The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.
Event Notification Report for April 12, 2001
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
04/11/2001 - 04/12/2001
** EVENT NUMBERS **
37672 37907 37908 37909 37910 37911 37912 37913
!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED !!!!!!!
+------------------------------------------------------------------------------+
|Hospital |Event Number: 37672 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: FROEDTERT MEMORIAL LUTHERAN HOSP |NOTIFICATION DATE: 01/19/2001|
|LICENSEE: FROEDTERT MEMORIAL LUTHERAN HOSP |NOTIFICATION TIME: 16:59[EST]|
| CITY: MILWAUKEE REGION: 3 |EVENT DATE: 01/17/2001|
| COUNTY: STATE: WI |EVENT TIME: 18:30[CST]|
|LICENSE#: 48-04193 AGREEMENT: N |LAST UPDATE DATE: 04/11/2001|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |ROGER LANKSBURY R3 |
| |ERIC LEEDS NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: MARCUM MARTZ | |
| HQ OPS OFFICER: DOUG WEAVER | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|LADM 35.33(a) MED MISADMINISTRATION | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| POTENTIAL MEDICAL MISADMINISTRATION |
| |
| A patient being treated with a Leksell gamma system model 23004 type B |
| received a treatment to the wrong site. The intended dose or dose delivered |
| were not available. The dose was delivered to the wrong location because |
| the head frame had been installed in the wrong position. The correct site |
| was subsequently treated. The hospital is in the process of informing the |
| patient and the referring physician. The attending physician did not |
| believe the mistake would pose a problem to the patient. |
| |
| ***** UPDATE AT 1439 EDT ON 04/11/01 FROM MARCUM MARTZ TO LEIGH TROCINE |
| ***** |
| |
| After discussions with the NRC Region 3 staff (Bob Gattone), it was |
| determined that this event did not involve a medical misadministration. |
| Therefore, the licensee is retracting this event notification. |
| |
| The NRC operations officer notified the R3DO (Wright) and NMSS EO (Smith). |
| |
| Call the NRC operations officer for a licensee contact telephone number. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37907 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: CALLAWAY REGION: 4 |NOTIFICATION DATE: 04/11/2001|
| UNIT: [1] [] [] STATE: MO |NOTIFICATION TIME: 05:55[EDT]|
| RXTYPE: [1] W-4-LP |EVENT DATE: 04/10/2001|
+------------------------------------------------+EVENT TIME: 19:50[CDT]|
| NRC NOTIFIED BY: SCOT MAGLIO |LAST UPDATE DATE: 04/11/2001|
| HQ OPS OFFICER: FANGIE JONES +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |MARK SHAFFER R4 |
|10 CFR SECTION: | |
|DDDD 73.71 UNSPECIFIED PARAGRAPH | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N N 0 Cold Shutdown |0 Cold Shutdown |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| SECURITY REPORT |
| |
| Safeguards system degradation related to monitoring. Immediate compensatory |
| measures taken upon discovery. |
| |
| The licensee intends to notify the NRC Resident Inspector. |
| |
| Refer to the HOO Log for additional details. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37908 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: OCONEE REGION: 2 |NOTIFICATION DATE: 04/11/2001|
| UNIT: [1] [2] [3] STATE: SC |NOTIFICATION TIME: 11:17[EDT]|
| RXTYPE: [1] B&W-L-LP,[2] B&W-L-LP,[3] B&W-L-L|EVENT DATE: 04/11/2001|
+------------------------------------------------+EVENT TIME: 10:35[EDT]|
| NRC NOTIFIED BY: BRAMLETT |LAST UPDATE DATE: 04/11/2001|
| HQ OPS OFFICER: CHAUNCEY GOULD +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |MIKE ERNSTES R2 |
|10 CFR SECTION: |ED GOODWIN NRR |
|DDDD 73.71 UNSPECIFIED PARAGRAPH | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
|2 N Y 99 Power Operation |99 Power Operation |
|3 N N 0 Cold Shutdown |0 Cold Shutdown |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| SECURITY REPORT |
| |
| Unescorted access granted inappropriately. Immediate compensatory measures |
