Event Notification Report for January 10, 2001
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
01/09/2001 - 01/10/2001
** EVENT NUMBERS **
37657 37658
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37657 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: DRESDEN REGION: 3 |NOTIFICATION DATE: 01/09/2001|
| UNIT: [] [] [3] STATE: IL |NOTIFICATION TIME: 08:13[EST]|
| RXTYPE: [1] GE-1,[2] GE-3,[3] GE-3 |EVENT DATE: 01/09/2001|
+------------------------------------------------+EVENT TIME: 04:01[CST]|
| NRC NOTIFIED BY: RUNION |LAST UPDATE DATE: 01/09/2001|
| HQ OPS OFFICER: FANGIE JONES +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |JOHN JACOBSON R3 |
|10 CFR SECTION: | |
|AINC 50.72(b)(2)(iii)(C) POT UNCNTRL RAD REL | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
| | |
| | |
|3 N Y 100 Power Operation |100 Power Operation |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| ISOLATION CONDENSER STEAM CONDENSATE HIGH FLOW SWITCHES OUT OF CALIBRATION |
| |
| "During performance of DIS 1300-07, Isolation Condenser Steam Condensate |
| High Flow Switch Calibration, DP switch 3-1349A as found trip setpoint was |
| outside of T.S. limits. The as found value was -17.5 in WC and the T.S. |
| limit is </= to 14.8 in WC. Later in the same surveillance, DP switch |
| 3-1349B as found trip setpoint was outside of T.S. limit is </= 14.8 in WC. |
| These are the Div 1 and Div 2 Isolation Condenser Condensate High Flow |
| isolation instruments. With both these switches inop, the Isolation |
| Condenser would not have isolated at the appropriate time on a valid high |
| condensate flow signal. The Isolation Condenser was already isolated when |
| the out of tolerance switches were discovered and the switches were |
| calibrated satisfactorily prior to unisolating the Isolation Condenser." |
| |
| The licensee notified the NRC Resident Inspector. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37658 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PERRY REGION: 3 |NOTIFICATION DATE: 01/09/2001|
| UNIT: [1] [] [] STATE: OH |NOTIFICATION TIME: 13:08[EST]|
| RXTYPE: [1] GE-6 |EVENT DATE: 01/09/2001|
+------------------------------------------------+EVENT TIME: 12:20[EST]|
| NRC NOTIFIED BY: ROBERT KIDDER |LAST UPDATE DATE: 01/09/2001|
| HQ OPS OFFICER: BOB STRANSKY +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |JOHN JACOBSON R3 |
|10 CFR SECTION: |ED GOODWIN NRR |
|KSNM 70.52(a) LOSS OF SNM/CRIT |FRITZ STURZ NMSS |
|KFIS 70.52(b) LOSS OF SNM/FISSILE |JOSEPH GIITTER IRO |
|DDDD 73.71 UNSPECIFIED PARAGRAPH |ROBERT SKELTON IAT |
| |JOHN DAVIDSON IAT |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 87 Power Operation |87 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| NEUTRON MONITORING DETECTOR MISSING FROM SHIPMENT |
| |
| The licensee reported that one local power range monitor (LPRM) detector was |
| missing out of a shipment from GE Reuter-Stokes in Twinsburg, OH. The |
| missing detector contains 0.00027g of U-235 (0.00121g total U) in the form |
| of solid uranium oxide. The licensee has contacted the vendor to determine |
| whether an error occurred in preparation of the shipping papers. The NRC |
| resident inspector will be informed of this event by the licensee. |
| |
| * * * UPDATE 1529 FROM KIDDER TAKEN BY STRANSKY * * * |
| |
| At 1355, the licensee was informed that the missing LPRM detector is |
| currently located at the GE Reuter-Stokes facility and had not been shipped. |
| The NRC resident inspector has been informed of this update. Notified R3DO |
| (Jacobson). |
+------------------------------------------------------------------------------+