Skip to main content

The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.

Event Notification Report for August 13, 2001

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           08/10/2001 - 08/13/2001

                              ** EVENT NUMBERS **

38196  38197  38198  38199  38200  38201  38202  

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   38196       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  TEXAS DEPARTMENT OF HEALTH           |NOTIFICATION DATE: 08/10/2001|
|LICENSEE:  TERRACON ENGINEERING                 |NOTIFICATION TIME: 09:25[EDT]|
|    CITY:  Dallas                   REGION:  4  |EVENT DATE:        08/09/2001|
|  COUNTY:                            STATE:  TX |EVENT TIME:             [CDT]|
|LICENSE#:  L05268                AGREEMENT:  Y  |LAST UPDATE DATE:  08/10/2001|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |CHARLES MARSCHALL    R4      |
|                                                |FRED BROWN           NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  JAMES H. OGDEN               |                             |
|  HQ OPS OFFICER:  JOHN MacKINNON               |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| STOLEN HUMBOLDT 5001C NUCLEAR GAUGE                                          |
|                                                                              |
|                                                                              |
| The gauge was lost during the hours of darkness July 15-16, 2001, from the   |
| back of a truck that was parked overnight at the home of the driver.  The    |
| gauge and it's transport case were removed from a parked pickup truck by     |
| cutting the chain securing the gauge to the bed of the truck.  Also stolen   |
| during this incident was the operator's toolbox and assorted hand tools.     |
| The gauge is a Humboldt Model 5001C, Serial  # 2606, containing two          |
| radioactive sources: 10 millicuries of cesium-137, Serial #6171GQ; and 40    |
| millicuries of americium-241;Be, Serial # NJ02767.  A police report was      |
| filed on July 16, 2001, with the Dallas Police Department (Report #          |
| 0551265-K).  A press release offering a $250 reward for the return of the    |
| gauge was run in the Dallas Morning News for two days.  The gauge has not    |
| been recovered as of this date.  The licensee has been cited for failure to  |
| maintain the gauge under constant surveillance.  The state of Texas has      |
| informed the Radiation Control authorities in Mexico, Arizona, New Mexico,   |
| Arkansas, and Louisiana, as well as the Humboldt Radiation Safety Officer.   |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38197       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: COOK                     REGION:  3  |NOTIFICATION DATE: 08/10/2001|
|    UNIT:  [] [2] []                 STATE:  MI |NOTIFICATION TIME: 11:21[EDT]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        08/10/2001|
+------------------------------------------------+EVENT TIME:        11:15[EDT]|
| NRC NOTIFIED BY:  LEWIS                        |LAST UPDATE DATE:  08/10/2001|
|  HQ OPS OFFICER:  JOHN MacKINNON               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |ANN MARIE STONE      R3      |
|10 CFR SECTION:                                 |                             |
|ASHU 50.72(b)(2)(i)      PLANT S/D REQD BY TS   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     N          Y       100      Power Operation  |98       Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| TECHNICAL SPECIFICATION SHUTDOWN DUE TO TWO AUXILIARY FEEDWATER PUMPS BEING  |
| INOPERABLE.                                                                  |
|                                                                              |
|                                                                              |
| Commenced Unit 2 plant shutdown to comply with Technical Specification       |
| 3.7.1.2.b: Two Auxiliary Feedwater pumps inoperable.  Unit 2 Turbine Driven  |
| Auxiliary Feedwater pump was inoperable due to scheduled maintenance.  Unit  |
| 2 "2 East" Motor Driven Auxiliary Feedwater pump was declared inoperable due |
| to a failure of associated room cooling (room cooler inoperable) required by |
| administrative procedure PMP 4030.001.001, Impact of Safety Related          |
| Ventilation on the Operability of Technical Specification Equipment.  All    |
| other systems fully are operable.                                            |
|                                                                              |
|                                                                              |
| The NRC Resident Inspector was notified of this event by the licensee.       |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Fuel Cycle Facility                              |Event Number:   38198       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: HONEYWELL INTERNATIONAL, INC.        |NOTIFICATION DATE: 08/10/2001|
|   RXTYPE: URANIUM HEXAFLUORIDE PRODUCTION      |NOTIFICATION TIME: 11:24[EDT]|
