Skip to main content

The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.

Event Notification Report for June 12, 2001

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           06/11/2001 - 06/12/2001

                              ** EVENT NUMBERS **

38061  38062  38063  38064  38065  

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38061       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: BYRON                    REGION:  3  |NOTIFICATION DATE: 06/11/2001|
|    UNIT:  [] [2] []                 STATE:  IL |NOTIFICATION TIME: 11:44[EDT]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        04/19/2001|
+------------------------------------------------+EVENT TIME:        23:00[CDT]|
| NRC NOTIFIED BY:  MARRI MARCHIONOA             |LAST UPDATE DATE:  06/11/2001|
|  HQ OPS OFFICER:  DOUG WEAVER                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |ROGER LANKSBURY      R3      |
|10 CFR SECTION:                                 |                             |
|AINV 50.73(a)(1)         INVALID SPECIF SYSTEM A|                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     N          N       0        Cold Shutdown    |0        Cold Shutdown    |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| 60 DAY REPORT - INVALID ACTUATION OF THE AUXILIARY FEEDWATER SYSTEM          |
|                                                                              |
| "On April 19. 2001, at 2300, during restoration of an out of service which   |
| required relanding two leads at Solid State Protection System slave relay    |
| K620, one wire came off the screw as it was being relanded to slave relay    |
| K620 and made intermittent contact with terminal 8.  It was subsequently     |
| found the Unit 2 'A' Auxiliary Feedwater pump breaker closed but the pump    |
| did not start since the breaker was in the test position and steam generator |
| blowdown containment isolation valve 2SD002H was closed.  The Unit 2 'A'     |
| Auxiliary Feedwater pump and 2SD002H are both actuated by slave relay K633   |
| which is fed from the same master relay that feeds slave relay K620.  It     |
| could not be determined how slave relay K633 was actuated during this        |
| evolution. This is considered a partial train actuation.  Other slave relay  |
| components were properly removed from service or in a position such that     |
| their safety function had already been completed or were not expected to     |
| actuate due to the short duration of the signal.  Subsequent slave relay     |
| testing verified all slave relays and equipment circuits were operating      |
| properly.  The event was entered into the Corrective Action Process to       |
| initiate corrective actions."                                                |
|                                                                              |
| The NRC Resident Inspector was notified of this 60 day report by the         |
| licensee.                                                                    |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38062       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: MILLSTONE                REGION:  1  |NOTIFICATION DATE: 06/11/2001|
|    UNIT:  [] [] [3]                 STATE:  CT |NOTIFICATION TIME: 12:34[EDT]|
|   RXTYPE: [1] GE-3,[2] CE,[3] W-4-LP           |EVENT DATE:        06/11/2001|
+------------------------------------------------+EVENT TIME:        11:26[EDT]|
| NRC NOTIFIED BY:  ROBERT SMITH                 |LAST UPDATE DATE:  06/11/2001|
|  HQ OPS OFFICER:  DOUG WEAVER                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |ANIELLO DELLA GRECA  R1      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|                                                   |                          |
|3     N          Y       100      Power Operation  |100      Power Operation  |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| FIRE IN AN OFFSITE SUBSTATION - LOCAL FIRE DEPARTMENT CALLED                 |
|                                                                              |
| The licensee requested offsite assistance from the Goshen Fire Department    |
| because of a fire outside the protected area.  The fire is in a substation   |
| near the fire training facility and has affected power to the Emergency      |
| Operations Facility (EOF). The EOF has an emergency diesel generator, but    |
| this tripped when it was brought on line.   Plant operations are not         |
| affected.                                                                    |
|                                                                              |
| The fire department is on scene and has not identified any flames, but smoke |
| is still coming from the substation, the substation is partially             |
| underground.  The licensee will notify the town of Waterford and the State   |
| of Connecticut.  The NRC resident has been notified.                         |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Fuel Cycle Facility                              |Event Number:   38063       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PORTSMOUTH GASEOUS DIFFUSION PLANT   |NOTIFICATION DATE: 06/11/2001|
|   RXTYPE: URANIUM ENRICHMENT FACILITY          |NOTIFICATION TIME: 14:04[EDT]|
| COMMENTS: 2 DEMOCRACY CENTER                   |EVENT DATE:        06/11/2001|
|           6903 ROCKLEDGE DRIVE                 |EVENT TIME:        13:23[EDT]|
|           BETHESDA, MD 20817    (301)564-3200  |LAST UPDATE DATE:  06/11/2001|
|    CITY:  PIKETON                  REGION:  3  +-----------------------------+
|  COUNTY:  PIKE                      STATE:  OH |PERSON          ORGANIZATION |
|LICENSE#:  GDP-2                 AGREEMENT:  N  |ROGER LANKSBURY      R3      |
|  DOCKET:  0707002                              |FREDERICK BROWN      NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  GARY SALYERS                 |                             |
|  HQ OPS OFFICER:  BOB STRANSKY                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|NONR                     OTHER UNSPEC REQMNT    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION                                                         |
|                                                                              |
| "At 1323 hrs, the Ohio Environmental Protection Agency (OEPA) was notified   |
| per Ohio Administrative Code (OAC) 3745-15-06(B) that an opacity exceedance  |
