Event Notification Report for June 11, 2001
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
06/08/2001 - 06/11/2001
** EVENT NUMBERS **
37902 37920 38058 38059 38060
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37902 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: CRYSTAL RIVER REGION: 2 |NOTIFICATION DATE: 04/09/2001|
| UNIT: [3] [] [] STATE: FL |NOTIFICATION TIME: 11:08[EDT]|
| RXTYPE: [3] B&W-L-LP |EVENT DATE: 04/09/2001|
+------------------------------------------------+EVENT TIME: 09:54[EDT]|
| NRC NOTIFIED BY: RICHARD SWEENEY |LAST UPDATE DATE: 06/10/2001|
| HQ OPS OFFICER: STEVE SANDIN +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |CAUDLE JULIAN R2 |
|10 CFR SECTION: | |
|APRE 50.72(b)(2)(xi) OFFSITE NOTIFICATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|3 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION TO THE NATIONAL MARINE AND FISHERIES SERVICE AS A |
| RESULT OF THE ENDANGERED SEA TURTLES NON-LETHAL TAKE LIMIT BEING EXCEEDED |
| |
| "On April 09, 2001 at 0940 the 40th non-lethal sea turtle take in the |
| biennial period occurred. |
| |
| "In accordance with Crystal River Unit #3 Operating License, Appendix B, |
| Environmental Protection Plan (Non-Radiological), 'Endangered or threatened |
| sea turtles shall be protected in accordance with the Incidental Take |
| Statement issued by the National Marine and Fisheries Service (NMFS).' The |
| NMFS has established numerical limits on live takes, lethal takes causally |
| related to plant operation, and lethal takes not related to plant |
| operations. |
| |
| "The NMFS must be notified within five days whenever: |
| |
| a. The 40th non-lethal take occurs in the biennial period, or |
| b. The third causally related mortality occurs in the biennial period, or |
| c. The sixth non-causally related mortality occurs in the biennial |
| period. |
| |
| "The current biennial period for monitoring sea turtle takes began January |
| 1, 2001. |
| |
| "Thus, in accordance with Crystal Unit #3 Administrative Instruction 571, |
| Sea Turtle Rescue and Handling Guidance, the NMFS must be notified within |
| five days. |
| |
| "In accordance with Crystal River Unit #3 Compliance Procedure 151, External |
| Reporting Requirements, this 40th non-lethal sea turtle take is Reportable |
| as a 4-Hour Report under 10 CFR 50.72(b)(2)(xi) as this event is related to |
| the protection of the environment for which a notification to other |
| government agencies has been or will be made." |
| |
| The licensee will inform the NRC resident inspector. |
| |
| * * * UPDATE 0944EDT ON 4/10/01 FROM R. SWEENEY TO S. SANDIN * * * |
| |
| "On April 10, 2001 at 0859 the 41st non-lethal sea turtle take in the |
| biennial period occurred." |
| |
| The licensee informed the NRC resident inspector. Notified R2DO(Julian). |
| |
| ***** UPDATE RECEIVED AT 0911 ON 04/17/01 FROM CHRISTOPHER PELLERIN TO LEIGH |
| TROCINE ***** |
| |
| The 42nd, non-lethal, sea turtle take in the biennial period occurred at |
| 0810 on April 17, 2001. |
| |
| The licensee notified the NRC resident inspector. The NRC operations |
| officer notified the R2DO (Ernstes). |
| |
| * * * UPDATE 1125 EDT ON 5/1/01 FROM DAVID SCHULKER TO FANGIE JONES * * * |
| |
| "On May 1, 2001 at 0805 a turtle was identified as the 43rd rescued, live |
| sea turtle in this biennial period. This sea turtle will be kept for a |
| short observation period and then safely returned to the environment." |
| |
| The licensee will inform the NRC Resident Inspector and the National |
| Wildlife and Fisheries Service. Notified R2DO(Jay Henson). |
| |
| * * * UPDATE ON 5/29/01 BY FERGUSON TO SANDIN * * * |
| |
| On May 29, 2001 at 0943 two turtles were identified as the 44th and 45th |
| rescued, Iive Sea turtles in this biennial period. These healthy sea turtles |
