The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.
Event Notification Report for June 19, 2001
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
06/18/2001 - 06/19/2001
** EVENT NUMBERS **
38072 38075 38076 38077 38078
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 38072 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: ARKANSAS DEPARTMENT OF HEALTH |NOTIFICATION DATE: 06/14/2001|
|LICENSEE: R. D. PLANT CONTRACTING |NOTIFICATION TIME: 16:09[EDT]|
| CITY: MURFREESBORO REGION: 4 |EVENT DATE: 06/14/2001|
| COUNTY: STATE: AR |EVENT TIME: 10:00[CDT]|
|LICENSE#: ARK756BP0405 AGREEMENT: Y |LAST UPDATE DATE: 06/18/2001|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |JOHN PELLET R4 |
| |JOHN HICKEY NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: DAVID SNELLINGS | |
| HQ OPS OFFICER: FANGIE JONES | |
+------------------------------------------------+ |
|EMERGENCY CLASS: NON EMERGENCY | |
|10 CFR SECTION: | |
|NAGR AGREEMENT STATE | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT - MISSING TROXLER SURFACE DENSITY GAUGE |
| |
| The licensee notified the State of Arkansas about 10:00 AM CDT today |
| 6/14/01, that a Troxler Model 4640B surface density gauge, containing 8 mCi |
| of Cs-137, was missing from the back of his truck. The gauge was known to |
| be chained and locked in the back of the truck last night (6/13/01) around |
| 7:00 PM CDT. The chain and lock are still in the truck, undamaged. The |
| Howard County Sheriff's Department and Hope Arkansas Police have been |
| notified of the missing gauge. There will be a press release sent to state |
| police, surrounding states and local authorities. NRC Region 4 (Vivian |
| Campbell) has been notified. |
| |
| |
| * * * UPDATE ON 6/18/01 @1514 BY BRADLEY TO GOULD * * * |
| |
| The licensee reported to the State (6/18/01 @ 0740) that the gauge had been |
| returned early this morning intact and not damaged. |
| |
| The Reg 4 RDO(Loveless) and the NMSS EO(Fred Brown) |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 38075 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PRAIRIE ISLAND REGION: 3 |NOTIFICATION DATE: 06/18/2001|
| UNIT: [1] [] [] STATE: MN |NOTIFICATION TIME: 10:13[EDT]|
| RXTYPE: [1] W-2-LP,[2] W-2-LP |EVENT DATE: 06/18/2001|
+------------------------------------------------+EVENT TIME: 02:04[CDT]|
| NRC NOTIFIED BY: TODD STRAIN |LAST UPDATE DATE: 06/18/2001|
| HQ OPS OFFICER: FANGIE JONES +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |ROGER LANKSBURY R3 |
|10 CFR SECTION: | |
|AESF 50.72(b)(3)(iv)(A) VALID SPECIF SYS ACTUAT| |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| VITAL BUS SOURCE SEQUENCER ACTIVATED ON LOSS OF NORMAL POWER SUPPLY |
| |
| "This is a notification of an unplanned automatic actuation of the Unit 1 |
| 4.16 kV Sfgds Bus 16 (B-train) source sequencer. Severe weather resulted in |
| an electrical grid disturbance which caused 4.16 kV Bkr CT11-1 to open, |
| subsequently rendering the normal Bus 16 offsite 4.16 kV source (CT11) from |
| 345 kV Bus 1 to Unit 1 to be lost. CT11 transformer is a 13.8 to 4.16 kV |
| step-down transformer. Nothing appears to be wrong with the CT11 |
| transformer. The sequencer operated as designed and transferred Bus 16 to |
| its backup 4.16 kV offsite source (1R). |
| |
| "Charging and letdown were lost during this transient, and subsequently |
| restored. Two (2) of the 4 Cooling Tower Pumps and associated Cooling Towers |
| were also lost and remain out of service. B train Sfgds Control Room |
| ventilation was also lost during the transient. This resulted in a temporary |
| dual unit 7 day LCO entry per TS 3.13.A.2, which was subsequently exited |
| when the operability of the ventilation system was restored. |
| |
| "The plant is currently in a Unit 1 7 day LCO per TS 3.7.B2., and |
| investigating the cause of Bkr CT11-1 opening." |
| |
| The licensee notified the NRC Resident Inspector. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 38076 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: ILLINOIS DEPT OF NUCLEAR SAFETY |NOTIFICATION DATE: 06/18/2001|
|LICENSEE: EVANSTON NORTHWESTERN HOSPITAL |NOTIFICATION TIME: 11:37[EDT]|
| CITY: CHICAGO REGION: 3 |EVENT DATE: 06/14/2001|
| COUNTY: STATE: IL |EVENT TIME: 11:30[CDT]|
|LICENSE#: IL1248-02 AGREEMENT: Y |LAST UPDATE DATE: 06/18/2001|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |MONTE PHILLIPS R3 |
| |JOHN HICKEY NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: MCCANDLESS | |
| HQ OPS OFFICER: CHAUNCEY GOULD | |
+------------------------------------------------+ |
|EMERGENCY CLASS: NON EMERGENCY | |
|10 CFR SECTION: | |
|NAGR AGREEMENT STATE | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| ILLINOIS LICENSEE REPORTED TO THE STATE THAT THEY HAD A MEDICAL |
| MISADMINISTRATION |
| |
| The Evanston Northwestern Hospital reported that they had a medical |
| misadministration(while performing an IVB event) when they were unprepared |
| with the second syringe after the primary syringe ran out of water. This |
| resulted in an increase in treatment time by 23% (prescribed treatment time |
| was 206 mins and actual time was 253.4mins). The isotope used was Sr-90 |