| had occurred at the X-600 Steam Plant. Details are provided below.           |
|                                                                              |
| "At approximately 0500 hrs, Utilities Operations personnel began shutting    |
| off the steam flow to the X-333 Process Building in preparation for          |
| maintenance and repair work on the steam lines. Total steam demand dropped   |
| to approximately 92,000 lb/hr (46,000 lb/hr for each of the two operating    |
| boilers). The boilers are difficult to control below approximately 50,000    |
| lb/hr. At approximately 0518 (based on six-minute increments), Boiler #1     |
| reached an opacity of 23% for 6 minutes, then dropped below 20%. At 0530, it |
| rose to 33% for 6 minutes. At 0542, it again rose to 33% for 6 minutes. At   |
| 0600, it rose initially to 23%, then to approximately 28%. The Boiler        |
| Operators started several steam turbines to increase the load above 50,000   |
| lb/hr each and regained control.                                             |
|                                                                              |
| "OAC 3745-17-07 limits the boilers to an opacity of 20% as a 6 minute        |
| average. One 6 minute average per 60 minute period may exceed 20% but may    |
| not exceed 60%. There were four six-minute readings between 20% and 60% in a |
| 60 minute period, therefore, this is reportable to the Ohio EPA. OAC         |
| 3745-15-06(B) requires an immediate report in the event that a malfunction   |
| causes the emission of contaminants in violation of any applicable law. By   |
| reporting such an incident in a timely manner, the incident is not           |
| considered a violation. Details of the incident will be included in the next |
| quarterly OEPA opacity report. Site management has taken action to prevent   |
| recurrence of any further opacity exceedances related to the above mentioned |
| maintenance evolution.                                                       |
|                                                                              |
| "This is reportable as a 4 hr. Event due to notification to a government     |
| agency (OEPA) being made per Nuclear Regulatory Event Reporting Procedure    |
| UE2-RA-RE1030 Appendix D Criteria P. (Miscellaneous)."                       |
|                                                                              |
| The NRC resident inspector has been informed of this notification.           |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Other Nuclear Material                           |Event Number:   38064       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  ION BEAM APPLICATIONS                |NOTIFICATION DATE: 06/11/2001|
|LICENSEE:  ION BEAM APPLICATIONS                |NOTIFICATION TIME: 15:48[EDT]|
|    CITY:  ROCKAWAY                 REGION:  1  |EVENT DATE:        06/11/2001|
|  COUNTY:                            STATE:  NJ |EVENT TIME:        12:25[EDT]|
|LICENSE#:  29-3030801            AGREEMENT:  N  |LAST UPDATE DATE:  06/11/2001|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |ANIELLO DELLA GRECA  R1      |
|                                                |FREDERICK BROWN      NMSS    |
+------------------------------------------------+JOSEPH HOLONICH      IRO     |
| NRC NOTIFIED BY:  STAN YAP                     |                             |
|  HQ OPS OFFICER:  DOUG WEAVER                  |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          NON EMERGENCY         |                             |
|10 CFR SECTION:                                 |                             |
|MAAA 36.83(a)(1)         UNSHIELD STUCK SOURCE  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| IRRADIATOR SOURCE RACK STUCK IN THE UNSHIELDED POSITION                      |
|                                                                              |
| While initiating a run, one of two source racks did not fully withdrawal.    |
| The system is designed to automatically lower the racks if the full out      |
| position is not reached within a set amount of time.  This occurred, but the |
| same rack that did not fully withdrawal would not insert.  The licensee      |
| noted the occurrence and attempted to raise the stuck rack a little, hoping  |
| to free it.   This worked and then the rack was fully inserted without       |
| incident.                                                                    |
|                                                                              |
| Upon investigation it was discovered that there was a loose guide cable.     |
| This cable was tensioned and the rack was tested several times with no       |
| problems.   The irradiator was then returned to service.                     |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   38065       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: CATAWBA                  REGION:  2  |NOTIFICATION DATE: 06/11/2001|
|    UNIT:  [1] [2] []                STATE:  SC |NOTIFICATION TIME: 16:50[EDT]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        06/11/2001|
+------------------------------------------------+EVENT TIME:        14:00[EDT]|
| NRC NOTIFIED BY:  KEVIN PHILLIPS               |LAST UPDATE DATE:  06/11/2001|
|  HQ OPS OFFICER:  DOUG WEAVER                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          NON EMERGENCY         |BRIAN BONSER         R2      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(xi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       94       Power Operation  |94       Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| GRASS FIRE IN THE OWNER CONTROLLED AREA - OFFSITE NOTIFICATION               |
|                                                                              |
| The licensee called the Bethel Fire Department for help in extinguishing a   |
| grass fire on owner controlled property outside of the protected area.  No   |
| power lines were threatened.  The fire was put out in 34 minutes.            |
|                                                                              |
| The licensee also notified the States of North and South Carolina, the       |
| Counties of York, Gaston and Mecklenburg as well as the NRC resident         |
| inspector.                                                                   |
+------------------------------------------------------------------------------+


Page Last Reviewed/Updated Thursday, March 25, 2021

Page Last Reviewed/Updated Thursday, March 25, 2021