Skip to main content

Alert

Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for March 5, 2001

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           03/02/2001 - 03/05/2001

                              ** EVENT NUMBERS **

37798  37799  37800  37801  37802  37803  37804  37805  

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37798       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SUSQUEHANNA              REGION:  1  |NOTIFICATION DATE: 03/02/2001|
|    UNIT:  [] [2] []                 STATE:  PA |NOTIFICATION TIME: 06:51[EST]|
|   RXTYPE: [1] GE-4,[2] GE-4                    |EVENT DATE:        03/02/2001|
+------------------------------------------------+EVENT TIME:        01:15[EST]|
| NRC NOTIFIED BY:  BOESCH                       |LAST UPDATE DATE:  03/02/2001|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |RICHARD CONTE        R1      |
|10 CFR SECTION:                                 |                             |
|*IND 50.72(b)(3)(v)(D)   ACCIDENT MITIGATION    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| BOTH PRIMARY CONTAINMENT HYDROGEN RECOMBINERS WERE DECLARED INOPERABLE.      |
|                                                                              |
| During operation of Unit 2 at 100% power, it has been determined that both   |
| Primary Containment Hydrogen Recombiners for the Suppression Pool Chamber    |
| are inoperable.  The 'A' recombiner had previously been removed from service |
| for maintenance activities, when the station's 'B' Emergency Diesel          |
| Generator was declared inoperable after the main control room received an    |
| unexpected trip alarm on the diesel.  The diesel failure is not reportable   |
| due to three diesels remaining operable.  However, Technical Specifications  |
| require that the 'B' recombiner be declared inoperable if the 'A' recombiner |
| is inoperable.  This failure requires a 8-hr ENS Notification under          |
| 10CFR50.72(b)(3)(v)(D), loss of a safety function to mitigate the            |
| consequences of an accident.  The 'B' Emergency Diesel was declared          |
| inoperable due to a failed relay.                                            |
|                                                                              |
| The NRC Resident Inspector was notified.                                     |
|                                                                              |
| Technical Specification 3.8.1, condition 'B,' required action b.2, states,   |
| "Declare the required feature supported by the inoperable diesel generator   |
| inoperable when the redundant required features are inoperable also."        |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37799       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PILGRIM                  REGION:  1  |NOTIFICATION DATE: 03/02/2001|
|    UNIT:  [1] [] []                 STATE:  MA |NOTIFICATION TIME: 10:10[EST]|
|   RXTYPE: [1] GE-3                             |EVENT DATE:        03/02/2001|
+------------------------------------------------+EVENT TIME:        05:30[EST]|
| NRC NOTIFIED BY:  KENNEDY                      |LAST UPDATE DATE:  03/02/2001|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |RICHARD CONTE        R1      |
|10 CFR SECTION:                                 |                             |
|*IND 50.72(b)(3)(v)(D)   ACCIDENT MITIGATION    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| PLANT DECLARED RCIC INOPERABLE.                                              |
|                                                                              |
| During a panel walkdown, it was discovered that the RCIC flow controller     |
| setpoint pointer was indicating erratically.  Therefore, the flow controller |
| was declared inoperable resulting in RCIC being declared inoperable.         |
| Troubleshooting is currently being performed on the controller.  This        |
| condition put the plant in a 14-day LCO action statement.                    |
|                                                                              |
| The NRC Resident Inspector will be notified.                                 |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   37800       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  NV DIV OF RAD HEALTH                 |NOTIFICATION DATE: 03/02/2001|
|LICENSEE:  DELTA GEOTECHNICAL CONSULTANTS, INC. |NOTIFICATION TIME: 13:30[EST]|
|    CITY:  LAS VEGAS                REGION:  4  |EVENT DATE:        03/02/2001|
|  COUNTY:  CLARK                     STATE:  NV |EVENT TIME:             [PST]|