| taken upon discovery. |
| |
| Refer to the HOO Log for additional details. |
| |
| The licensee notified the NRC Resident Inspector. |
| |
| See EN #37909. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37909 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: CATAWBA REGION: 2 |NOTIFICATION DATE: 04/11/2001|
| UNIT: [1] [2] [] STATE: SC |NOTIFICATION TIME: 11:30[EDT]|
| RXTYPE: [1] W-4-LP,[2] W-4-LP |EVENT DATE: 03/31/1999|
+------------------------------------------------+EVENT TIME: [EDT]|
| NRC NOTIFIED BY: JIMMY BURGESS |LAST UPDATE DATE: 04/11/2001|
| HQ OPS OFFICER: FANGIE JONES +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |MIKE ERNSTES R2 |
|10 CFR SECTION: | |
|DDDD 73.71 UNSPECIFIED PARAGRAPH | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
|2 N Y 100 Power Operation |100 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| SECURITY REPORT |
| |
| Unescorted access granted inappropriately. Immediate compensatory measures |
| taken upon discovery. |
| |
| Refer to the HOO Log for additional details. |
| |
| The licensee notified the NRC Resident Inspector. |
| |
| See EN #37908. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37910 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: WOLF CREEK REGION: 4 |NOTIFICATION DATE: 04/11/2001|
| UNIT: [1] [] [] STATE: KS |NOTIFICATION TIME: 11:37[EDT]|
| RXTYPE: [1] W-4-LP |EVENT DATE: 04/11/2001|
+------------------------------------------------+EVENT TIME: 04:50[CDT]|
| NRC NOTIFIED BY: SIMS |LAST UPDATE DATE: 04/11/2001|
| HQ OPS OFFICER: CHAUNCEY GOULD +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |MARK SHAFFER R4 |
|10 CFR SECTION: | |
|*COM 50.72(b)(3)(xiii) LOSS COMM/ASMT/RESPONSE| |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| LOSS OF EMERGENCY PLAN SIRENS |
| |
| The site reported the loss of six emergency plan sirens which constitutes a |
| major loss of emergency offsite communications for greater than one hour. |
| This was caused by a loss of power due to high winds and downed power lines. |
| Power was restored to the sirens at 0807 CDST. |
| |
| The NRC Resident Inspector was notified. The licensee will make a press |
| release to the news media. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37911 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: NINE MILE POINT REGION: 1 |NOTIFICATION DATE: 04/11/2001|
| UNIT: [1] [] [] STATE: NY |NOTIFICATION TIME: 12:06[EDT]|
| RXTYPE: [1] GE-2,[2] GE-5 |EVENT DATE: 04/11/2001|
+------------------------------------------------+EVENT TIME: 11:18[EDT]|
| NRC NOTIFIED BY: DON SHEEHAN |LAST UPDATE DATE: 04/11/2001|
| HQ OPS OFFICER: LEIGH TROCINE +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |JAMES LINVILLE R1 |
|10 CFR SECTION: | |
|*PRE 50.72(b)(2)(xi) OFFSITE NOTIFICATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N N 0 Cold Shutdown |0 Cold Shutdown |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| NATIONAL WEATHER SERVICE TONE-ALERT RADIOS OUT OF SERVICE FOR PLANNED |
| MAINTENANCE |
| |
| The following text is a portion of a facsimile received from the licensee: |
| |
| "[The] Emergency Planning Department at Nine Mile Point [Unit 1 was] |
| notified by Jim Holman of [the] Oswego County Emergency Planning Department |
| that the tone-alert radios for the National Weather Service (NWS) were out |
| of service (OOS) as of 1118 on 04/11/01 and are expected to be returned to |
| service (RTS) at 1400 on 04/11/01. The system was taken OOS for planned |
| maintenance. [The] Sheriff's Department [is] prepared to perform route |
| alerts if necessary per procedure EPIP-EPP-30 (Prompt Notification System |
| Problem Response). [The] control room [was] notified [of the event] at 1125 |
| on 04/11/01." |
| |
| "(10 CFR 50.72(b) and 10 CFR 50.72(a)(2) apply.)" |
| |
| The licensee notified the NRC resident inspector and county sheriff. The |
| licensee also plans to notify applicable local and state agencies. |