| COMMENTS: UF6 CONVERSION (DRY PROCESS)         |EVENT DATE:        08/10/2001|
|                                                |EVENT TIME:        09:45[CDT]|
|                                                |LAST UPDATE DATE:  08/10/2001|
|    CITY:  METROPOLIS               REGION:  3  +-----------------------------+
|  COUNTY:  MASSAC                    STATE:  IL |PERSON          ORGANIZATION |
|LICENSE#:  SUB-526               AGREEMENT:  Y  |ANNE MARIE STONE     R3      |
|  DOCKET:  04003392                             |FRED BROWN           NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  W. LESSIG                    |                             |
|  HQ OPS OFFICER:  BOB STRANSKY                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NONR                     OTHER UNSPEC REQMNT    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| SMALL URANIUM HEXAFLUORIDE RELEASE ONSITE                                    |
|                                                                              |
| The licensee reported that from 0945 to 0950 CDT, a small UF6 release        |
| occurred in the feeds material building. No material left the site, nor did  |
| the licensee declare an Alert. Two individuals were exposed to fumes from    |
| the leak. Those individuals were treated with oxygen at the facility and     |
| transported to a local hospital. The UF6 leak has been stopped.              |
|                                                                              |
| The exact quantity of material released has yet to be determined. The        |
| licensee is currently conducting an investigation of this event.             |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38199       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: MILLSTONE                REGION:  1  |NOTIFICATION DATE: 08/10/2001|
|    UNIT:  [1] [2] [3]               STATE:  CT |NOTIFICATION TIME: 13:18[EDT]|
|   RXTYPE: [1] GE-3,[2] CE,[3] W-4-LP           |EVENT DATE:        08/10/2001|
+------------------------------------------------+EVENT TIME:        10:15[EDT]|
| NRC NOTIFIED BY:  GENE OLSON                   |LAST UPDATE DATE:  08/10/2001|
|  HQ OPS OFFICER:  LEIGH TROCINE                +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |DANIEL HOLODY        R1      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Decommissioned   |0        Decommissioned   |
|2     N          Y       92       Power Operation  |92       Power Operation  |
|3     N          Y       100      Power Operation  |100      Power Operation  |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| PLANNED OFFSITE NOTIFICATION REGARDING A FISH KILL IN THE DISCHARGE QUARRY   |
| DUE TO A RECENT SUSTAINED HEAT WAVE IN THE NORTHEAST                         |
|                                                                              |
| The following text is a portion of a facsimile received from the licensee:   |
|                                                                              |
| "A visual inspection by Millstone [station biologists] on August 10, 2001,   |
| revealed approximately 50 dead [Tautog] (blackfish) in the discharge quarry  |
| by the fish barrier.  A subsequent dive into the quarry by station           |
| biologists [revealed] 2 additional dead Tautog along the fish barrier.  No   |
| additional moralities or other species were found on the bottom of the       |
| quarry."                                                                     |
|                                                                              |
| "The fish most likely died as a result of the sustained elevated             |
| temperatures during the week of August 6, 2001, experienced throughout New   |
| England and Connecticut.  Intake water temperatures have risen above 70      |
| degrees F with discharge temperatures about 98 degree F.  Water temperatures |
| in the quarry have climbed to above 90 degrees F at times during the week.   |
| Tautog are known to have decreased resistant when water temperatures are     |
| above 90 degrees F."                                                         |
|                                                                              |
| "Station [biologists] continue to monitor fish in the quarry."               |
|                                                                              |
| The licensee stated that there was nothing unusual about the temperature     |
| deltas across the condensers and that discharge temperatures are normal.     |
| The licensee also stated that load has been reduced on Unit 2 in order to    |
| keep condenser pressure below the condenser low pressure alarm setpoint and  |
| to maintain discharge temperatures within acceptable limits.  The discharge  |
| temperatures for Unit 3 were reported to be normal with the unit at full     |
| power.                                                                       |
|                                                                              |
| The licensee plans to notify the NRC resident inspector and the State        |
