The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.
Event Notification Report for February 14, 2001
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
02/13/2001 - 02/14/2001
** EVENT NUMBERS **
37731 37737 37738 37739 37740 37741 37742 37743
+------------------------------------------------------------------------------+
|Other Nuclear Material |Event Number: 37731 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: U.S. ARMY |NOTIFICATION DATE: 02/09/2001|
|LICENSEE: U.S. ARMY |NOTIFICATION TIME: 11:19[EST]|
| CITY: REGION: 3 |EVENT DATE: 02/08/2001|
| COUNTY: STATE: IL |EVENT TIME: [CST]|
|LICENSE#: 12-00722-06 AGREEMENT: Y |LAST UPDATE DATE: 02/13/2001|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |KEN BROCKMAN R4 |
| |DR. COOL NMSS |
+------------------------------------------------+BRENT CLAYTON R3 |
| NRC NOTIFIED BY: JOYCE KUYKENDALL | |
| HQ OPS OFFICER: DOUG WEAVER | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|BAB1 20.2201(a)(1)(i) LOST/STOLEN LNM>1000X | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| LOST SOURCE AT FT. RILEY, KANSAS |
| |
| The U.S. Army Aberdeen Proving Grounds reported the loss of a chemical agent |
| detector, model number M43A1. The detector contains 300 microcuries of |
| Am-241. The exact date, time and circumstances of the loss are not known. |
| |
| * * * UPDATE 1150EST ON 2/13/01 FROM JEFF HAVENNER TO S. SANDIN * * * |
| |
| The Rock Island Depot updated this report to provide the following |
| additional details: The detector was lost during an Infantry training |
| exercise. The unit involved is currently at Ft. Irwin, CA and unavailable |
| for questioning. The RSO at Ft. Riley intends to conduct a search of the |
| exercise area when the snow melts. Notified R1DO(Anderson), R3DO(Phillips) |
| and NMSS(Sturz). |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 37737 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: MA RADIATION CONTROL PROGRAM |NOTIFICATION DATE: 02/13/2001|
|LICENSEE: AEATECH QSA, INC. |NOTIFICATION TIME: 10:00[EST]|
| CITY: REGION: 1 |EVENT DATE: 02/12/2001|
| COUNTY: STATE: MA |EVENT TIME: 14:45[EST]|
|LICENSE#: 12-8361 AGREEMENT: Y |LAST UPDATE DATE: 02/13/2001|
| DOCKET: 99-0014 |+----------------------------+
| |PERSON ORGANIZATION |
| |CLIFFORD ANDERSON R1 |
| |GREG PICK R4 |
+------------------------------------------------+FREDRICK STURZ NMSS |
| NRC NOTIFIED BY: ROBERT GALLAGHAR | |
| HQ OPS OFFICER: JOHN MacKINNON | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|NAGR AGREEMENT STATE | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| SEALED SOURCE DELIVERED TO THE INCORRECT ADDRESS |
| |
| On 01/25/01 AEA Technology QSA, Inc., shipped a packaged 500 mCi |
| promethium-147 sealed source via FED EX to Impact Systems located in Los |
| Gatos, CA. On 02/01/2001 Impact Systems called AEA Technology QSA asking |
| where the package was. AEA Technology QSA, Inc., contacted FED EX and was |
| informed that the package had been delivered to Fastech Integration, Inc., |
| located at 101 Albright St., Los Gatos, CA. |
| |
| FED EX went back to the address to reclaim the package and to complete the |
| delivery to Impact Systems. FED EX said that they would notify AEA |
| Technology QSA, Inc., and let them know if there was a problem. |
| |
| AEA Technology QSA, Inc., received a second call from Impact Systems on |
| 02/07/01 asking where the package was. AEA Technology QSA, Inc., |
| immediately contacted FED EX on 02/07/01. On 02/12/01 FED EX informed AEA |
| Technology QSA, Inc., that they had gone back to Fastech Integration, Inc., |
| and spoke to the individual who has signed for the package, but the receiver |
| stated she did not have the package. |
| |
| The State of Massachusetts informed the State of California of this event |
| and are still following up on this event. |
| |
| * * * UPDATE AT 1511 EST ON 2/13/01 BY ROBERT GALLAGHAR TO FANGIE JONES * * |
| * |
| |
| The source has been located by Fastech Integration, Inc. and delivered to |
| Impact Systems, the company that ordered the source. The package was |
| intact. The State of Massachusetts will inform the State of California of |
| the event update. |
| |
| The R1DO (Clifford Anderson), R4DO (Greg Pick), and NMSS (Fred Sturz) have |
| been informed. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37738 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SAINT LUCIE REGION: 2 |NOTIFICATION DATE: 02/13/2001|
| UNIT: [1] [2] [] STATE: FL |NOTIFICATION TIME: 10:57[EST]|
| RXTYPE: [1] CE,[2] CE |EVENT DATE: 02/13/2001|
+------------------------------------------------+EVENT TIME: 10:40[EST]|
| NRC NOTIFIED BY: JACK BREEN |LAST UPDATE DATE: 02/13/2001|
| HQ OPS OFFICER: JOHN MacKINNON +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |KEN BARR R2 |
|10 CFR SECTION: | |
|*PRE 50.72(b)(2)(xi) OFFSITE NOTIFICATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
