Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for April 27, 2001

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           04/26/2001 - 04/27/2001

                              ** EVENT NUMBERS **

37823  37945  37946  37947  

!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED  !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37823       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: MONTICELLO               REGION:  3  |NOTIFICATION DATE: 03/10/2001|
|    UNIT:  [1] [] []                 STATE:  MN |NOTIFICATION TIME: 18:59[EST]|
|   RXTYPE: [1] GE-3                             |EVENT DATE:        03/10/2001|
+------------------------------------------------+EVENT TIME:        17:05[CST]|
| NRC NOTIFIED BY:  P DECKER                     |LAST UPDATE DATE:  04/26/2001|
|  HQ OPS OFFICER:  JOHN MacKINNON               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |JOHN MADERA          R3      |
|10 CFR SECTION:                                 |                             |
|*UNA 50.72(b)(3)(ii)(B)  UNANALYZED COND OP     |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Cold Shutdown    |0        Cold Shutdown    |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| DIFFERENTIAL PRESSURE TO OPEN THE SUPPRESSION CHAMBER TO DRYWELL VACUUM      |
| BREAKERS DISCREPANCIES WERE IDENTIFIED.                                      |
|                                                                              |
| During review of Inservice Testing requirements, while the plant was in      |
| shutdown, discrepancies were identified with acceptance criteria for the     |
| torque values used to determine the equivalent differential pressure to open |
| the suppression chamber to drywell vacuum breakers.  The measured torque     |
| values indicate that the differential pressure required to fully open the    |
| suppression chamber to drywell vacuum breakers would be greater than that    |
| assumed in containment analyses.  The suppression chamber to drywell vacuum  |
| breakers insure that the 2 psig external design pressure for the primary     |
| containment drywell suppression chamber and vent system is not exceeded and  |
| containment integrity is assured.                                            |
|                                                                              |
| The NRC Resident Inspector will be notified of this event by the licensee.   |
|                                                                              |
| * * * RETRACTION ON 04/23/01 AT 1805ET BY JIM MCKAY TAKEN BY MACKINNON * *   |
| *                                                                            |
|                                                                              |
| Retraction of notification made on March 10, 2001. The notification stated   |
| that discrepancies were identified with acceptance criteria for the torque   |
| values used to determine the equivalent differential pressure to open the    |
| suppression chamber to drywell vacuum breakers.  The measured values         |
| indicated a greater differential pressure required to fully open then        |
| assumed in containment analysis.  Upon further evaluation and review of the  |
| containment analyses, the results of the containment analysis were           |
| effectively independent and not adversely impacted by the suppression        |
| [chamber to drywell vacuum breaker full open differential pressure           |
| assumption in the range of concern.  Therefore, an unanalyzed condition that |
| significantly degrades the plant safety did not exist.]                      |
|                                                                              |
| R3DO (Tom Kozak) has been notified.                                          |
|                                                                              |
| NRC Resident Inspector will notified of this retraction by the licensee      |
|                                                                              |
| * * * UPDATE 1000EDT ON 4/26/01 TO S. SANDIN * * *                           |
|                                                                              |
| The above retraction was updated to include information shown in brackets    |
| which had been submitted but inadvertently omitted from the report.          |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Other Nuclear Material                           |Event Number:   37945       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  CROWE BUTTE RESOURCES                |NOTIFICATION DATE: 04/26/2001|
|LICENSEE:  CROWE BUTTE RESOURCES                |NOTIFICATION TIME: 15:29[EDT]|
|    CITY:  CRAWFORD                 REGION:  4  |EVENT DATE:        04/26/2001|
|  COUNTY:                            STATE:  NE |EVENT TIME:        11:30[CDT]|
|LICENSE#:  SUA-1534              AGREEMENT:  Y  |LAST UPDATE DATE:  04/26/2001|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |BILL JONES           R4      |
|                                                |JOHN HICKEY          NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  MIKE GRIFFIN                 |                             |
|  HQ OPS OFFICER:  DOUG WEAVER                  |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NMIN                     MINING EVENT           |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| LEAK IN BRINE POND LINER                                                     |
|                                                                              |
| The licensee has confirmed a leak in the pond liner based on an increase in  |
| the conductivity of the water between the inner and outer liners (the leak   |
| is in the inner liner).   No release to the environment has occurred.        |
| The licensee believes the leak is small based on the increase in             |
| conductivity with only a small accompanying increase in water level in the   |
| area between the liners.                                                     |
|                                                                              |
| The licensee will pump down the pond and attempt to find and repair the      |
| leak.  This could take one to two weeks.                                     |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Other Nuclear Material                           |Event Number:   37946       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  DELAWARE EMERG MANAGEMENT AGENCY     |NOTIFICATION DATE: 04/26/2001|
|LICENSEE:  UNKNOWN                              |NOTIFICATION TIME: 17:36[EDT]|
|    CITY:  NEW CASTLE               REGION:  1  |EVENT DATE:        04/26/2001|
|  COUNTY:                            STATE:  DE |EVENT TIME:             [EDT]|
|LICENSE#:                        AGREEMENT:  N  |LAST UPDATE DATE:  04/26/2001|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |DAVID SILK           R1      |
|                                                |JOSIE PICCONE        NMSS    |
+------------------------------------------------+RICHARD WESSMAN      IRO     |
| NRC NOTIFIED BY:  DAVID HAKE                   |                             |
|  HQ OPS OFFICER:  DOUG WEAVER                  |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NINF                     INFORMATION ONLY       |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| RECOVERY OF TROXLER GAUGE                                                    |
|                                                                              |
| The Delaware Emergency Management Agency (DEMA) reported the recovery of     |
| what appears to be a Troxler moisture density gauge.  The gauge was          |
| recovered in New Castle, DE just off of I-95.  The gauge appears to be       |
| intact with the source in the shielded position.  No model or serial numbers |
| were available.  DEMA requested NRC assistance to remove the gauge.  The     |
| gauge is isolated pending resolution.                                        |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37947       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: COOPER                   REGION:  4  |NOTIFICATION DATE: 04/26/2001|
|    UNIT:  [1] [] []                 STATE:  NE |NOTIFICATION TIME: 22:26[EDT]|
|   RXTYPE: [1] GE-4                             |EVENT DATE:        04/26/2001|
+------------------------------------------------+EVENT TIME:        17:45[CDT]|
| NRC NOTIFIED BY:  ANDREW OHRABLO               |LAST UPDATE DATE:  04/26/2001|
|  HQ OPS OFFICER:  DOUG WEAVER                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |BILL JONES           R4      |
|10 CFR SECTION:                                 |                             |
|*IND 50.72(b)(3)(v)(D)   ACCIDENT MITIGATION    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| CONTROL ROOM EMERGENCY FILTRATION SYSTEM (CREFS) INOPERABLE                  |
|                                                                              |
| The licensee entered a 7 day LCO when high vibrations were noticed on the    |
| booster fan.  The fan was declared inoperable and led to CREFS being         |
| declared inoperable since it is a single train system.  Licensee intends to  |
| repair the system prior to expiration of the LCO.                            |
|                                                                              |
| The licensee notified the NRC resident inspector.                            |
+------------------------------------------------------------------------------+