|LICENSE#:  UT 18000038           AGREEMENT:  Y  |LAST UPDATE DATE:  03/02/2001|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |LINDA HOWELL         R4      |
|                                                |FRITZ STURZ          NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  STAN MARSHALL (VIA FAX)      |                             |
|  HQ OPS OFFICER:  STEVE SANDIN                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:                                |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT INVOLVING A STOLEN TROXLER GAUGE                      |
|                                                                              |
| Between 2300 PST on 3/1/01 and 0700 PST on 3/2/01, a  Troxler Model 3430     |
| gauge, S/N 25510, was stolen out of a Delta Geotechnical Consultants, Inc.   |
| pickup truck in Las Vegas, NV.  The licensee confirmed that the gauge was    |
| chained to the truck bed.  The Las Vegas Metro Police were informed.  Delta  |
| Geotechnical Consultants, Inc. is a Utah based corporation operating in      |
| Nevada under reciprocity of the Utah Rad. Material License.  This is NV      |
| Event Report ID No. NV 01-001.                                               |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Other Nuclear Material                           |Event Number:   37801       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  CROW BUTTE RESOURCES                 |NOTIFICATION DATE: 03/02/2001|
|LICENSEE:  CROW BUTTE RESOURCES                 |NOTIFICATION TIME: 15:06[EST]|
|    CITY:  CRAWFORD                 REGION:  4  |EVENT DATE:        03/02/2001|
|  COUNTY:                            STATE:  NE |EVENT TIME:        13:00[CST]|
|LICENSE#:  SUA-1534              AGREEMENT:  Y  |LAST UPDATE DATE:  03/02/2001|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |LINDA HOWELL         R4      |
|                                                |JOHN HICKEY          NMSS    |
+------------------------------------------------+BOB PIERSON (EMAIL)  NMSS    |
| NRC NOTIFIED BY:  MIKE GRIFFIN                 |                             |
|  HQ OPS OFFICER:  STEVE SANDIN                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NMIN                     MINING EVENT           |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| MONITOR WELL IN EXCURSION STATUS                                             |
|                                                                              |
| Crow Butte Resources shallow monitor well #SM6-13 in uranium solution mine   |
| unit #6 in Crawford, NE, was placed in excursion status due to sulfates      |
| concentration measuring 26 mg/l exceeding the UCL (Upper Control Limit) of   |
| 21 mg/l and the multiple chloride concentration measuring 9.1 mg/l exceeding |
| the UCL of 8 mg/l.  The licensee believes these are normal variations. A     |
| license amendment has been approved which would exclude reporting of normal  |
| variations.  However, since the NE UIC (Underground Injection Control)       |
| permit has not been modified, the licensee informed the NE DEQ (Department   |
| of Environmental Quality) Onsite Representative and will inform the NRC      |
| Project Manager.                                                             |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   37802       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  KANSAS DEPT OF HEALTH & ENVIRONMENT  |NOTIFICATION DATE: 03/02/2001|
|LICENSEE:  HUTCHINSON HOSPITAL CORPORATION      |NOTIFICATION TIME: 17:45[EST]|
|    CITY:  HUTCHINSON               REGION:  4  |EVENT DATE:        03/02/2001|
|  COUNTY:                            STATE:  KS |EVENT TIME:             [CST]|
|LICENSE#:  19-B081-01            AGREEMENT:  Y  |LAST UPDATE DATE:  03/02/2001|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |LINDA HOWELL         R4      |
|                                                |JOSEPH HOLONICH      NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  JAMES HARRIS                 |                             |
|  HQ OPS OFFICER:  STEVE SANDIN                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT INVOLVING POTENTIAL OVEREXPOSURE                      |
|                                                                              |
| The Kansas Department of Health and Environment was notified by Hutchinson   |
| Hospital Corporation that a Cardiologist may have received an overexposure.  |
| The source and extent of the potential overexposure are under investigation. |
| This is Kansas Case Number KS010006.  This report will be updated when more  |