|2 N Y 100 Power Operation |100 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| FLORIDA FISH AND WILDLIFE CONSERVATION COMMISSION WAS NOTIFIED THAT A SICK |
| SEA TURTLE NEEDED REHABILITATION. |
| |
| The licensee rescued a sea turtle from the intake canal. As a result, the |
| licensee notified the Florida Fish and Wildlife Conservation Commission that |
| the turtle had been rescued and needed rehabilitation. |
| |
| The resident inspector was notified of this event by the licensee. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 37739 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: COOPER POWER SYSTEMS INC |NOTIFICATION DATE: 02/13/2001|
|LICENSEE: COOPER POWER SYSTEMS INC |NOTIFICATION TIME: 11:53[EST]|
| CITY: FRANKSVILLE REGION: 3 |EVENT DATE: 01/18/2001|
| COUNTY: STATE: WI |EVENT TIME: [CST]|
|LICENSE#: 48-173-83-02 AGREEMENT: N |LAST UPDATE DATE: 02/13/2001|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |MONTE PHILLIPS R3 |
| |FRITZ STURZ NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: OWEN | |
| HQ OPS OFFICER: CHAUNCEY GOULD | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|BAB2 20.2201(a)(1)(ii) LOST/STOLEN LNM>10X | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| THE LICENSEE REPORTED A MISSING ELECTRON CAPTURE DETECTOR |
| |
| During a physical inventory of radiation sources, the licensee reported that |
| an electron capture detector for a gas chromatograph, used in a chem lab, |
| was missing on the last inventory performed on 01/18/01. The device was a |
| PerkinElmer model PE009-0282 serial # 1648 containing Ni-63 <15 millicuries. |
| A search was made, but the device did not show up. It was last inventoried |
| approximately three years ago. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Hospital |Event Number: 37740 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: UNION HOSPITAL |NOTIFICATION DATE: 02/13/2001|
|LICENSEE: UNION HOSPITAL |NOTIFICATION TIME: 15:42[EST]|
| CITY: TERRE HAUTE REGION: 3 |EVENT DATE: 02/13/2001|
| COUNTY: VIGO STATE: IN |EVENT TIME: [CST]|
|LICENSE#: 12-16457-01 AGREEMENT: N |LAST UPDATE DATE: 02/13/2001|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |MONTE PHILLIPS R3 |
| |E. WILLIAM BRACH NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: DEAN TAYLOR | |
| HQ OPS OFFICER: FANGIE JONES | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|BAB2 20.2201(a)(1)(ii) LOST/STOLEN LNM>10X | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| LOST SOURCE - SEED USED FOR PROSTATE PROCEDURE |
| |
| The hospital discovered that one seed out of 110 seeds, apparent activity is |
| .311 mCi I-125 (full activity is .587 mCi) was missing after the completion |
| of an implant procedure. An extensive search of the operating room, |
| equipment, drains, laundry, and hallways failed to discover the missing |
| seed. The patient was scanned and the best analysis is that the patient |
| received the proper number of seeds. There is little or no threat to the |
| public health or safety. The hospital contacted NRC Region 3. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 37741 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: ARIZONA RADIATION REGULATORY AGENCY |NOTIFICATION DATE: 02/13/2001|
|LICENSEE: RICKER-ATKINSON-McBEE & ASSOC. |NOTIFICATION TIME: 17:11[EST]|
| CITY: REGION: 4 |EVENT DATE: 02/13/2001|
| COUNTY: STATE: AZ |EVENT TIME: [MST]|
|LICENSE#: 07-406 AGREEMENT: Y |LAST UPDATE DATE: 02/13/2001|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |GREG PICK R4 |
| |E. WILLIAM BRACH NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: WILLIAM WRIGHT | |
| HQ OPS OFFICER: FANGIE JONES | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|NAGR AGREEMENT STATE | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT OF A STOLEN TROXLER GAUGE |
| |
| "This first notice constitutes EARLY notice of events of POSSIBLE safety or |
| public interest significance. The information is that which is available |
| after preliminary investigation and is basically all that is known by the |
| Agency Staff at this time. |
| |
| "Date: 02/13/01 |
| Time: 0430-0815 AM, MST |
| First Notice No. 01-01: |
| |
| "Arizona Licensee: Ricker-Atkinson-McBee & Assoc. |
| License: No. 07-406 |
| |
| "Description of the event: Between the hours of 0430 AM and 0815 AM a |
| Troxler Moisture Density Gauge, Model #3440, S/N 26981 was stolen from the |
| licensee's facility while locked and chained in the bed of the users 2000 |
| Dodge Dakota Pickup Truck, Arizona Lic. #523FCY. The gauge and scatter block |
| were removed from the transport case and the case remained in the pickup. A |
| reward of $500.00 is being offered by the licensee upon return of the |
| gauge. |
| |
| "The states of Utah, California, Colorado, New Mexico, and U.S. NRC Region |
| IV, USNRC-DC, USFBI and the governor's office are being informed of this |
