Event Notification Report for October 31, 2000
U.S. Nuclear Regulatory Commission Operations Center Event Reports For 10/30/2000 - 10/31/2000 ** EVENT NUMBERS ** 37085 37394 37472 37473 37474 37475 +------------------------------------------------------------------------------+ |General Information or Other |Event Number: 37085 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: FLORIDA BUREAU OF RADIATION CONTROL |NOTIFICATION DATE: 06/15/2000| |LICENSEE: PROFESSIONAL SERVICE INDUSTRIES INC |NOTIFICATION TIME: 10:25[EDT]| | CITY: TAMPA REGION: 2 |EVENT DATE: 06/14/2000| | COUNTY: STATE: FL |EVENT TIME: 09:00[EDT]| |LICENSE#: 22-12 AGREEMENT: Y |LAST UPDATE DATE: 10/30/2000| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |RUDOLPH BERNHARD R2 | | | | +------------------------------------------------+ | | NRC NOTIFIED BY: CHARLES ADAMS (FACSIMILE) | | | HQ OPS OFFICER: BOB STRANSKY | | +------------------------------------------------+ | |EMERGENCY CLASS: N/A | | |10 CFR SECTION: | | |NAGR AGREEMENT STATE | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | AGREEMENT STATE REPORT | | | | The State of Florida Bureau of Radiation Control reported that a Troxler | | soil moisture/density gauge (Model 3430, Serial #30059), containing 8 mCi of | | Cs-137 and 40 mCi of Am-241/Be, had been stolen from a state licensee. The | | licensee reported that the gauge was stolen from a temporary job site | | between the hours of 6 p.m. on 6/13/00 and 9 a.m. on 6/14/00. The chain link | | fence surrounding the site was not damaged, but the door to the shed had | | been pried open. The lock on the storage locker containing the container and | | gauge had been cut. The gauge and container were the only items taken. The | | Hillsborough Sheriff's Office and the Florida Bureau of Radiation Control | | are investigating. The Sheriff's Office is planning to issue a press | | release. | | | | * * * UPDATE 1544 EST 10/30/2000 FROM ADAMS TAKEN BY STRANSKY * * * | | | | "Licensee reported that a gauge was stolen on June 14th. The gauge was found | | on October 30 at Veterans Memorial Park in Tampa. Item was found along a | | bike path. The gauge was slightly damaged, but the sources were intact | | locked in the gauge. Swipes showed no contamination. Item has been returned | | to owner." | | | | Notified R2DO (Boland). | +------------------------------------------------------------------------------+ !!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED !!!!!!! +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 37394 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: RIVER BEND REGION: 4 |NOTIFICATION DATE: 10/01/2000| | UNIT: [1] [] [] STATE: LA |NOTIFICATION TIME: 03:56[EDT]| | RXTYPE: [1] GE-6 |EVENT DATE: 09/30/2000| +------------------------------------------------+EVENT TIME: 23:33[CDT]| | NRC NOTIFIED BY: HUSTON |LAST UPDATE DATE: 10/30/2000| | HQ OPS OFFICER: CHAUNCEY GOULD +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |CHUCK CAIN R4 | |10 CFR SECTION: | | |AIND 50.72(b)(2)(iii)(D) ACCIDENT MITIGATION | | |NLCO TECH SPEC LCO A/S | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 100 Power Operation |100 Power Operation | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | PLANT ENTERED LCO ACTION STATEMENT WHEN BOTH PRIMARY CONTAINMENT UNIT | | COOLERS WHERE DECLARED INOPERABLE. | | | | On 09/30/00 at 2333, both Primary Containment Unit Coolers were declared | | inoperable based on an apparent failure to fully meet required volumetric | | flow rates. The Tech Spec SR 3.6.1.7.2 required values are greater than or | | equal to 50,000 CFM. Actual calculated values were determined to be | | approximately 45,000 CFM for Unit cooler A and 48,000 CFM for Unit cooler B. | | This condition may impact the ability of these unit coolers to perform their | | design safety functions. This report is being made pursuant to 10 CFR 50.72 | | b.2.iii.D for loss of function required to mitigate an accident. | | Activities to restore function include evaluation of test data and | | methodology, cleaning of unit cooler coils, verification of calibration | | data, and verification of system alignment. | | The plant is in a 8 hour LCO to restore one of the coolers to operable | | status or be in mode 3 within the following 12 hours. | | | | The NRC Resident Inspector was notified. | | | | * * * UPDATE ON 10/1/00 AT 2320 BY HUSTON, RECEIVED BY WEAVER * * * | | | | Both Primary Containment Unit Coolers A and B (Divisions I and II) have been | | re-tested satisfactorily verifying both safety function and Tech Spec | | operability. The station declared both Containment Unit Cooler A and B | | operable and exited the LCO regarding Primary Containment Unit Coolers at | | 1048 hours on 10/1/00 | | | | The station is evaluating information developed to determine whether a | | retraction is warranted. | | | | The licensee will notify the NRC resident inspector. The Operations Center | | notified the R4DO (Cain). | | | | * * * RETRACTION 2005 EST 10/30/2000 FROM CHASE TAKEN BY STRANSKY * * * | | | | "On September 30, 2000 at 2333, both primary containment unit coolers A and | | B were declared inoperable based on an apparent failure to meet required | | volumetric flow rates (50,000 CFM) as stated in Technical Specification | | Surveillance Requirement (SR) 3.6.1.7.2. This event was reported as a loss | | of function in accordance with 10CFR50.72 b.2.iii.D. | | | | "During Engineering evaluations of unit cooler condition, the surveillance | | test methodology was noted to contain a unit cooler face area that was | | smaller than the area depicted in the applicable design information. | | In-field measurements were taken on the unit coolers. These field | | measurements confirmed that a larger face area value should have been | | incorporated into the test methodology. Effectively, RBS had imposed a more | | conservative face area value resulting in lowering the as calculated flow | | rates that are used to determine acceptability. | | | | "Recalculation of the volumetric flow using the appropriate area resulted in | | the required Technical Specification SR 3.6.1.7.2 flow rate of 50,000 cubic | | feet per minute being achieved for primary containment unit cooler B. | | Therefore, primary containment unit cooler B was actually operable on | | September 30, 2000, at 2333 and at least one operable unit cooler was always | | maintained. Therefore, this issue was not reportable. | | | | "The coils of primary containment unit coolers A and B were also cleaned. | | Subsequently, using either the previous or recalculated value for the unit | | cooler face area, both unit coolers re-tested satisfactorily and were | | restored to service." | | | | The NRC resident inspector will be informed of this retraction by the | | licensee. Notified R4DO (Harrell). | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Other Nuclear Material |Event Number: 37472 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: PHILIP MORRIS USA |NOTIFICATION DATE: 10/30/2000| |LICENSEE: PHILIP MORRIS USA |NOTIFICATION TIME: 10:17[EST]| | CITY: RICHMOND REGION: 2 |EVENT DATE: 10/29/2000| | COUNTY: STATE: VA |EVENT TIME: 10:56[EST]| |LICENSE#: 45-00385-06 AGREEMENT: N |LAST UPDATE DATE: 10/30/2000| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |ANNE BOLAND R2 | | |DON COOL NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: CHUCK STIFF | | | HQ OPS OFFICER: DOUG WEAVER | | +------------------------------------------------+ | |EMERGENCY CLASS: N/A | | |10 CFR SECTION: | | |IBBF 30.50(b)(2)(ii) EQUIP DISABLED/FAILS | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | GAUGE SHUTTER FAILED TO CLOSE | | | | "On Sunday October 29, 2000, an Authorized User was conducting a routine, | | monthly radiation safety audit. The factory was running that weekend, but | | Bay 1 was shut down. At 10:56 a.m. he noticed the shutter indicator on | | maker 1B4 indicated the shutter was open. The maker at 1B4 is a Hauni | | Protos 100 (maker # 1004) with a Hauni weight control system and a Hauni SRM | | 8000 scanning head (gauge # 1319). This gauge has three Strontium 90 sealed | | sources for a combined strength of 0.025 curies. | | | | "The Authorized User inserted a cigarette rod in the pass tube to reduce the | | radiation level and called the Electrical Supervisor on duty. An Instrument | | Electrician (IE) was called to diagnose the weight control system. The IE | | found a defective circuit board. This Circuit board is located in the main | | electrical panel that controls the weight control system and the scanning | | head. The Authorized User stayed at the scanning head while the IE removed | | the defective circuit board and took it to the Electrical Repair Shop for | | repair. When the repaired circuit board was installed, the problem was | | fixed and the shutter closed properly. The Authorized User used the key | | switch to test the shutter several times and conducted a final survey with | | the shutter