| details are available.                                                       |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Fuel Cycle Facility                              |Event Number:   37803       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PORTSMOUTH GASEOUS DIFFUSION PLANT   |NOTIFICATION DATE: 03/02/2001|
|   RXTYPE: URANIUM ENRICHMENT FACILITY          |NOTIFICATION TIME: 20:58[EST]|
| COMMENTS: 2 DEMOCRACY CENTER                   |EVENT DATE:        03/01/2001|
|           6903 ROCKLEDGE DRIVE                 |EVENT TIME:        22:17[EST]|
|           BETHESDA, MD 20817    (301)564-3200  |LAST UPDATE DATE:  03/02/2001|
|    CITY:  PIKETON                  REGION:  3  +-----------------------------+
|  COUNTY:  PIKE                      STATE:  OH |PERSON          ORGANIZATION |
|LICENSE#:  GDP-2                 AGREEMENT:  N  |ANTON VEGEL          R3      |
|  DOCKET:  0707002                              |JOSEPH HOLONICH      NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  KEITH VANDERPOOL             |                             |
|  HQ OPS OFFICER:  STEVE SANDIN                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NONR                     OTHER UNSPEC REQMNT    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| NON-CFR REPORT INVOLVING A VALID ACTUATION OF A "Q" QUALITY CLASS SAFETY     |
| SYSTEM                                                                       |
|                                                                              |
| "On 3/1/01 at 2217 hours, Facility Operations Personnel received an alarm    |
| indicating that Cascade Automatic Data Processing (CADP) smoke head          |
| 'SXE-2783', located inside the housing near the LAW (low assay withdrawal)   |
| compressor 'AB', had actuated. Operations Personnel were taking actions to   |
| secure the LAW Station at the time of this actuation. Operations Personnel   |
| responded immediately to investigate the cause for the alarm. Upon arrival,  |
| no source for the alarm could be identified[.  The] smoke head reset at 2226 |
| hours. The PSS (plant shift superintendent) requested a firing plot for all  |
| smokeheads in the immediate area be printed for this time frame. The firing  |
| plots indicate that five (5) smokeheads did recognize activity however, the  |
| activity was minimal and did not actuate any other smoke heads. The PSS      |
| notified the Facility Operations Personnel of his findings and requested     |
| they have the housing panels removed for internal investigation to identify  |
| any evidence of out gassing. Upon completion of this investigation, it was   |
| identified that a minor out gassing had occurred. With this information this |
| event is reportable due to the valid actuation of a 'Q' Quality Class Safety |
| System."                                                                     |
|                                                                              |
| Operations personnel informed the NRC resident inspector.                    |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37804       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SUMMER                   REGION:  2  |NOTIFICATION DATE: 03/03/2001|
|    UNIT:  [1] [] []                 STATE:  SC |NOTIFICATION TIME: 03:37[EST]|
|   RXTYPE: [1] W-3-LP                           |EVENT DATE:        03/03/2001|
+------------------------------------------------+EVENT TIME:        02:50[EST]|
| NRC NOTIFIED BY:  DAN GOLDSTON                 |LAST UPDATE DATE:  03/03/2001|
|  HQ OPS OFFICER:  LEIGH TROCINE                +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |STEPHEN CAHILL       R2      |
|10 CFR SECTION:                                 |                             |
|*SHU 50.72(b)(2)(i)      PLANT S/D REQD BY TS   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       12       Power Operation  |11       Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| TECHNICAL SPECIFICATION REQUIRED SHUTDOWN DUE TO FAILURE OF TWO FEEDWATER    |
| FLOW CHANNELS TO RESPOND DURING A PLANT STARTUP                              |
|                                                                              |
| The following text is a portion of a facsimile and E-mail received from the  |
| licensee:                                                                    |
|                                                                              |
| "While performing a plant startup two channels of feedwater flow on [the] B  |
| Main Feed line failed to respond.  Investigation showed that both            |
| transmitter's output was too low to support operability.  These transmitters |
| provide the feed flow signal that, in conjunction with low steam generator   |
