signals that were processed did not | | show up on any alarms. Alarms were received but nothing specific to | | indicate the isolations. This may have been due to voltage | | fluctuations/losses as a result of power/instrument panels that transferred | | to their alternate power supplies. The voltage fluctuations on the in-house | | 4160V buses were attributed to the electrical transient on the 230kV | | distribution system. | | | | There was severe weather in the area at the time of this event. As a | | result, one of two 230kV outgoing power lines and both 34.5kV feed lines | | were lost. All of these lines have since been returned to service. The | | licensee stated that offsite power was never lost because one 230kV line | | remained available to backfeed/supply the 34.5kV buses. | | | | The licensee notified the NRC resident inspector. | | | | * * * RETRACTED AT 1840 EDT ON 8/16/2001 BY JERE FREEMAN TO FANGIE JONES * * | | * | | | | The licensee, after review of the event, determined that the actuation of a | | single component due to a power panel transfer on a voltage transient did | | not meet the requirement of an actuation of the containment isolation system | | for reportability. Per NUREG 1022 Rev 2, this event was not reportable and | | is retracted. | | | | The licensee notified the NRC Resident Inspector. The R1DO (William Ruland) | | has been notified. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Fuel Cycle Facility |Event Number: 38212 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: MALLINCKRODT INC. |NOTIFICATION DATE: 08/16/2001| | RXTYPE: NUCLEAR PHARMACY |NOTIFICATION TIME: 10:00[EDT]| | COMMENTS: RADIOPHARMACEUTICAL OPERATIONS |EVENT DATE: 08/16/2001| | MEDICAL R&D |EVENT TIME: 08:45[CDT]| | |LAST UPDATE DATE: 08/16/2001| | CITY: MARYLAND HTS. REGION: 3 +-----------------------------+ | COUNTY: ST. LOUIS STATE: MO |PERSON ORGANIZATION | |LICENSE#: 24-4206-01 AGREEMENT: N |THOMAS KOZAK R3 | | DOCKET: 03000001 |BRIAN SMITH NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: JAMES SCHUH | | | HQ OPS OFFICER: STEVE SANDIN | | +------------------------------------------------+ | |EMERGENCY CLASS: NON EMERGENCY | | |10 CFR SECTION: | | |BAD1 20.2202(a)(1) PERS OVEREXPOSURE | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | PERSONNEL OVEREXPOSURES INVOLVING TWO WORKERS BETWEEN 1995 AND 1999 | | | | An on-going dose reconstruction in response to Confirmatory Action Letter | | EA-00-143, dated June 22, 2000, identified two (2) workers who received more | | than 250 Rem to their extremities, specifically less than one (1) square | | centimeter of the fingertips. The overexposures occurred between 1995 and | | 1999 on seven (7) occurrences during the manufacturing process involving | | P-32. The licensee will inform the two individuals involved and offer | | medical services, if requested. The licensee discussed this incident with | | NRC Region 3 (Cameron). | | | | * * * UPDATED AT 1532 EDT ON 8/16/2001 BY JAMES SCHUH TO FANGIE JONES * * * | | | | The on-going review has identified a total of 4 workers in 10 occurrences | | with overexposures. All have occurred in similar activities except for 1 | | person in 2 events doing a different process. NRC Region 3 (Bob Gatone) has | | been contacted by the licensee. | | | | The R3DO (Thomas Kozak) and NMSS (Brian Smith) have been notified. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 38213 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: BROWNS FERRY REGION: 2 |NOTIFICATION DATE: 08/16/2001| | UNIT: [] [2] [3] STATE: AL |NOTIFICATION TIME: 11:14[EDT]| | RXTYPE: [1] GE-4,[2] GE-4,[3] GE-4 |EVENT DATE: 08/16/2001| +------------------------------------------------+EVENT TIME: 08:25[CDT]| | NRC NOTIFIED BY: TERRY KNUETTEL |LAST UPDATE DATE: 08/16/2001| | HQ OPS OFFICER: STEVE SANDIN +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: NON EMERGENCY |CHARLIE PAYNE R2 | |10 CFR SECTION: | | |HFIT 26.73 FITNESS FOR DUTY | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | | | |2 N Y 100 Power Operation |100 Power Operation | |3 N Y 100 Power Operation |100 Power Operation | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | FITNESS FOR DUTY REPORT INVOLVING CONTRACTOR FOREMAN | | | | A contractor foreman was determined to be under the influence of alcohol | | during a random test. The contractor's access to the plant has been | | terminated. The licensee informed the NRC Region 2 Office (Wallow) and the | | Resident Inspector. | | | | Contact the Headquarters Operation Officer for details. