Event Notification Report for November 29, 2000
U.S. Nuclear Regulatory Commission Operations Center Event Reports For 11/28/2000 - 11/29/2000 ** EVENT NUMBERS ** 37554 37555 +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 37554 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: PILGRIM REGION: 1 |NOTIFICATION DATE: 11/28/2000| | UNIT: [1] [] [] STATE: MA |NOTIFICATION TIME: 16:50[EST]| | RXTYPE: [1] GE-3 |EVENT DATE: 11/28/2000| +------------------------------------------------+EVENT TIME: 15:13[EST]| | NRC NOTIFIED BY: BOB COOLIDGE |LAST UPDATE DATE: 11/28/2000| | HQ OPS OFFICER: STEVE SANDIN +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |ANIELLO DELLA GRECA R1 | |10 CFR SECTION: | | |AIND 50.72(b)(2)(iii)(D) ACCIDENT MITIGATION | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 100 Power Operation |100 Power Operation | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | HIGH PRESSURE COOLANT INJECTION (HPCI) DECLARED INOPERABLE DUE TO | | INSTRUMENTATION FAILURE | | | | "The HPCI System was taken out of service for surveillance testing earlier | | in the day. The surveillance's were completed and HPCI was placed back in | | service in standby lineup. At this time, the high flow isolation | | instrumentation was found to be reading well beyond the limits of the normal | | in service band (+10 to -10). At that time, HPCI was removed from service | | (availability) and isolated. The proper LCO was entered and troubleshooting | | is underway." | | | | The licensee informed the NRC resident inspector. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 37555 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: MCGUIRE REGION: 2 |NOTIFICATION DATE: 11/28/2000| | UNIT: [1] [2] [] STATE: NC |NOTIFICATION TIME: 17:16[EST]| | RXTYPE: [1] W-4-LP,[2] W-4-LP |EVENT DATE: 11/28/2000| +------------------------------------------------+EVENT TIME: 16:25[EST]| | NRC NOTIFIED BY: JOHN SMALL |LAST UPDATE DATE: 11/28/2000| | HQ OPS OFFICER: STEVE SANDIN +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |GEORGE BELISLE R2 | |10 CFR SECTION: | | |AOUT 50.72(b)(1)(ii)(B) OUTSIDE DESIGN BASIS | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 100 Power Operation |100 Power Operation | |2 N Y 100 Power Operation |100 Power Operation | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | BOTH UNITS OUTSIDE OF DESIGN BASIS DUE TO MOMENTARY LOSS OF BOTH TRAINS OF | | CONTROL ROOM VENTILATION | | | | "Presently, 'A' Control Room Ventilation out of service for maintenance. | | 'B' Control Room Ventilation (VC/YC) inadvertently deenergized causing both | | trains of VC/YC to be inoperable. 'B' VC/YC restarted with no further | | complications. Deenergized from 1625 until 1643 which places both units one | | and two outside design basis. With VC/YC inoperable for 'A' and 'B' trains, | | entered [TS] 3.0.3 momentarily." | | | | The problem occurred when the technician performing maintenance on the "A" | | train went to the operating "B" train. The "B" train Chiller was tripped in | | error. The licensee informed the NRC resident inspector. | +------------------------------------------------------------------------------+
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021