| |
| (Refer to event #37912 for a similar event notification from Fitzpatrick.) |
| |
| * * * UPDATE ON 4/11/01 AT 1523 BY SHEEHAN TO GOULD * * * |
| |
| The radio was back in service at 1515. |
| |
| The NRC Resident Inspector will be notified. Reg 1 RDO(Linville) was |
| notified |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37912 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: FITZPATRICK REGION: 1 |NOTIFICATION DATE: 04/11/2001|
| UNIT: [1] [] [] STATE: NY |NOTIFICATION TIME: 12:24[EDT]|
| RXTYPE: [1] GE-4 |EVENT DATE: 04/11/2001|
+------------------------------------------------+EVENT TIME: 11:18[EDT]|
| NRC NOTIFIED BY: NICHOLAS AVRAKOTOS |LAST UPDATE DATE: 04/11/2001|
| HQ OPS OFFICER: LEIGH TROCINE +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |JAMES LINVILLE R1 |
|10 CFR SECTION: | |
|*PRE 50.72(b)(2)(xi) OFFSITE NOTIFICATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| NATIONAL WEATHER SERVICE TONE-ALERT RADIOS OUT OF SERVICE FOR PLANNED |
| MAINTENANCE |
| |
| The following text is a portion of a facsimile received from the licensee: |
| |
| "[The] Control Room [and] Emergency Planning Department [were] notified (via |
| [the] Nine Mile Point Unit 1 Control Room) by Jim Holman of [the] Oswego |
| [County] Emergency Management Office that the tone-alert radios for the |
| National Weather Service (NWS) were out of service (OOS) as of 1118 on |
| 04/11/01 and are expected to be returned to service (RTS) at 1400 on |
| 04/11/01. The system was taken OOS for planned maintenance. [The] Oswego |
| Sheriff's Department is prepared to perform route alerts if necessary." |
| |
| "Review - 10 CFR 50.72(b) [and] 10 CFR 50.72(a)(2)" |
| |
| The licensee notified the NRC resident inspector and plans to notify |
| applicable local and state agencies. |
| |
| (Refer to event #37911 for a similar event notification from Nine Mile |
| Point.) |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37913 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: MONTICELLO REGION: 3 |NOTIFICATION DATE: 04/11/2001|
| UNIT: [1] [] [] STATE: MN |NOTIFICATION TIME: 19:01[EDT]|
| RXTYPE: [1] GE-3 |EVENT DATE: 04/11/2001|
+------------------------------------------------+EVENT TIME: 17:15[CDT]|
| NRC NOTIFIED BY: TIM WITSCHEN |LAST UPDATE DATE: 04/11/2001|
| HQ OPS OFFICER: LEIGH TROCINE +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |GEOFFREY WRIGHT R3 |
|10 CFR SECTION: | |
|*INC 50.72(b)(3)(v)(C) POT UNCNTRL RAD REL | |
|*IND 50.72(b)(3)(v)(D) ACCIDENT MITIGATION | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| FAILURE OF STANDBY GAS TREATMENT SYSTEM CHARCOAL FILTERS TO PASS A TECHNICAL |
| SPECIFICATION REQUIRED SURVEILLANCE |
| |
| The licensee reported that the 'A' train of standby gas treatment did not |
| pass a test involving an in-place charcoal absorber test with halogenated |
| hydrocarbon tracer (freon). This technical specification required |
| surveillance test is performed approximately every 18-months. |
| |
| The unit was placed in a 7-day limiting condition for operation for the 'A' |
| train of standby gas treatment prior to the test. The unit remains in that |
| LCO as a result of this test. The 'B' train is currently operable. |
| |
| The licensee's investigation is in progress. At this time, the licensee |
| believes that the problem is the result of bypass leakage. The licensee |
| plans to verify the root cause and retest the system tomorrow. |
| |
| This event was reported as an event or condition that at the time of |
| discovery could have prevented the fulfillment of the safety function of |
| structures or systems that are needed to control the release of radioactive |
| material and mitigate the consequences of an accident. |
| |
| The licensee notified the NRC resident inspector and plans to notify state |
| and local officials. |
+------------------------------------------------------------------------------+
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021