Skip to main content

Alert

Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for February 9, 2001

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           02/08/2001 - 02/09/2001

                              ** EVENT NUMBERS **

37727  37728  37729  

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37727       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SUSQUEHANNA              REGION:  1  |NOTIFICATION DATE: 02/08/2001|
|    UNIT:  [] [2] []                 STATE:  PA |NOTIFICATION TIME: 17:35[EST]|
|   RXTYPE: [1] GE-4,[2] GE-4                    |EVENT DATE:        02/08/2001|
+------------------------------------------------+EVENT TIME:        14:47[EST]|
| NRC NOTIFIED BY:  ROLAND                       |LAST UPDATE DATE:  02/08/2001|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |RONALD BELLAMY       R1      |
|10 CFR SECTION:                                 |                             |
|ADEG 50.72(b)(1)(ii)     DEGRAD COND DURING OP  |                             |
|AINC 50.72(b)(2)(iii)(C) POT UNCNTRL RAD REL    |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| BOTH REACTOR RECIRCULATING SAMPLE LINE CONTAINMENT ISOLATION VALVES DECLARED |
| INOPERABLE                                                                   |
|                                                                              |
| During operation of Unit 2 at 100% power, it has been determined that both   |
| Primary Containment Isolation Valves for the Reactor Recirculating Sample    |
| Line are inoperable.  During restoration from maintenance activities on the  |
| line, the outboard isolation valve[HV243F020] failed to stroke closed.       |
| Following several attempts the valve was closed.  The valve was declared     |
| inoperable, and as required by Technical Specifications an attempt was made  |
| to close the inboard isolation valve[HV243F019].  The inboard valve also     |
| failed to close.  The air supply was isolated to the outboard valve to       |
| deactivate it, and the pathway was confirmed to be isolated.  The problem    |
| with the outboard valve is due to a bad solenoid.   The problem with the     |
| inboard valve is under investigation.  They were able to get both valves     |
| closed when the inboard valve finally closed on its own an hour later.       |
|                                                                              |
| The NRC Resident Inspector was notified.                                     |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37728       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: COOK                     REGION:  3  |NOTIFICATION DATE: 02/08/2001|
|    UNIT:  [1] [] []                 STATE:  MI |NOTIFICATION TIME: 20:07[EST]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        02/08/2001|
+------------------------------------------------+EVENT TIME:        19:00[EST]|
| NRC NOTIFIED BY:  FOSTER                       |LAST UPDATE DATE:  02/08/2001|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |BRENT CLAYTON        R3      |
|10 CFR SECTION:                                 |TAD MARSH            NRR     |
|ASHU 50.72(b)(1)(i)(A)   PLANT S/D REQD BY TS   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |60       Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| PLANT DECLARED SSPS(SOLID STATE PROTECTION SYSTEM) INOPERABLE                |
|                                                                              |
| Reactor shutdown was initiated at 1900 due to train "B" SSPS being declared  |
| inoperable.  Technical Specifications 3.3.1.1 and 3.3.2.1, which were        |
| entered at 1628, requires the Unit to be in hot standby within 6 hours.      |
| The problem was caused by a redundant power supply to the "B" train being    |
| declared inoperable, and an incorrect procedure.  Procedure changes are      |
| currently being developed to correct it.                                     |
|                                                                              |
| The NRC Resident Inspector was notified.                                     |
|                                                                              |
| * * * UPDATE ON 2/8/01 BY JOHNSON TO GOULD * * *                             |
|                                                                              |
| Procedural changes were complete at 2030 and power reduction was terminated  |
| at 58% and power was stabilized between 50 and 55 percent.  The plant will   |
| maintain that power level until feed pump repairs are complete(approx. 4-5   |
| hrs).                                                                        |
|                                                                              |
| The NRC Resident Inspector was notified.                                     |
|                                                                              |
| The Reg 3 RDO(Clayton) and NRR EO(Marsh) were informed.                      |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   37729       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  DRAPER ADEN ASSOCIATES               |NOTIFICATION DATE: 02/08/2001|
|LICENSEE:  DRAPER ADEN ASSOCIATES               |NOTIFICATION TIME: 23:09[EST]|
|    CITY:  RICHMOND                 REGION:  2  |EVENT DATE:        02/08/2001|
|  COUNTY:                            STATE:  VA |EVENT TIME:        21:00[EST]|
|LICENSE#:  45-25246-01           AGREEMENT:  N  |LAST UPDATE DATE:  02/08/2001|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |RONALD BELLAMY       R1      |
|                                                |PHILIP TING          NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  WEIFORD                      |                             |
|  HQ OPS OFFICER:  CHAUNCEY GOULD               |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NINF                     INFORMATION ONLY       |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| LOST TROXLER GAUGE                                                           |
|                                                                              |
| The licensee reported that a Troxler model 3411 serial #16727 (8.5           |
| millicuries Cs-137 and 40 millicuries Am-241 Be) fell out of the back of an  |
| employees truck between work and home (approx. 15 to 20 miles).  They made a |
| search of the route taken by the employee, but they did not find it.  The    |
| licensee notified the local police department.                               |
+------------------------------------------------------------------------------+


Page Last Reviewed/Updated Thursday, March 25, 2021

Page Last Reviewed/Updated Thursday, March 25, 2021