The U.S. Nuclear Regulatory Commission is in the process of rescinding or revising guidance and policies posted on this webpage in accordance with Executive Order 14151 Ending Radical and Wasteful Government DEI Programs and Preferencing, and Executive Order 14168 Defending Women From Gender Ideology Extremism and Restoring Biological Truth to the Federal Government. In the interim, any previously issued diversity, equity, inclusion, or gender-related guidance on this webpage should be considered rescinded that is inconsistent with these Executive Orders.

Event Notification Report for March 20, 2001

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           03/19/2001 - 03/20/2001

                              ** EVENT NUMBERS **

37848  37849  37850  37851  

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37848       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SUSQUEHANNA              REGION:  1  |NOTIFICATION DATE: 03/19/2001|
|    UNIT:  [] [2] []                 STATE:  PA |NOTIFICATION TIME: 10:44[EST]|
|   RXTYPE: [1] GE-4,[2] GE-4                    |EVENT DATE:        03/19/2001|
+------------------------------------------------+EVENT TIME:        08:00[EST]|
| NRC NOTIFIED BY:  ROBINSON                     |LAST UPDATE DATE:  03/19/2001|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |KENNETH JENISON      R1      |
|10 CFR SECTION:                                 |                             |
|*DEG 50.72(b)(3)(ii)(A)  DEGRAD COND DURING OP  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     N          N       0        Cold Shutdown    |0        Cold Shutdown    |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| SECONDARY CONTAINMENT BYPASS LEAKAGE RATE WAS EXCEEDED.                      |
|                                                                              |
| "With Unit 2 in Mode 5 on the 10th day of its 10th Refuel and Inspection     |
| Outage, it has been determined that the Secondary Containment Bypass Leakage |
| (SCBL) rate criteria of 9 scfh has been exceeded.   During performance of    |
| Local Leak Rate Test SE-259-045, a leakage rate of 3,838 sccm was recorded   |
| for the Division 2 RHR Drywell Spray Containment Isolation Valve HV251F016B. |
| With this leak rate, the Min Path SCBL leak rate was calculated to be 4,312  |
| sccm (or 9.14 scfh).  This leak rate exceeds the Technical Specification     |
| 3.6.1.3 criteria of 9 scfh for SCBL.  They will rework the valve and         |
| retest."                                                                     |
|                                                                              |
| The NRC Resident Inspector was notified.                                     |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37849       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: TURKEY POINT             REGION:  2  |NOTIFICATION DATE: 03/19/2001|
|    UNIT:  [3] [4] []                STATE:  FL |NOTIFICATION TIME: 11:10[EST]|
|   RXTYPE: [3] W-3-LP,[4] W-3-LP                |EVENT DATE:        03/19/2001|
+------------------------------------------------+EVENT TIME:        10:30[EST]|
| NRC NOTIFIED BY:  TODD YOUNG                   |LAST UPDATE DATE:  03/19/2001|
|  HQ OPS OFFICER:  BOB STRANSKY                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |ROBERT HAAG          R2      |
|10 CFR SECTION:                                 |                             |
|DDDD 73.71               UNSPECIFIED PARAGRAPH  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|3     N          Y       100      Power Operation  |100      Power Operation  |
|4     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| SECURITY REPORT                                                              |
|                                                                              |
| UNESCORTED ACCESS GRANTED INAPPROPRIATELY. IMMEDIATE COMPENSATORY MEASURES   |
| TAKEN UPON DISCOVERY. THE NRC RESIDENT INSPECTOR HAS BEEN INFORMED.          |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37850       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: VERMONT YANKEE           REGION:  1  |NOTIFICATION DATE: 03/19/2001|
|    UNIT:  [1] [] []                 STATE:  VT |NOTIFICATION TIME: 14:22[EST]|
|   RXTYPE: [1] GE-4                             |EVENT DATE:        03/19/2001|
+------------------------------------------------+EVENT TIME:        12:32[EST]|
| NRC NOTIFIED BY:  JAMES KRITZER                |LAST UPDATE DATE:  03/19/2001|
|  HQ OPS OFFICER:  DOUG WEAVER                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |KENNETH JENISON      R1      |
|10 CFR SECTION:                                 |                             |
|*RPS 50.72(b)(2)(iv)(B)  RPS ACTUATION - CRITICA|                             |
|*ESF 50.72(b)(3)(iv)(A)  VALID SPECIF SYS ACTUAT|                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     A/R        Y       100      Power Operation  |0        Hot Shutdown     |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| REACTOR SCRAM                                                                |
|                                                                              |
| On 3/19/2001, at 1232 a reactor scram signal was received, all rods inserted |
| after the scram.  Reactor Pressure Vessel  (RPV) water level dropped below   |
| 127" (normal water level is about 160") which actuated primary containment   |
| isolation signals for groups 2, 3 and 5.  RPV water level is being           |
| controlled by feedwater and RPV pressure control is via turbine bypass       |
| valves.  The plant is stable.  The cause of the reactor scram is under       |
| investigation.                                                               |
|                                                                              |
| The licensee notified the NRC resident inspector and will notify the state   |
| authorities.  A press release may be issued.                                 |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37851       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SOUTH TEXAS              REGION:  4  |NOTIFICATION DATE: 03/19/2001|
|    UNIT:  [] [2] []                 STATE:  TX |NOTIFICATION TIME: 18:02[EST]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        03/19/2001|
+------------------------------------------------+EVENT TIME:        10:57[CST]|
| NRC NOTIFIED BY:  JOHN CONLY                   |LAST UPDATE DATE:  03/19/2001|
|  HQ OPS OFFICER:  DOUG WEAVER                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |JOHN PELLET          R4      |
|10 CFR SECTION:                                 |                             |
|*DEG 50.72(b)(3)(ii)(A)  DEGRAD COND DURING OP  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     N          N       0        Refueling        |0        Refueling        |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| GREATER THAN 1% OF STEAM GENERATOR TUBES DEFECTIVE                           |
|                                                                              |
| "During refueling outage 2RE08, the results of steam generator tube          |
| inspections in steam generator 2C were classified as category C-3 in         |
| accordance with Technical Specification 4.4.5.2.d) in that 48 tubes out of   |
| 4,615 (i.e.,> 1%) have been found to be defective.   All defective steam     |
| generator tubes will be plugged before the steam generators are returned to  |
| service.  There were not any adverse safety consequences or implications as  |
| a result of this event.  This event did not adversely affect the safe        |
| operation of the plant or the health and safety of the public.  The cause of |
| the imperfections is outside diameter stress corrosion cracking."            |
|                                                                              |
| South Texas Project conducted a steam generator tube inspection results      |
| conference call with Region IV, the Senior Resident Inspector, and Nuclear   |
| Reactor Regulation this afternoon.   The occurrence of the C-3 condition was |
| noted during the call.                                                       |
+------------------------------------------------------------------------------+


Page Last Reviewed/Updated Thursday, March 25, 2021