Skip to main content

The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.

Event Notification Report for October 12, 2000

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           10/11/2000 - 10/12/2000

                              ** EVENT NUMBERS **

37338  37422  

!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED  !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37338       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: VOGTLE                   REGION:  2  |NOTIFICATION DATE: 09/18/2000|
|    UNIT:  [1] [] []                 STATE:  GA |NOTIFICATION TIME: 06:16[EDT]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        09/18/2000|
+------------------------------------------------+EVENT TIME:        04:50[EDT]|
| NRC NOTIFIED BY:  KEITH POPE                   |LAST UPDATE DATE:  10/11/2000|
|  HQ OPS OFFICER:  DOUG WEAVER                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |STEPHEN CAHILL       R2      |
|10 CFR SECTION:                                 |                             |
|AIND 50.72(b)(2)(iii)(D) ACCIDENT MITIGATION    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          N       0        Cold Shutdown    |0        Cold Shutdown    |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| BOTH TRAINS OF RHR (RECIRC CAPABILITY) INOPERABLE FOR APPROXIMATELY SEVEN    |
| HOURS                                                                        |
|                                                                              |
| "While placing RHR Train 'B' in shutdown cooling during a refueling outage   |
| the pump minimum flow valve did not close as expected.   Investigation       |
| revealed that the mini-flow transmitter 1 FIS-0611 was isolated causing the  |
| valve 1 FV0611 to remain open with RHR flow in excess of setpoint that would |
| cause the valve to close.   Work was performed on August 29, 2000, to        |
| calibrate this transmitter.   On September 9, 2000,  RHR Train 'A' seal      |
| cooler was isolated for maintenance rendering both trains of RHR inoperable  |
| for 6 hours and 54 minutes.  The Cold leg injection capability from RHR      |
| Train 'A' remained available during this time. The Cold leg recirculation    |
| capability during these inoperabilities was not available.  This would have  |
| required entry into T. S. 3.0.3.                                             |
|                                                                              |
| "RHR Train 'B' mini-flow transmitter 1FIS-0611 was discovered isolated       |
| causing the valve 1FV0611 to remain open with RHR flow in excess of setpoint |
| that would cause the valve to close.  The transmitter has been returned to   |
| service and the valve 1 FV0611 is operating properly."                       |
|                                                                              |
| The licensee notified the NRC resident inspector.                            |
|                                                                              |
| * * * RETRACTED AT 1524 EDT ON 10/11/00 BY BILL DUNN TO FANGIE JONES * * *   |
|                                                                              |
| "This retracts the 9-18-2000 notification made per 10 CFR 50.72              |
| (b)(2)(iii)(D). That notification described an event where both trains of    |
| RHR were inoperable for 6 hours and 54 minutes when one train was in a       |
| system outage and the inservice train was found to be inoperable. Full flow  |
| to the RCS cold legs was apparently not available because it was determined  |
| that the inservice train's miniflow line valve would not close had a design  |
| basis accident occurred. Design engineering reviews have revealed that, with |
| the mini-flow valve open, the inservice RHR train remained capable of        |
| providing minimum flow to the RCS for analyzed accident scenarios.           |
| Therefore, because one train of RHR remained operable, a condition did not   |
| exist that would have prevented the fulfillment of a safety function needed  |
| to mitigate the consequences of an accident."                                |
|                                                                              |
| The licensee notified the NRC Resident Inspector.  The R2DO (Ken Barr) has   |
| been notified.                                                               |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Fuel Cycle Facility                              |Event Number:   37422       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: GLOBAL NUCLEAR FUEL - AMERICAS       |NOTIFICATION DATE: 10/11/2000|
|   RXTYPE: URANIUM FUEL FABRICATION             |NOTIFICATION TIME: 16:12[EDT]|
| COMMENTS: LEU CONVERSION (UF6 TO UO2)          |EVENT DATE:        10/10/2000|
|           LEU FABRICATION                      |EVENT TIME:        17:00[EDT]|
|           LWR COMMERICAL FUEL                  |LAST UPDATE DATE:  10/11/2000|
