The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.
Event Notification Report for August 6, 2001
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
08/03/2001 - 08/06/2001
** EVENT NUMBERS **
38184 38185 38186 38187
+------------------------------------------------------------------------------+
|Fuel Cycle Facility |Event Number: 38184 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PORTSMOUTH GASEOUS DIFFUSION PLANT |NOTIFICATION DATE: 08/03/2001|
| RXTYPE: URANIUM ENRICHMENT FACILITY |NOTIFICATION TIME: 20:33[EDT]|
| COMMENTS: 2 DEMOCRACY CENTER |EVENT DATE: 08/03/2001|
| 6903 ROCKLEDGE DRIVE |EVENT TIME: 16:42[EDT]|
| BETHESDA, MD 20817 (301)564-3200 |LAST UPDATE DATE: 08/03/2001|
| CITY: PIKETON REGION: 3 +-----------------------------+
| COUNTY: PIKE STATE: OH |PERSON ORGANIZATION |
|LICENSE#: GDP-2 AGREEMENT: N |JOHN MADERA R3 |
| DOCKET: 0707002 | |
+------------------------------------------------+ |
| NRC NOTIFIED BY: RON CRABTREE | |
| HQ OPS OFFICER: STEVE SANDIN | |
+------------------------------------------------+ |
|EMERGENCY CLASS: NON EMERGENCY | |
|10 CFR SECTION: | |
|NONR OTHER UNSPEC REQMNT | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| 4-HOUR REPORT INVOLVING NOTIFICATION TO OTHER GOVERNMENT AGENCIES |
| |
| "On 8/3/01 at 1642 the Plant Shift Superintendent received a 911 emergency |
| response notification of a vehicle accident on perimeter road, which is |
| included in the Department Of Energy (DOE) reservation. There was one (1) |
| fatality and three (3) injuries which required hospitalization. |
| Notifications of the vehicle accident were made to Pike County (Ohio) |
| Sheriff's Office. Once it was determined that the accident involved a |
| fatality DOE-OROC, and DOE-HQ were also notified. |
| |
| "This PORTS notification to 'other government agencies' requires |
| notification to the NRC as a 4-hour NRC Event Report." |
| |
| The NRC resident inspector was informed of this report. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 38185 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PRAIRIE ISLAND REGION: 3 |NOTIFICATION DATE: 08/03/2001|
| UNIT: [1] [] [] STATE: MN |NOTIFICATION TIME: 22:56[EDT]|
| RXTYPE: [1] W-2-LP,[2] W-2-LP |EVENT DATE: 08/03/2001|
+------------------------------------------------+EVENT TIME: 20:40[CDT]|
| NRC NOTIFIED BY: JOEL SORENSEN |LAST UPDATE DATE: 08/04/2001|
| HQ OPS OFFICER: STEVE SANDIN +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: UNUSUAL EVENT |JOHN MADERA R3 |
|10 CFR SECTION: |HERB BERKOW NRR |
|AAEC 50.72(a) (1) (i) EMERGENCY DECLARED |JOSEPH HOLONICH IRO |
|ARPS 50.72(b)(2)(iv)(B) RPS ACTUATION - CRITICA|JIM DYER RA |
|AESF 50.72(b)(3)(iv)(A) VALID SPECIF SYS ACTUAT|JON JOHNSON NRR |
|DDDD 73.71 UNSPECIFIED PARAGRAPH |ZAPATA FEMA |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 A/R Y 20 Power Operation |0 Hot Standby |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| UNIT 1 DECLARED AN UNUSUAL EVENT DUE TO A FIRE LASTING GREATER THAN 10 |
| MINUTES |
| |
| A fire occurred in the 4KV Bus 12 while realigning the electrical power |
| supplies from the 1 Reserve Transformer to the 1 Main Transformer during |
| power ascension. Bus 12 supplies both the 12 Reactor Coolant Pump and the |
| 12 Feedwater Pump which were secured. The 11 Reactor Coolant Pump was also |
| secured placing the unit in natural circulation. Auxiliary Feedwater Pumps |
| 11 and 12 are in service (autostarted on lo-lo SG level) supplying both |
| Steam Generators (SG) as normal for a reactor trip. The Main Condenser is |
| in-service for decay heat removal. |
| |
| The licensee is in the process of electrically isolating Bus 12. The Red |
| Wing Fire Department is onsite responding to the fire which has not been |
| confirmed extinguished at the time of this report. |
| |
| The cause of the reactor trip and the fire is unknown. |
| |
| The licensee informed state/local agencies and the NRC resident inspector. |
| |
| * * * UPDATED AT 0016 EDT ON 8/4/2001 BY SCOTT WHITSON TO FANGIE JONES * * |
| * |
| |
| The licensee reported that 2 employees were treated for heat exhaustion on |
| site and another employee was transported to a local hospital at 2255 CDT |