| with an activity of 1.2 GBq. |
| |
| The following fax was received after the initial telephone report: |
| |
| "[Northwestern Hospital] called [the Illinois Department of Nuclear Safety] |
| at 11:33 to report that they had an IVB event this morning using the Novoste |
| device. Apparently they ran out of water in the primary syringe and were not |
| prepared with a secondary syringe to replace it. This caused an increase in |
| the treatment time by 23%. The prescribed treatment time was 3 minutes and |
| 26 seconds. [Northwestern Hospital] was unclear if the sources moved during |
| the syringe change-out procedure. He is not on-site but he will call with |
| additional details once he returns to the hospital. The isotope involved is |
| Sr-90 with an activity of 1.2 GBq." |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 38077 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PEACH BOTTOM REGION: 1 |NOTIFICATION DATE: 06/18/2001|
| UNIT: [2] [3] [] STATE: PA |NOTIFICATION TIME: 11:39[EDT]|
| RXTYPE: [2] GE-4,[3] GE-4 |EVENT DATE: 06/18/2001|
+------------------------------------------------+EVENT TIME: 03:15[EDT]|
| NRC NOTIFIED BY: CHRIS COSTANSO |LAST UPDATE DATE: 06/18/2001|
| HQ OPS OFFICER: FANGIE JONES +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |JAMES TRAPP R1 |
|10 CFR SECTION: | |
|AIND 50.72(b)(3)(v)(D) ACCIDENT MITIGATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|2 N Y 100 Power Operation |100 Power Operation |
|3 N Y 100 Power Operation |100 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| BREAKER CONTROL SWITCHES NOT PROPERLY ALIGNED |
| |
| "This report is being made under the reporting requirement in |
| 10CFR50.72(b)(3)(vi) to describe an event or condition that could have |
| prevented the fulfillment of a safety function. |
| |
| "On June 18. 2001, at approximately 0315, an offsite power supply to two of |
| four emergency buses on both Units 2 and 3 was lost. All four emergency |
| buses automatically transferred to their respective alternate supply per |
| design |
| |
| "The restoration procedure subsequently directed the crew to 'green flag' |
| the tripped breakers. The purpose of the procedural step was to align the |
| breaker switch with the actual position of the breaker. The procedure, |
| however, did not direct the crew to 'red flag' the alternate breakers which |
| automatically closed (i.e. match the switch position to the actual breaker |
| position). This created a condition in the electrical logic which would have |
| prevented two of four emergency buses from automatically receiving power |
| from their respective diesel generators in the event of a design basis |
| accident. |
| |
| "Once discovered, the crew 'red flagged' the alternate breakers and restored |
| diesel generator operability. |
| |
| "The restoration procedures have been revised to prevent this condition from |
| reoccurring. |
| |
| "The NRC resident has been informed." |
| |
| The condition existed for about 3 hours, at which time the breaker switches |
| were placed in the 'red flagged' position as required. An investigation is |
| ongoing to determine the cause of the initial power loss. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 38078 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SALEM REGION: 1 |NOTIFICATION DATE: 06/18/2001|
| UNIT: [] [2] [] STATE: NJ |NOTIFICATION TIME: 14:44[EDT]|
| RXTYPE: [1] W-4-LP,[2] W-4-LP |EVENT DATE: 06/18/2001|
+------------------------------------------------+EVENT TIME: 14:10[EDT]|
| NRC NOTIFIED BY: MCKUNE |LAST UPDATE DATE: 06/18/2001|
| HQ OPS OFFICER: CHAUNCEY GOULD +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: UNUSUAL EVENT |JAMES TRAPP R1 |
|10 CFR SECTION: |RICHARD WESSMAN IRO |
|AAEC 50.72(a) (1) (i) EMERGENCY DECLARED |TAD MARSH EO |
| |EACHES FEMA |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
| | |
|2 N Y 100 Power Operation |100 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| PLANT DECLARED AN UNUSUAL EVENT DUE TO A TOXIC FUME RELEASE LIMITING ACCESS |
| TO THE AREA |
| |
| During chemical unloading of sulfuric acid from a truck trailer, excessive |
| acid fumes came from the tank, which was located in the turbine building. |
| The chemistry technician supporting the delivery experienced throat and |
| respiratory irritation and was transported to the hospital for examination. |
| The delivery was stopped at the time of discovery and access to the area has |
| been limited. An investigation as to the cause is in progress. The |
| licensee will notify the NRC Resident Inspector and has notified the New |
| Jersey, Delaware and Lower Alloways Creek Township Police Departments. |
| |
| * * * UPDATE ON 6/18/01 @ 1832 BY MCGREGER TO GOULD * * * |
| |
| The NOUE was terminated at 1828 since there no longer is any leakage being |
| detected. They believe the leak was from a vent path, since no breech was |
| detected. |
| |
| The NRC Resident Inspector will be notified. |
| |
| The Reg 1 RDO(Trap), EO(Matthews) and FEMA(Belcher) were notified. |
+------------------------------------------------------------------------------+
Page Last Reviewed/Updated Thursday, March 25, 2021