| will be kept for a short observation period and then safely returned to the |
| environment. |
| |
| |
| This is Reportable as a 4-Hour Report under 10 CFR 50.72 (b) (2) (xi) as |
| this event is related to the protection of the environment for which a |
| notification to other government agencies has been or will be made. This is |
| an update to event 37902. |
| |
| The NRC Resident Inspector was notified. The REG2 RDO(Barr) was informed. |
| |
| * * * UPDATE 2014 EDT 6/4/2001 FROM RAWLS TAKEN BY STRANSKY * * * |
| |
| On June 4, 2001 at 1815, the 46th non-lethal sea turtle (Kemp's Ridley) take |
| in the biennial period occurred. The license has informed the NRC resident |
| inspector. Notified R2DO (Barr). |
| |
| * * * UPDATE 1315EDT ON 6/10/01 FROM CHARLES J. MORRIS TO S. SANDIN * * * |
| |
| On June 10, 2001 at 1100, the 47th non-lethal sea turtle take in the |
| biennial period occurred. The license has informed the NRC resident |
| inspector. Notified R2DO (Bonser). |
+------------------------------------------------------------------------------+
!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37920 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: MONTICELLO REGION: 3 |NOTIFICATION DATE: 04/15/2001|
| UNIT: [1] [] [] STATE: MN |NOTIFICATION TIME: 17:15[EDT]|
| RXTYPE: [1] GE-3 |EVENT DATE: 04/15/2001|
+------------------------------------------------+EVENT TIME: 11:50[CDT]|
| NRC NOTIFIED BY: DUSTIN WRIGHT |LAST UPDATE DATE: 06/08/2001|
| HQ OPS OFFICER: DOUG WEAVER +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |MICHAEL PARKER R3 |
|10 CFR SECTION: | |
|AINB 50.72(b)(3)(v)(B) POT RHR INOP | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| BOTH LOW PRESSURE COOLANT INJECTION (LPCI) PATHS TEMPORARILY INOPERABLE |
| |
| Procedure inadequacies for venting RHR System using Ops Manual B.08.01.03-05 |
| resulted in Tech Spec LCO(s) 3.5.A declaring both LPCI Injection Paths |
| inoperable (72 Hour LCO) and Tech Spec 3.5.C for one Division of |
| Containment Spray and Cooling inoperable (7 Day LCO) NOT entered. Contrary |
| to Ops Procedure #2145 RHR System Discharge Venting these LCO(s) should be |
| entered when RHR is vented. Notifications are being made because a vent |
| valve was opened which made both LPCI Injection Paths inoperable. This |
| condition at the time of discovery could have prevented the fulfillment of |
| the safety function or system that is needed for Residual Heat Capacity. |
| The vent valve is closed and verified closed. The RHR System is Operable |
| at this time. |
| |
| The licensee notified the NRC resident inspector. |
| |
| * * * UPDATE 1645EDT ON 6/8/01 FROM DUANE SCHMIDT TO S. SANDIN * * * |
| |
| The licensee is retracting this report based on the following: |
| |
| "On April 15, 2001, we reported that the opening of a vent valve made both |
| LPCI Injection Paths Inoperable causing the loss of the LPCI safety |
| function. This operation was a planned evolution in accordance with approved |
| procedures, as it was prescribed by the Operations Manual. As such, there |
| was not a loss of the LPCI safety function and thus this is not reportable |
| per the guidance in NUREG 1022, page 56." |
| |
| The licensee informed the NRC resident inspector. Notified R3DO(Clayton). |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 38058 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: DUANE ARNOLD REGION: 3 |NOTIFICATION DATE: 06/08/2001|
| UNIT: [1] [] [] STATE: IA |NOTIFICATION TIME: 00:41[EDT]|
| RXTYPE: [1] GE-4 |EVENT DATE: 06/07/2001|
+------------------------------------------------+EVENT TIME: 21:33[CDT]|
| NRC NOTIFIED BY: ROBINSON |LAST UPDATE DATE: 06/08/2001|
| HQ OPS OFFICER: CHAUNCEY GOULD +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |BRENT CLAYTON R3 |
|10 CFR SECTION: | |