| for the same reason. All were part of the onsite fire brigade. |
| |
| * * * UPDATED AT 0115 EDT ON 8/4/2001 BY DENNIS CARLSON TO FANGIE JONES * * |
| * |
| |
| The licensee exited the Unusual Event at 0012 CDT on 8/4/2001. The plant is |
| stable in natural circulation and all safeguards buses are energized by |
| offsite power. The licensee notified the NRC Resident Inspector. |
| |
| The R3DO (John Madera), NRR EO (Herb Berkow), and FEMA (Zapata) have been |
| notified. |
| |
| * * * UPDATED AT 0325 EDT ON 8/4/2001 BY MIKE SLEIGH TO FANGIE JONES * * * |
| |
| The licensee reported that at the beginning of the Unusual Event a |
| safeguards degradation related to the area boundary took place. |
| Compensatory measures were taken upon discovery. |
| |
| The licensee notified the NRC Resident Inspector and intends to notify R3 |
| IAT (James Creed). The R3DO (John Madera) was notified. |
| |
| Refer to the HOO Log for details. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 38186 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: DIABLO CANYON REGION: 4 |NOTIFICATION DATE: 08/04/2001|
| UNIT: [1] [2] [] STATE: CA |NOTIFICATION TIME: 19:55[EDT]|
| RXTYPE: [1] W-4-LP,[2] W-4-LP |EVENT DATE: 08/04/2001|
+------------------------------------------------+EVENT TIME: 15:22[PDT]|
| NRC NOTIFIED BY: DAVID BAHNER |LAST UPDATE DATE: 08/04/2001|
| HQ OPS OFFICER: STEVE SANDIN +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |CHUCK CAIN R4 |
|10 CFR SECTION: |HERB BERKOW NRR |
|AESF 50.72(b)(3)(iv)(A) VALID SPECIF SYS ACTUAT| |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
|2 N Y 100 Power Operation |100 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| AUTOMATIC START OF BOTH UNITS DIESEL GENERATORS DUE TO A LOSS OF START-UP |
| POWER |
| |
| "Electrical fault caused loss of Start-up Power to both units. This caused |
| all six [6] diesel generators on both units to automatically start." |
| |
| Circuit breaker CB212 which supplies 230KV start-up power to both units |
| opened due to an unidentified electrical fault. Initial indication was a |
| loss of power to outbuildings onsite followed about twenty-two (22) minutes |
| later with a loss of power to the Start-up transformers. Investigation |
| found the grounding fuses on the Unit 1 side open. Should a unit trip occur |
| while in this condition, RCS cooldown by natural circulation would be |
| required. |
| |
| Both units are in Tech Spec LCO 3.8.1 Condition 'A' which requires |
| restoration of start-up power within 72-hours or unit shutdown; mode 3 (hot |
| standby) in the following 6-hours followed by mode 5 (cold shutdown) |
| 36-hours later. The licensee is performing a maintenance and engineering |
| evaluation to determine if start-up can be restored by closing a cross-tie |
| breaker from Unit 2. |
| |
| None of the diesel generators loaded and all have been secured and returned |
| to standby. |
| |
| The licensee informed the NRC resident inspector. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 38187 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: HATCH REGION: 2 |NOTIFICATION DATE: 08/05/2001|
| UNIT: [1] [2] [] STATE: GA |NOTIFICATION TIME: 22:25[EDT]|
| RXTYPE: [1] GE-4,[2] GE-4 |EVENT DATE: 08/05/2001|
+------------------------------------------------+EVENT TIME: 21:30[EDT]|
| NRC NOTIFIED BY: ALAN WOLFE |LAST UPDATE DATE: 08/05/2001|
| HQ OPS OFFICER: BOB STRANSKY +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |KERRY LANDIS R2 |
|10 CFR SECTION: | |
|ACOM 50.72(b)(3)(xiii) LOSS COMM/ASMT/RESPONSE| |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
|2 N Y 100 Power Operation |100 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| NOAA WEATHER RADIO SYSTEM INOPERABLE |
| |
| The NOAA weather radio system was determined to be inoperable at 2130 EDT. |
| The radio system is used as part of the licensee's prompt notification |
| system. The licensee has contacted state and local government agencies. |
| |
| The NRC resident inspector will be informed of this notification by the |
| licensee. |
+------------------------------------------------------------------------------+
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021