| Department of Environmental Protection.                                      |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38200       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PEACH BOTTOM             REGION:  1  |NOTIFICATION DATE: 08/10/2001|
|    UNIT:  [2] [3] []                STATE:  PA |NOTIFICATION TIME: 19:52[EDT]|
|   RXTYPE: [2] GE-4,[3] GE-4                    |EVENT DATE:        08/10/2001|
+------------------------------------------------+EVENT TIME:        18:10[EDT]|
| NRC NOTIFIED BY:  ROSS MOONITZ                 |LAST UPDATE DATE:  08/10/2001|
|  HQ OPS OFFICER:  LEIGH TROCINE                +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |DANIEL HOLODY        R1      |
|10 CFR SECTION:                                 |                             |
|ACOM 50.72(b)(3)(xiii)   LOSS COMM/ASMT/RESPONSE|                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|2     N          Y       100      Power Operation  |100      Power Operation  |
|3     N          Y       84       Power Operation  |84       Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| LOSS OF GREATER THAN 25% OF THE EMERGENCY PREPAREDNESS SIRENS DUE TO POWER   |
| OUTAGES FROM ELECTRICAL STORMS                                               |
|                                                                              |
| The following text is a portion of a facsimile received from the licensee:   |
|                                                                              |
| "[A total of 26 out of] 97 emergency preparedness sirens (>25%) are out of   |
| service due to power outages from electrical storms.  [This includes 20 out  |
| of] 27 in York County, 2 in Herford County, 2 in Lancaster County, 1 in      |
| Cecil County, and 1 in Chester County.  Plans are in progress to restore     |
| power."                                                                      |
|                                                                              |
| The licensee reported that all systems functioned as required and that there |
| was nothing unusual or misunderstood.  The licensee also reported that there |
| was no loss of offsite power.                                                |
|                                                                              |
| The licensee notified the NRC resident inspector.                            |
|                                                                              |
| ***** UPDATE FROM JACK POPIELARSKI TO LEIGH TROCINE RECEIVED AT 2101 ON      |
| 08/10/01 *****                                                               |
|                                                                              |
| The licensee also notified York County.  The NRC operations officer notified |
| the R1DO (Holody).                                                           |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38201       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: OYSTER CREEK             REGION:  1  |NOTIFICATION DATE: 08/10/2001|
|    UNIT:  [1] [] []                 STATE:  NJ |NOTIFICATION TIME: 23:02[EDT]|
|   RXTYPE: [1] GE-2                             |EVENT DATE:        08/10/2001|
+------------------------------------------------+EVENT TIME:        21:15[EDT]|
| NRC NOTIFIED BY:  ERIC DEMONCH                 |LAST UPDATE DATE:  08/10/2001|
|  HQ OPS OFFICER:  LEIGH TROCINE                +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |DANIEL HOLODY        R1      |
|10 CFR SECTION:                                 |                             |
|ARPS 50.72(b)(2)(iv)(B)  RPS ACTUATION - CRITICA|                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       84       Power Operation  |84       Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| UNPLANNED REACTOR PROTECTION SYSTEM (RPS) SYSTEM/SAFETY SYSTEM ACTUATIONS    |
| WHILE CRITICAL                                                               |
|                                                                              |
| The following text is a portion of a facsimile received from the licensee:   |
|                                                                              |
| "[The unit] received [an] isolation of the [transverse incore probe (TIP)]   |
| purge system and the offgas system during [an] electrical transient on the   |
| 230kV distribution system.  [The licensee believes] the isolations were      |
| caused by the voltage fluctuations felt in the plant from the grid.  Since   |
| the TIP purge isolation is processed through [the reactor protection system  |
| (RPS)] and offgas from the offgas [radiation] monitors, this falls under     |
| actuation of a safety system while critical."                                |
|                                                                              |
| "[The licensee] reset isolations and restored systems to normal."            |
|                                                                              |
| The licensee stated that the isolation signals that were processed did not   |
| show up on any alarms.  Alarms were received but nothing specific to         |