|AIND 50.72(b)(3)(v)(D) ACCIDENT MITIGATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 47 Power Operation |47 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| HPCI DECLARED INOPERABLE DUE TO A FAULTY FLOW INDICATING SWITCH |
| |
| With DAEC operating in mode 1, at approximately 47% power, HPCI was declared |
| inoperable due to a faulty flow indicating switch which is utilized to |
| position the minimum flow valve. A 14-day LCO was entered per Technical |
| Specification 3.5.1, condition F, at 2133 on 6/7/01. This condition is |
| reportable under 50.72(b)(3)(v)(D) and 50.73(a)(2)(v)(D) as a failure of a |
| single train of equipment required to mitigate the consequences of an |
| accident. |
| |
| While an in-plant operator was performing his rounds within the HPCI room, |
| he discovered that flow indicating switch, FS2310, which should indicate |
| total HPCI flow, indicated approximately -170 gpm rather than the expected |
| zero gpm. The HPCI pump was not in operation. This flow switch is |
| interlocked with the HPCI minimum flow valve, allowing it to open with total |
| HPCI flow less than 300 gpm and HPCI discharge pressure greater than 125 |
| psig. The flow switch would close the minimum flow valve once HPCI total |
| flow reached 600 gpm. With the correct operation of the HPCI minimum flow |
| valve in question, HPCI was declared inoperable. |
| |
| It is believed that the cause of the faulty indication is air in the |
| instrument sensing lines feeding the flow switch. Troubleshooting efforts |
| will begin early tomorrow morning. |
| |
| The NRC Resident Inspector was notified |
| |
| |
| HOO NOTE: see event #38029 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 38059 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PILGRIM REGION: 1 |NOTIFICATION DATE: 06/08/2001|
| UNIT: [1] [] [] STATE: MA |NOTIFICATION TIME: 17:12[EDT]|
| RXTYPE: [1] GE-3 |EVENT DATE: 06/08/2001|
+------------------------------------------------+EVENT TIME: 16:15[EDT]|
| NRC NOTIFIED BY: ERIC OLSON |LAST UPDATE DATE: 06/08/2001|
| HQ OPS OFFICER: STEVE SANDIN +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |MICHELE EVANS R1 |
|10 CFR SECTION: |M. WAYNE HODGES NMSS |
|KSNM 70.52(a) LOSS OF SNM/CRIT |TAD MARSH NRR |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| SPECIAL NUCLEAR MATERIAL (SNM) REPORT INVOLVING 1 MILLIGRAM U-235 |
| |
| "During [the] process of replacing the 'A' Transverse In-Core Probe (TIP) |
| Detector, the old detector was removed and its serial number recorded. The |
| serial number was not the serial number expected. The expected serial |
| number was 6553444 and the detector that was removed had serial number |
| 6608500. The TIP detector is a fission chamber that utilizes approximately |
| 1 milligram of enriched uranium and is therefore treated as SNM. |
| |
| "During 1975 to 1986, Pilgrim did not track TIP detectors as SNM due to |
| being less than one gram of SNM. It is suspected that during this time |
| frame this detector was changed out. In 1987 a records search was made but |
| did not reveal maintenance performed on this detector. However, an |
| intensive records search will be performed as well as corrective actions yet |
| to be determined." |
| |
| The licensee informed the NRC resident inspector. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 38060 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: HATCH REGION: 2 |NOTIFICATION DATE: 06/10/2001|
| UNIT: [1] [2] [] STATE: GA |NOTIFICATION TIME: 11:12[EDT]|
| RXTYPE: [1] GE-4,[2] GE-4 |EVENT DATE: 06/10/2001|
+------------------------------------------------+EVENT TIME: 07:15[EDT]|
| NRC NOTIFIED BY: BRUCE BUTLER |LAST UPDATE DATE: 06/10/2001|
| HQ OPS OFFICER: LEIGH TROCINE +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: NON EMERGENCY |BRIAN BONSER R2 |
|10 CFR SECTION: |TAD MARSH NRR |