closed to ensure the shutter was closed and the scanning head | | was safe. The maker and scanning head were placed in service on C Shift, at | | approximately 11:00 p.m., October 29, 2000. The scanning head shutter would | | not open and the circuit board was removed and repaired again. The maker and | | scanning head were returned to service at approximately 6:30 a.m., October | | 30, 2000." | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 37473 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: HATCH REGION: 2 |NOTIFICATION DATE: 10/30/2000| | UNIT: [1] [] [] STATE: GA |NOTIFICATION TIME: 12:00[EST]| | RXTYPE: [1] GE-4,[2] GE-4 |EVENT DATE: 10/30/2000| +------------------------------------------------+EVENT TIME: 11:40[EST]| | NRC NOTIFIED BY: EDWEN URQUHART |LAST UPDATE DATE: 10/30/2000| | HQ OPS OFFICER: BOB STRANSKY +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |ANNE BOLAND R2 | |10 CFR SECTION: | | |DDDD 73.71 UNSPECIFIED PARAGRAPH | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N N 0 Cold Shutdown |0 Cold Shutdown | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | SECURITY REPORT | | | | Unescorted access granted inappropriately. Compensatory measures taken upon | | discovery. The NRC resident inspector has been informed of this event by the | | licensee. Contact the NRC Operations Center for additional details. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Fuel Cycle Facility |Event Number: 37474 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: PORTSMOUTH GASEOUS DIFFUSION PLANT |NOTIFICATION DATE: 10/30/2000| | RXTYPE: URANIUM ENRICHMENT FACILITY |NOTIFICATION TIME: 12:26[EST]| | COMMENTS: 2 DEMOCRACY CENTER |EVENT DATE: 10/29/2000| | 6903 ROCKLEDGE DRIVE |EVENT TIME: 19:54[EST]| | BETHESDA, MD 20817 (301)564-3200 |LAST UPDATE DATE: 10/30/2000| | CITY: PIKETON REGION: 3 +-----------------------------+ | COUNTY: PIKE STATE: OH |PERSON ORGANIZATION | |LICENSE#: GDP-2 AGREEMENT: N |DAVID HILLS R3 | | DOCKET: 0707002 |BRIAN SMITH NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: KEITH VANDERPOOL | | | HQ OPS OFFICER: BOB STRANSKY | | +------------------------------------------------+ | |EMERGENCY CLASS: N/A | | |10 CFR SECTION: | | |NCFR NON CFR REPORT REQMNT | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | 24-HOUR GASEOUS DIFFUSION PLANT REPORT | | | | "At approximately 1954 hours, 10/29/00, operations personnel investigated a | | LAW CADP smoke head alarm. While investigating the alarm for smoke head SXE | | 2786 for LAW 2A compressor the operations personnel did not identify any | | visible release but smelled HF in the area. The 'SEE & FLEE' emergency | | procedures were immediately implemented. The affected LAW station withdrawal | | loop was in standby at the time of the alarm. Results of all surveys | | performed during the emergency response were less than MDA. At 2102 hours an | | all clear was granted on the emergency response. PORTS is reporting this | | alarm as a valid actuation of a 'Q' Safety System. | | | | "This is reportable to the NRC as a valid actuation of a 'Q' Safety System | | in accordance with Safety Analysis Report, section 6.9 (24-HOUR REPORT)." | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 37475 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: PILGRIM REGION: 1 |NOTIFICATION DATE: 10/30/2000| | UNIT: [1] [] [] STATE: MA |NOTIFICATION TIME: 13:23[EST]| | RXTYPE: [1] GE-3 |EVENT DATE: 10/30/2000| +------------------------------------------------+EVENT TIME: 12:30[EST]| | NRC NOTIFIED BY: KEN GRACIA |LAST UPDATE DATE: 10/30/2000| | HQ OPS OFFICER: BOB STRANSKY +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |HAROLD GRAY R1 | |10 CFR SECTION: | | |AESS 50.72(b)(1)(v) EMERGENCY SIREN INOP | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 100 Power Operation |100 Power Operation | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | EMERGENCY SIRENS INOPERABLE DUE TO FAILURE OF RADIO REPEATERS | | | | The licensee reported that all offsite emergency sirens were inoperable | | during the period from 0150 10/29/00 through 0745 10/30/00 due to the | | failure of both radio repeaters. This condition was discovered during siren | | troubleshooting on 10/30/00. One of the repeaters has been restored to | | service. The NRC resident inspector will be informed of this event by the | | licensee. | +------------------------------------------------------------------------------+
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021