| water level, provide a reactor trip.  At 0225, [Technical Specification]     |
| 3.0.3 was entered, and power was reduced at 0250 to a nominal 11%."          |
|                                                                              |
| "We expect to complete calibration/repairs on at least one of the            |
| transmitter loops prior to 0725.  If at least one transmitter loop is not    |
| repaired, we must be in Hot Shutdown by 0925."                               |
|                                                                              |
| The licensee notified the NRC resident inspector.                            |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37805       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: COOPER                   REGION:  4  |NOTIFICATION DATE: 03/03/2001|
|    UNIT:  [1] [] []                 STATE:  NE |NOTIFICATION TIME: 18:48[EST]|
|   RXTYPE: [1] GE-4                             |EVENT DATE:        03/03/2001|
+------------------------------------------------+EVENT TIME:        10:28[CST]|
| NRC NOTIFIED BY:  JOHN MYERS                   |LAST UPDATE DATE:  03/03/2001|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |LINDA HOWELL         R4      |
|10 CFR SECTION:                                 |                             |
|*ESF 50.72(b)(3)(iv)(A)  VALID SPECIF SYS ACTUAT|                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Hot Shutdown     |0        Hot Shutdown     |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| VARIOUS SAFETY SYSTEM ACTUATIONS DURING A PLANNED SHUTDOWN                   |
|                                                                              |
| "While performing a planned shutdown for maintenance, an automatic scram and |
| group isolations occurred due to low Reactor water level.                    |
|                                                                              |
| "The sequence of events was as follows: Initial manual scram was inserted at |
| 09:42 CST to complete the shutdown as part of the plant shutdown procedure.  |
| Following the initial manual scram, 'B' Reactor Feed Pump (RFP) tripped on   |
| high water level. 'A' RFP was previously secured as part of the shutdown     |
| procedure. For undetermined reasons, 'B' RFP was unable to be returned to    |
| service. An attempt was made to start the 'A' RFP but efforts were stopped   |
| due to high vibrations received on 'A' RFP. Reactor Core Isolation Cooling   |
| (RCIC) was manually started to provide make up to the RPV [Reactor Pressure  |
| Vessel]. The subsequent shrink due to the relatively cool water being added  |
| caused water level to lower to the low level scram set point (level 3), and  |
| at 10:28 CST an automatic scram initiated, together with Group 2 (Primary    |
| Containment), Group 3 (Reactor Water Cleanup) and Group 6 (Secondary         |
| Containment) isolations. The Scram and automatic isolations functioned as    |
| designed, except Group 3 had been previously actuated due to high            |
| Non-regenerative Heat Exchanger temperature while initiating blowdown to the |
| main condenser for level control. Level was restored to approximately 17     |
| inches above the low level scram set point and the scram was reset. RCIC     |
| flow was lowered in anticipation of swell due to heating, and level again    |
| lowered. A manual scram was inserted approximately 4 inches prior to the low |
| level scram set point. Level was recovered using RCIC, and, following        |
| resetting of the scram, water level was restored to the normal level, RCIC   |
| secured, and condensate system used to raise level to the shutdown level     |
| band. Level is presently being maintained using the condensate system.       |
|                                                                              |
| "Investigation is on-going for the cause of being unable to restore 'B' RFP  |
| to service following the high level trip, and the reason for the high        |
| temperature isolation of RWCU [Reactor Water Cleanup].                       |
|                                                                              |
| "The Senior Resident Inspector has been notified."                           |
|                                                                              |
| The licensee is making preparations to place the unit in cold shutdown in    |
| the next 2-4 hours.                                                          |
+------------------------------------------------------------------------------+


Page Last Reviewed/Updated Thursday, March 25, 2021

Page Last Reviewed/Updated Thursday, March 25, 2021