| incident." |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37742 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: WATERFORD REGION: 4 |NOTIFICATION DATE: 02/13/2001|
| UNIT: [3] [] [] STATE: LA |NOTIFICATION TIME: 21:18[EST]|
| RXTYPE: [3] CE |EVENT DATE: 02/13/2001|
+------------------------------------------------+EVENT TIME: 16:54[CST]|
| NRC NOTIFIED BY: CHARLES DeDEAUX |LAST UPDATE DATE: 02/13/2001|
| HQ OPS OFFICER: FANGIE JONES +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |GREG PICK R4 |
|10 CFR SECTION: | |
|*RPS 50.72(b)(2)(iv)(B) RPS ACTUATION - CRITICA| |
|*ESF 50.72(b)(3)(iv)(A) VALID SPECIF SYS ACTUAT| |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|3 A/R Y 82 Power Operation |0 Hot Standby |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| AUTOMATIC REACTOR TRIP DURING TURBINE VALVE TESTING |
| |
| "On 2/13/2001 at 1654 CST Waterford 3 sustained a reactor trip from 82% RTP. |
| The reactor trip was most probably caused by variable over power trip, which |
| is a core protection calculator auxiliary trip. Actuation of the emergency |
| feedwater system also occurred due to shrinkage of coolant in the steam |
| generator caused by the reactor trip; however, no emergency feedwater was |
| actually fed into the steam generators. Actuation of the emergency feedwater |
| system is a normal occurrence following a reactor trip. This condition is |
| reportable under 10CFR50.72(b)(2)(iv)(B), any event or condition that |
| results in actuation of the reactor protection system when the reactor is |
| critical, which is a 4 hour report; and 10CFR50.72(b)(3)(iv)(A), any event |
| or condition that results in valid actuation of the emergency feedwater |
| system, which is an 8 hour report. At the time of the trip Waterford 3 was |
| performing turbine valve testing per OP-903-007. Governor Valve 3 was being |
| tested and sporadically started opening and closing." |
| |
| The plant is stable in Hot Standby with excess heat removed via forced |
| circulation to the steam generators and steam released through the bypasses |
| to the main condensers. |
| |
| The licensee notified the NRC Resident Inspector. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37743 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: INDIAN POINT REGION: 1 |NOTIFICATION DATE: 02/14/2001|
| UNIT: [2] [] [] STATE: NY |NOTIFICATION TIME: 02:51[EST]|
| RXTYPE: [2] W-4-LP,[3] W-4-LP |EVENT DATE: 02/14/2001|
+------------------------------------------------+EVENT TIME: 01:50[EST]|
| NRC NOTIFIED BY: MARK LEONE |LAST UPDATE DATE: 02/14/2001|
| HQ OPS OFFICER: LEIGH TROCINE +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |CLIFFORD ANDERSON R1 |
|10 CFR SECTION: | NRR |
|*ESF 50.72(b)(3)(iv)(A) VALID SPECIF SYS ACTUAT| |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|2 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| THE LOSS OF A 480-VOLT BUS DUE TO A PERSONNEL ERROR DURING SURVEILLANCE |
| TESTING RESULTED IN THE AUTOMATIC START OF THREE EMERGENCY DIESEL |
| GENERATORS. |
| |
| At 0150 on 02/14/01, 480-volt bus 3A was lost due to incorrect operation of |
| a switch during performance of a surveillance test. An individual |
| performing the test needed to simultaneously hold a switch in the bypass |
| position while a test button was pressed, and the switch was not held in the |
| correct position. As a result, an undervoltage signal was inserted on the |
| bus when the test button was pushed, and all three emergency diesel |
| generators automatically started as designed. |
| |
| The licensee stated that the emergency diesel generators do not |
| automatically load on the loss of an internal bus and that all automatic |
| functions operated properly. The licensee also stated that the loss of any |
| 480-volt bus places the unit in a shutdown action statement in accordance |
| with Technical Specification 3.0.1. However, power (via an emergency diesel |
| generator) was restored to the bus in accordance with procedures at 0215, |
| and restoration of power satisfied the action statement requirements in |
| Technical Specification 3.0.1 within 25 minutes. The licensee is currently |
| in the process of restoring normal bus power supply. |
| |
| The licensee stated that bus 3A is one of the power supplies for the 22 |
| safety injection pump. This bus also supplies power to the 21 residual heat |
| removal pump, 22 and 25 service water pumps, 24 fan cooler unit, 21 |
| auxiliary boiler feed pump, 22 charging pump, 21 backup heater for the |
| pressurizer, and 23 instrument bus (via the 23 battery charger). |
| |
| The licensee plans to notify the NRC resident inspector and applicable |
| government agencies. The licensee may also issue a press release. |
+------------------------------------------------------------------------------+
Page Last Reviewed/Updated Wednesday, March 24, 2021
Page Last Reviewed/Updated Wednesday, March 24, 2021