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 38214 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: LIMERICK REGION: 1 |NOTIFICATION DATE: 08/16/2001| | UNIT: [1] [2] [] STATE: PA |NOTIFICATION TIME: 11:40[EDT]| | RXTYPE: [1] GE-4,[2] GE-4 |EVENT DATE: 08/16/2001| +------------------------------------------------+EVENT TIME: 09:25[EDT]| | NRC NOTIFIED BY: PETER ORPHANOS |LAST UPDATE DATE: 08/16/2001| | HQ OPS OFFICER: FANGIE JONES +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: NON EMERGENCY |RONALD BELLAMY R1 | |10 CFR SECTION: | | |ACOM 50.72(b)(3)(xiii) LOSS COMM/ASMT/RESPONSE| | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 100 Power Operation |100 Power Operation | |2 N Y 100 Power Operation |100 Power Operation | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | ALL EMERGENCY OFFSITE SIRENS INOPERABLE | | | | The licensee determined that all 16 Emergency Offsite Sirens were | | inoperable. The exact cause of the failure is unknown and a plan is being | | developed to repair the sirens. | | | | The licensee notified the NRC Resident Inspector and intends to notify the | | state and local authorities. | | | | * * * UPDATED AT 1735 EDT ON 8/16/2001 BY PETER ORPHANOS TO FANGIE JONES * * | | * | | | | "As of 1300 August 16, 2001 163 of 165 Limerick Generating Station Emergency | | Offsite Sirens are determined to be functional. | | | | "A plan has been developed and investigation continues into the cause of the | | inoperability of the sirens." | | | | The licensee notified the NRC Resident Inspector. The R1DO (William Ruland) | | has been notified. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Fuel Cycle Facility |Event Number: 38215 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: PORTSMOUTH GASEOUS DIFFUSION PLANT |NOTIFICATION DATE: 08/16/2001| | RXTYPE: URANIUM ENRICHMENT FACILITY |NOTIFICATION TIME: 12:23[EDT]| | COMMENTS: 2 DEMOCRACY CENTER |EVENT DATE: 08/15/2001| | 6903 ROCKLEDGE DRIVE |EVENT TIME: 15:45[EDT]| | BETHESDA, MD 20817 (301)564-3200 |LAST UPDATE DATE: 08/16/2001| | CITY: PIKETON REGION: 3 +-----------------------------+ | COUNTY: PIKE STATE: OH |PERSON ORGANIZATION | |LICENSE#: GDP-2 AGREEMENT: N |THOMAS KOZAK R3 | | DOCKET: 0707002 |JOHN HICKEY NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: MIKE RITCHIE | | | HQ OPS OFFICER: FANGIE JONES | | +------------------------------------------------+ | |EMERGENCY CLASS: NON EMERGENCY | | |10 CFR SECTION: | | |NBNL RESPONSE-BULLETIN | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | 24-HOUR NRC BULLETIN 91-01 REPORT | | | | The licensee has notified the NRC Resident Inspector and the DOE | | representative. | | | | The following text is a portion of a facsimile received from Portsmouth | | personnel: | | | | During a walk through of the X-705 Decontamination Facility a hole was | | discovered on the top of the Calciner glove box. The hole could have allowed | | uranium bearing solution to accumulate in the bottom of the glove box [in] | | the unlikely event of a leak. This is in violation of the analysis of | | NCSA-705_024.E02 "Calciner Solution Recovery" which specifically evaluates | | this event. | | | | The PSS entered an anomalous condition. Tape was placed over the hole on the | | top of the Calciner glove box. The PSS exited the anomalous condition. | | | | This event is reportable per NRC BL 91-01 as a loss of one control of the | | double contingency principle. | | | | SAFETY SIGNIFICANCE OF EVENTS: low | | | | There was no leak of uranium bearing material in the vicinity of the | | Calciner glove box. Also, the opening on the glove box is very small. This | | would require a significant amount of time for the solution to accumulate in | | the glove [box] had a leak occurred at that exact location. | | | | POTENTIAL CRITICALITY PATHWAYS INVOLVED (BRIEF SCENARIO[S] OF HOW | | CRITICALITY COULD | | OCCUR): | | | | For a criticality to occur, the following