| indicate the isolations.  This may have been due to voltage                  |
| fluctuations/losses as a result of power/instrument panels that transferred  |
| to their alternate power supplies.  The voltage fluctuations on the in-house |
| 4160V buses were attributed to the electrical transient on the 230kV         |
| distribution system.                                                         |
|                                                                              |
| There was severe weather in the area at the time of this event.  As a        |
| result, one of two 230kV outgoing power lines and both 34.5kV feed lines     |
| were lost.  All of these lines have since been returned to service.  The     |
| licensee stated that offsite power was never lost because one 230kV line     |
| remained available to backfeed/supply the 34.5kV buses.                      |
|                                                                              |
| The licensee notified the NRC resident inspector.                            |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38202       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: DUANE ARNOLD             REGION:  3  |NOTIFICATION DATE: 08/12/2001|
|    UNIT:  [1] [] []                 STATE:  IA |NOTIFICATION TIME: 12:16[EDT]|
|   RXTYPE: [1] GE-4                             |EVENT DATE:        08/12/2001|
+------------------------------------------------+EVENT TIME:        07:46[CDT]|
| NRC NOTIFIED BY:  DEAN CURTLAND                |LAST UPDATE DATE:  08/12/2001|
|  HQ OPS OFFICER:  LEIGH TROCINE                +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |ANNE MARIE STONE     R3      |
|10 CFR SECTION:                                 |                             |
|ARPS 50.72(b)(2)(iv)(B)  RPS ACTUATION - CRITICA|                             |
|AESF 50.72(b)(3)(iv)(A)  VALID SPECIF SYS ACTUAT|                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     M/R        Y       100      Power Operation  |0        Hot Shutdown     |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| MANUAL REACTOR SCRAM DUE TO DECREASING REACTOR WATER LEVEL AND GROUP 1       |
| ISOLATION DUE TO LOW REACTOR PRESSURE WHILE IN RUN                           |
|                                                                              |
| The following text is a portion of a facsimile received from the licensee:   |
|                                                                              |
| "At 07:46:00 [CDT], a reactor water low-level alarm was received.  The       |
| reactor operator verified the low-level condition and took manual control of |
| feedwater level control.  The operator matched feedwater and steam flow.  At |
| 07:46:28 [CDT], the 'B' feedwater pump tripped on low suction pressure.  A   |
| manual scram was inserted at 07:46:42 [CDT] due to lowering reactor water    |
| level.  Level dropped below 170 [inches] on the reactor scram [as expected], |
| and [Group 2, 3, and 4 isolations] were received.  All isolations went to    |
| completion.  At 07:47:48 [CDT], a Group 1 isolation was received on the 850  |
| psig low reactor pressure in Run isolation signal.  The operator was in the  |
| process of [taking] the mode switch [out of] Run, but the isolation occurred |
| before this action could be completed.  All [main steam isolation valves]    |
| closed on the Group 1 isolation signal.  Reactor level increased to the high |
| level trip following the reactor scram, as expected, and the 'A' feedwater   |
| pump tripped.  Due to the Group 1 isolation, the operating crew elected to   |
| manually initiate Low Low Set pressure control using the safety relief       |
| valves.  A relief valve was opened, arming Low Low Set, and the two valves   |
| lowered reactor pressure to 900 psig.  The Group 1 was reset, and main steam |
| line drains to the condenser are being used to control pressure.  The 'A'    |
| feedwater pump high level trip has been reset and is maintaining level."     |
|                                                                              |
| "All systems responded as expected.  The plant is currently in Hot Shutdown  |
| at 800 psig.  Plans are being reviewed to determine the length of the forced |
| outage.  Preliminary investigations indicate that the 'B' feedwater pump     |
| minimum flow valve may have failed open to initiate the event."              |
|                                                                              |
| The licensee stated that there were no maintenance or surveillance           |
| activities ongoing at the time of the event.  All control rods fully         |
| inserted following the manual reactor scram.  All containment parameters are |
| currently normal, and offsite power is available.                            |
|                                                                              |
| The licensee notified the NRC resident inspector.                            |
+------------------------------------------------------------------------------+


Page Last Reviewed/Updated Thursday, March 25, 2021

Page Last Reviewed/Updated Thursday, March 25, 2021