|    CITY:  WILMINGTON               REGION:  2  +-----------------------------+
|  COUNTY:  NEW HANOVER               STATE:  NC |PERSON          ORGANIZATION |
|LICENSE#:  SNM-1097              AGREEMENT:  Y  |KEN BARR             R2      |
|  DOCKET:  07001113                             |PATRICIA HOLAHAN     NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  LON PAULSON                  |                             |
|  HQ OPS OFFICER:  FANGIE JONES                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NBNL                     RESPONSE-BULLETIN      |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| 24-HOUR NRC BULLETIN 91-01 REPORT                                            |
|                                                                              |
| "At approximately 1700 hours on October 10, 2000 GNF-A Operations determined |
| that one of two controls established for moderation control on material feed |
| to a process area located within an Moderation Restricted Area (MRA) had     |
| been lost. The controls require two samples that verify acceptable moisture  |
| content for the feed material. One of two required moisture samples was not  |
| analyzed due to an inadvertent purge of the moisture sample request from the |
| IMR (In-process Material Release) database, and the material was improperly  |
| released for processing.                                                     |
|                                                                              |
| "The second independent moisture sample was performed and confirmed the      |
| measured moisture content was satisfactory, therefore no unsafe condition    |
| existed.                                                                     |
|                                                                              |
| "This event is reported pursuant to NRC Bulletin 91-01 (within 24 hours) due |
| to loss of a single control on moderation. Material can feed to affected     |
| moderation restricted area (MRA) of process have been suspended pending      |
| investigation and implementation of corrective actions.                      |
|                                                                              |
| "SAFETY SIGNIFICANCE OF EVENTS:  Low safety significance - independent       |
| control on moderation remained intact; material met moisture                 |
| specifications.                                                              |
|                                                                              |
| "POTENTIAL CRITICALITY PATHWAYS INVOLVED:  Multiple failure modes required   |
| before a criticality accident could occur.                                   |
|                                                                              |
| "CONTROLLED PARAMETER(S)  (MASS, MODERATION , GEOMETRY, CONCENTRATION,       |
| ETC.):  Moderation:  Process equipment limited to uniform moisture content   |
| of 10.5 wt. % (105,000 ppm H2O).  Moderation Safety Factor = safety          |
| moderation limit / process moderation limit = 105,000 / 4000 = 26.2.         |
|                                                                              |
| "ESTIMATED AMOUNT, ENRICHMENT, FORM OF LICENSED MATERIAL (INCLUDE PROCESS    |
| LIMIT AND % WORST BASE CRITICAL MASS):  Affected equipment contained         |
| approximately 100 kgs of UO2 and gadolinia (Gd2O3) at a target enrichment of |
| ~4.40 wt. % U235.  The vibromill blender process equipment is located in the |
| moderation-restricted area, which is demonstrated safe for uniform           |
| moderation limit of 10.5 % water equivalent moderation (105,000 ppm H2O).    |
|                                                                              |
| "NUCLEAR CRITICALITY SAFETY CONTROL(S) OR CONTROL SYSTEM(S) AND DESCRIPTION  |
| OF THE FAILURES OR DEFICIENCIES:  One of two required moisture samples was   |
| not analyzed due to an inadvertent purge of the moisture sample request from |
| the IMR (In-process Material Release) database, and the material was         |
| improperly released for processing in the gad shop MRA.                      |
|                                                                              |
| "CORRECTIVE ACTIONS TO RESTORE SAFETY SYSTEMS AND WHEN EACH WAS IMPLEMENTED: |
| 1. Feed material re-sampled for moisture content - results satisfactory      |
| (<4000 ppm H2O).  2. Suspended material can feed to the affected process     |
| area.  3. Investigation and implementation of corrective actions pending."   |
|                                                                              |
| The licensee intends to notify the NRC Region 2 (David Ayres), the New       |
| Hanover County and North Carolina State agencies of this event.              |
+------------------------------------------------------------------------------+


Page Last Reviewed/Updated Thursday, March 25, 2021

Page Last Reviewed/Updated Thursday, March 25, 2021