events would be required: The | | recovery system would have to be operating and processing uranium bearing | | liquid with a high concentration of uranium. Then the leak in this system | | must occur such that solution sprays onto the glove box. The liquid would | | then have to flow through the small opening on the top of the glove box and | | accumulate to a depth of >1.5 inches. | | | | CONTROLLED PARAMETERS (MASS, MODERATION, GEOMETRY, CONCENTRATION, ETC.): | | volume, geometry | | | | The unlikely event supporting double contingency credits the integrity of | | the glove box for preventing solution from collecting in an unsafe | | geometry/volume. The hole on the top of the glove box could potentially | | allow solution to enter the glove box. | | | | ESTIMATED AMOUNT, ENRICHMENT, FORM OF LICENSED MATERIAL (INCLUDE PROCESS | | LIMIT AND % WORST CASE OF CRITICAL MASS): | | | | No uranium material was involved in this event. | | | | NUCLEAR CRITICALITY SAFETY CONTROL(S) OR CONTROL SYSTEM(S) AND DESCRIPTION | | OF THE FAILURES OR DEFICIENCIES: | | | | The hole could have allowed uranium bearing solution to accumulate in the | | bottom of the glove box in the unlikely event of a leak. This is in | | violation of the analysis of NCSA-705_024.E02 "Calciner Solution Recovery" | | which specifically evaluates this event. The presence of the opening | | undermines the basis of an unlikely event credited for double contingency. | | | | CORRECTIVE ACTIONS TO RESTORE SAFETY SYSTEM AND WHEN EACH WAS IMPLEMENTED: | | | | Tape was [placed] on the hole on top of the glove box. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 38216 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: OCONEE REGION: 2 |NOTIFICATION DATE: 08/16/2001| | UNIT: [1] [2] [3] STATE: SC |NOTIFICATION TIME: 16:19[EDT]| | RXTYPE: [1] B&W-L-LP,[2] B&W-L-LP,[3] B&W-L-L|EVENT DATE: 08/16/2001| +------------------------------------------------+EVENT TIME: 13:55[EDT]| | NRC NOTIFIED BY: PRESTON GILLESPIE |LAST UPDATE DATE: 08/16/2001| | HQ OPS OFFICER: FANGIE JONES +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: NON EMERGENCY |CHARLIE PAYNE R2 | |10 CFR SECTION: | | |APRE 50.72(b)(2)(xi) OFFSITE NOTIFICATION | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 100 Power Operation |100 Power Operation | |2 N Y 100 Power Operation |100 Power Operation | |3 N Y 100 Power Operation |100 Power Operation | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | OFFSITE NOTIFICATION DUE TO OIL SPILL AT ASSOCIATED HYDRO UNIT | | | | The licensee was performing work on the pier at the Keowee Hydro Intake | | structure when about 1 gallon of Mobil EAL 224H (biodegradable) oil spilled | | into Lake Keowee. A boom had previously been installed and contained the | | oil in a 50 foot by 50 foot area. The spill was a result of a hydraulic | | hose leak. The clean-up was nearly complete at the time of the report. | | There was no effect on plant operations or any safety significance. | | | | The licensee notified the National Response Center, the South Carolina | | Department of Health and Environmental Control, and the NRC Resident | | Inspector. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |General Information or Other |Event Number: 38217 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: COLORADO DEPT OF HEALTH |NOTIFICATION DATE: 08/16/2001| |LICENSEE: CITY AND COUNTY OF DENVER |NOTIFICATION TIME: 19:00[EDT]| | CITY: DENVER REGION: 4 |EVENT DATE: 08/14/2001| | COUNTY: DENVER STATE: CO |EVENT TIME: 13:40[MDT]| |LICENSE#: 333-03 AGREEMENT: Y |LAST UPDATE DATE: 08/16/2001| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |WILLIAM JOHNSON R4 | | |THOMAS ESSIG NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: CLAYTON GOODWIN | | | HQ OPS OFFICER: FANGIE JONES | | +------------------------------------------------+ | |EMERGENCY CLASS: NON EMERGENCY | | |10 CFR SECTION: | | |NAGR AGREEMENT STATE | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | AGREEMENT STATE REPORT - DAMAGED TROXLER GAUGE | | | | "At approximately 1:40 PM on August 14, 2001 an unidentified person in a | | private automobile ran over a Troxler nuclear density gauge while this gauge | | was being used by a trained technician at a work