The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.
Event Notification Report for April 17, 2001
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
04/16/2001 - 04/17/2001
** EVENT NUMBERS **
37921 37922 37923
+------------------------------------------------------------------------------+
|Other Nuclear Material |Event Number: 37921 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: WASHINGTON UNIVERSITY |NOTIFICATION DATE: 04/16/2001|
|LICENSEE: WASHINGTON UNIVERSITY |NOTIFICATION TIME: 14:30[EDT]|
| CITY: ST. LOUIS REGION: 3 |EVENT DATE: 03/20/2001|
| COUNTY: STATE: MO |EVENT TIME: [CDT]|
|LICENSE#: 24-00167-11 AGREEMENT: N |LAST UPDATE DATE: 04/16/2001|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |RONALD GARDNER R3 |
| |DON COOL NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: SUE LANGHORSE | |
| HQ OPS OFFICER: BOB STRANSKY | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|BAB2 20.2201(a)(1)(ii) LOST/STOLEN LNM>10X | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| RADIOACTIVE MATERIAL DISCARDED AT SANITARY LANDFILL |
| |
| The licensee reported that one vial of P-32 (1 mCi) was inadvertently |
| discarded at a landfill. The licensee believes that the vial and the |
| shipping pig were left in the shipping box, which was placed in the trash. |
| The licensee was unable to locate the source before it was taken to the |
| landfill. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37922 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: FITZPATRICK REGION: 1 |NOTIFICATION DATE: 04/16/2001|
| UNIT: [1] [] [] STATE: NY |NOTIFICATION TIME: 15:17[EDT]|
| RXTYPE: [1] GE-4 |EVENT DATE: 04/16/2001|
+------------------------------------------------+EVENT TIME: [EDT]|
| NRC NOTIFIED BY: TIMOTHY PAGE |LAST UPDATE DATE: 04/16/2001|
| HQ OPS OFFICER: BOB STRANSKY +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |WILLIAM RULAND R1 |
|10 CFR SECTION: |VERN HODGE NRR |
|CCCC 21.21 UNSPECIFIED PARAGRAPH | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| 10 CFR PART 21 REPORT |
| |
| "This report is being submitted in accordance with 10CFR21.21(d) to address |
| a reportable defect. The defect deals with a replacement Foxboro |
| differential pressure transmitter that was found shorted to ground in the |
| conduit pressure seal assembly during the installation process." |
| |
| The NRC resident inspector will be informed of this report by the licensee. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Fuel Cycle Facility |Event Number: 37923 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PORTSMOUTH GASEOUS DIFFUSION PLANT |NOTIFICATION DATE: 04/17/2001|
| RXTYPE: URANIUM ENRICHMENT FACILITY |NOTIFICATION TIME: 05:46[EDT]|
| COMMENTS: 2 DEMOCRACY CENTER |EVENT DATE: 04/16/2001|
| 6903 ROCKLEDGE DRIVE |EVENT TIME: 07:10[EDT]|
| BETHESDA, MD 20817 (301)564-3200 |LAST UPDATE DATE: 04/17/2001|
| CITY: PIKETON REGION: 3 +-----------------------------+
| COUNTY: PIKE STATE: OH |PERSON ORGANIZATION |
|LICENSE#: GDP-2 AGREEMENT: N |RONALD GARDNER R3 |
| DOCKET: 0707002 |JOSEPHINE PICCONE NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: ERIC SPAETH | |
| HQ OPS OFFICER: STEVE SANDIN | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|NONR OTHER UNSPEC REQMNT | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| 24-HOUR REPORT INVOLVING A VALID ACTUATION OF A "Q" CLASS SAFETY SYSTEM |
| |
| "At 0710 hours on 04/16/01, Autoclave #4 in the X-344 UF6 Sampling Facility |
| had an 'AUTOCLAVE HI HI PRESSURE' alarm activation. This alarm initiates an |
| 'Autoclave Shell High Pressure Containment Shutdown', which causes the |
| autoclave containment isolation valves ('Q' components) to actuate. The |
| containment isolation valves closed, as designed. The initiating devices for |
| this alarm are redundant pressure switches with a TSR set point of 8.0 psig. |
| Autoclave #4 was in TSR Operational Mode IV (Feeding, Transfer, or Sampling) |
| at the time of the alarm activation. Operations personnel immediately |
| responded to the alarm in accordance with the approved Alarm Response |
| Procedures. Autoclave #4 was placed in TSR mode VII (Shutdown) by operations |
| personnel and declared inoperable by the Plant Shift Superintendent. |
| |
| "Instrument Maintenance was requested to perform 'as-founds' on the |
| 'Autoclave Pressure Loop Instrumentation'. The results of this data |
| indicated that the instrumentation associated with the 'Autoclave Internal |
| Pressure Loop' was found to be within acceptable 'as-found' tolerance. Based |
| on these results, this event is being reported as a valid safety system |
| actuation, a 24-hour NRC event. An Engineering Evaluation has been requested |
| to investigate the circumstances surrounding this safety system actuation." |
| |
| Operations will inform the DOE site representative and has informed the NRC |
| resident inspector. |
+------------------------------------------------------------------------------+
Page Last Reviewed/Updated Wednesday, March 24, 2021