|ISFS 72.75 SPENT FUEL CASK EVENT |M. WAYNE HODGES NMSS |
| |JOSEPH HOLONICH IRO |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
|2 N Y 100 Power Operation |100 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| POSSIBLE SPENT FUEL STORAGE CAST DEFECT AND POTENTIAL SIGNIFICANT REDUCTION |
| IN EFFECTIVENESS OF THE SPENT FUEL STORAGE CASK CONFINEMENT SYSTEM DUE TO |
| FAILURE OF MULTI-PURPOSE CANISTER (MPC) VENT AND DRAIN CAPS TO FULLY CLOSE |
| (4-HOUR REPORT) |
| |
| As part of the dry storage project, the licensee has loaded one MPC-68. |
| (This MPC holds 68 fuel bundles.) Subsequent to system vacuum drying and |
| helium backfilling, the vent and drain caps failed to fully close (at 0715). |
| These caps are currently about half closed, and they appear to be stuck in |
| that position. |
| |
| At this time, the licensee is not aware of the loss of any helium. Licensee |
| personnel have snooped for helium in the area and near the fittings. |
| Licensee personnel are also currently in the process of installing pressure |
| gauges to verify that the proper amount of helium remains in the MPC. The |
| licensee plans to place a helium purge on the system if it is determined |
| that helium is being lost. The licensee also notified the cask supplier |
| (Holtec International). The supplier informed the licensee that the presents |
| of helium will keep the system closed. |
| |
| The technical specifications that apply to dry storage state that the MPC |
| shall be dry and helium filled, and a helium backfill density limit is also |
| specified. The licensee stated that this technical specification density |
| requirement was met before the attempt to close the vent and drain caps. |
| At this time, the licensee believes that this limit is still being met. |
| However, the licensee is not positive that this limit is being met with the |
| vent and drain caps in the current position. Therefore, the applicable |
| technical specification limiting condition for operation (LCO) was entered. |
| This LCO requires the licensee to perform an engineering evaluation to |
| determine the impact of helium differential within 72 hours and to develop |
| and initiate corrective actions necessary to return the MPC to an analyzed |
| condition within 14 days. |
| |
| In addition, the applicable technical specifications also specify an MPC |
| helium leak rate limit. The LCO for this specification was also entered. |
| It requires the licensee to perform an engineering evaluation to determine |
| the impact of increased helium leak rate on heat removal capability and |
| offsite dose within 24 hours and to develop and initiate corrective actions |
| necessary to return the MPC to an analyzed condition within 7 days. (The |
| supplier is currently performing an engineering evaluation for the licensee, |
| and the results are expected to be available later today.) |
| |
| The licensee is making this notification as a 4-hour report in accordance |
| with 10 CFR 72.216(a)(1) and (2) for any instance of a defect in any spent |
| fuel storage cask structure, system, or component which is important to |
| safety and for a significant reduction in the effectiveness of any spent |
| fuel storage cask confinement system during use of the storage cask under a |
| general license issued under 10 CFR 72.210. |
| |
| HOO NOTE: In accordance with 65 FR 63788 on 10/25/00, the reporting |
| requirements of 10 CFR 72.216 were revised (effective 01/23/01) to require |
| that licensees make initial and written reports in accordance with 10 CFR |
| 72.74 and 72.75. Therefore, more appropriate reporting requirements for |
| this 4-hour report are believed to be 10 CFR 72.75(b)(2) and (3). |
| |
| The licensee plans to notify the NRC resident inspector. |
+------------------------------------------------------------------------------+