site southwest Denver. The | | technician narrowly escaped being stuck by the vehicle, but the vehicle did | | strike the gauge. The exterior casing of the gauge was damaged and broken | | into numerous pieces as a result of the collision. However the sealed source | | and shielding assembly remained intact. Following the incident the source | | was able to be retracted into the shielding and the shutter closed." | | | | Denver Police were notified immediately following the incident. | | | | The site and the gauge with the sealed source were surveyed and no leakage | | was found. | | | | The Troxler gauge involved is a model 4640B (serial number 841) containing a | | single, 8-millicurie, Cs-137, sealed source (serial number 50-7987). | | | | The gauge will be shipped back to Troxler. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 38218 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: PEACH BOTTOM REGION: 1 |NOTIFICATION DATE: 08/17/2001| | UNIT: [2] [3] [] STATE: PA |NOTIFICATION TIME: 00:31[EDT]| | RXTYPE: [2] GE-4,[3] GE-4 |EVENT DATE: 08/16/2001| +------------------------------------------------+EVENT TIME: 23:25[EDT]| | NRC NOTIFIED BY: STEVE TANNER |LAST UPDATE DATE: 08/17/2001| | HQ OPS OFFICER: STEVE SANDIN +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: NON EMERGENCY |WILLIAM RULAND R1 | |10 CFR SECTION: | | |ACOM 50.72(b)(3)(xiii) LOSS COMM/ASMT/RESPONSE| | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |2 N Y 100 Power Operation |100 Power Operation | |3 N Y 82 Power Operation |82 Power Operation | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | LOSS OF EMERGENCY SIREN REMOTE ACTUATION CAPABILITY | | | | "Omni phone system was lost resulting in a loss of Emergency Siren remote | | actuation control. Power was lost 8/16/01 22:25 EDT and restored 8/16/01 | | 23:55 EDT. Per reportability manual ID# E-02 and Event# SAF 1.10, loss of | | assessment capability is reportable after 8 hours, but loss of greater than | | 25% of the sirens for more than one hour constitutes immediate | | notification. | | | | "The omni phone system was lost due to the associated battery voltage | | becoming too low to support system operation. This was caused by a | | temporary battery charger installed in place of the normal charger (due to a | | failed transformer) not maintaining the battery adequately charged. | | Immediate omni system recovery was effected using available AC power from an | | alternate source to power up the equipment. Long term plans are to replace | | the failed transformer and return the normal charger to service." | | | | The licensee informed the NRC resident inspector and will inform state/local | | agencies. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Other Nuclear Material |Event Number: 38219 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: McMINN'S ASPHALT CO., INC. |NOTIFICATION DATE: 08/17/2001| |LICENSEE: McMINN'S ASPHALT CO., INC. |NOTIFICATION TIME: 04:59[EDT]| | CITY: MANHEIM REGION: 1 |EVENT DATE: 08/17/2001| | COUNTY: STATE: PA |EVENT TIME: 00:30[EDT]| |LICENSE#: 371965901 AGREEMENT: N |LAST UPDATE DATE: 08/17/2001| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |WILLIAM RULAND R1 | | | | +------------------------------------------------+ | | NRC NOTIFIED BY: GARY LUTZ | | | HQ OPS OFFICER: STEVE SANDIN | | +------------------------------------------------+ | |EMERGENCY CLASS: NON EMERGENCY | | |10 CFR SECTION: | | |NINF INFORMATION ONLY | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | TROXLER GAUGE DAMAGED BY VEHICLE AT CONSTRUCTION SITE | | | | At 0030EDT on 8/17/01 a light pickup truck struck a Troxler gauge at a road | | construction project on State Road 340 in Lancaster, PA. The East Lampeter | | Police Department responded (Incident # 01-414) briefly closing traffic. | | The RSO surveyed the device and confirmed that the sealed source was intact | | prior to removal. The Troxler is a model 4640B containing an 8-millicurie | | Cs-137 source. The licensee is returning the device to the manufacturer's | | service center in Timonium, MD for inspection and repair. | +------------------------------------------------------------------------------+
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021