The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.
Event Notification Report for October 10, 2000
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
10/06/2000 - 10/10/2000
** EVENT NUMBERS **
37305 37414 37415 37416 37417 37418 37419
!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37305 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: FITZPATRICK REGION: 1 |NOTIFICATION DATE: 09/11/2000|
| UNIT: [1] [] [] STATE: NY |NOTIFICATION TIME: 12:42[EDT]|
| RXTYPE: [1] GE-4 |EVENT DATE: 09/11/2000|
+------------------------------------------------+EVENT TIME: 11:45[EDT]|
| NRC NOTIFIED BY: MARK ABRAMSKI |LAST UPDATE DATE: 10/06/2000|
| HQ OPS OFFICER: DOUG WEAVER +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |JAMES TRAPP R1 |
|10 CFR SECTION: | |
|AOUT 50.72(b)(1)(ii)(B) OUTSIDE DESIGN BASIS | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| OUTSIDE DESIGN BASIS - STATION BATTERY CALCULATIONS |
| |
| An engineering review of voltage drop calculations for station battery |
| systems (A & B) has identified an error in the assumed value for the current |
| rating for the starting coil on the A & B ESW pump motor starter. The |
| starting coil is actually rated for 44 amps vs. 6 amps as originally |
| assumed. This discrepancy results in a calculated terminal voltage at the |
| coil below that stated on the name plate. This condition is considered to |
| be outside the design basis of the plant. |
| |
| The licensee notified the NRC resident inspector. |
| |
| * * * RETRACTION on 10/06/00 at 1059 ET by Abramski taken by MacKinnon * * |
| * |
| |
| Subsequent testing has determined that there would in fact be sufficient |
| terminal voltage at the starting coil of the A & B ESW Pump motor starters |
| during a postulated Loss of Offsite Power. Therefore the plant was not |
| outside its design basis and this event is being retracted. R1DO (Linville) |
| notified |
| |
| The NRC Resident Inspector was notified of this retraction by the licensee. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37414 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SAINT LUCIE REGION: 2 |NOTIFICATION DATE: 10/06/2000|
| UNIT: [1] [2] [] STATE: FL |NOTIFICATION TIME: 09:47[EDT]|
| RXTYPE: [1] CE,[2] CE |EVENT DATE: 10/06/2000|
+------------------------------------------------+EVENT TIME: 09:20[EDT]|
| NRC NOTIFIED BY: DAVE WILLIAMS |LAST UPDATE DATE: 10/06/2000|
| HQ OPS OFFICER: DOUG WEAVER +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |LEONARD WERT R2 |
|10 CFR SECTION: | |
|APRE 50.72(b)(2)(vi) OFFSITE NOTIFICATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
|2 N Y 100 Power Operation |100 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION - |
| |
| THE LICENSEE NOTIFIED THE FLORIDA FISH & WILDLIFE CONSERVATION COMMISSION |
| ABOUT A LIVE LOGGERHEAD SEA TURTLE THAT WAS FOUND IN THE INTAKE NET. THE |
| TURTLE WILL BE SENT OFF FOR REHABILITATION. |
| |
| THE LICENSEE NOTIFIED THE NRC RESIDENT INSPECTOR. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 37415 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: WA DIVISION OF RADIATION PROTECTION |NOTIFICATION DATE: 10/06/2000|
|LICENSEE: TRANSALTA CENTRALIA MINING, LLC |NOTIFICATION TIME: 19:45[EDT]|
| CITY: CENTRALIA REGION: 4 |EVENT DATE: 10/05/2000|
| COUNTY: STATE: WA |EVENT TIME: [PDT]|
|LICENSE#: WN-I0241-1 AGREEMENT: Y |LAST UPDATE DATE: 10/06/2000|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |DAVE LOVELESS R4 |
| |M. WAYNE HODGES NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: TERRY FRAZEE (EMAIL) | |
| HQ OPS OFFICER: STEVE SANDIN | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|NAGR AGREEMENT STATE | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT - SOURCE DETACHED FROM DRIVE ROD |
| |
| "The licensee notified the WA Department of Health, Division of Radiation |
| Protection (WDOH), of an additional mechanical failure involving the same |
| Ronan Engineering Company Model SA-4 gauging device which suffered |
| a 'source disconnect' as reported in event #WA-00-046. The device is |
| specifically licensed for density process measurements and uses a Cesium 137 |
| sealed source, Amersham Model CDC.711M not to exceed 74 gigabecquerels (2 |
| curies). The source is normally mounted at the end of a source rod, |
| approximately six feet long. In this particular model version, the source |
| rod consists of two screw-together extensions (approximately two and a half |
| feet each) which screw into the same diameter source holder (approximately |
| half a foot long). When operating, the rod with source is lowered through |
| the shielded storage position, into the integral and enclosed dry well tube. |
| When not in operation, the rod with source is raised to place the source |
| into a safe position inside the main shielding. On September 13, the top |
| screw connection came unscrewed apparently due to prolonged mechanical |
| vibration. This 'disconnect' was repaired and the gauge returned to |
| operation on September 18. At the same time the lower screw connection was |
| found to be partially unscrewed as well. Both connections were opened, |
| cleaned, coated with 'Lok-tite' and tightened. |
| |
| "On October 5, during routine 'end of shift' return of the source to the |
| shielded position, the source rod snapped off at the lower screw connection. |
| The operator was able to quickly grab the exposed end of the source holder |
| and prevent the source from falling to the bottom of the dry well. The |
| source was successfully locked out in the shielded storage position. |
| Examination of the source rod indicates that the male screw connector |
| sheared off at its juncture with the main body of the rod section. The |
| cause of this additional failure is under investigation. The manufacturer |
| is working on a retrofit for all four gauges of this type at this licensee's |
| facility. Department staff will be present during the retrofit." |
| |
| HOO NOTE: See event #37353 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37416 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: WATTS BAR REGION: 2 |NOTIFICATION DATE: 10/06/2000|
| UNIT: [1] [] [] STATE: TN |NOTIFICATION TIME: 21:19[EDT]|
| RXTYPE: [1] W-4-LP,[2] W-4-LP |EVENT DATE: 10/06/2000|
+------------------------------------------------+EVENT TIME: 19:39[EDT]|
| NRC NOTIFIED BY: BENJAMIN HUNT |LAST UPDATE DATE: 10/06/2000|
| HQ OPS OFFICER: STEVE SANDIN +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |LEONARD WERT R2 |
|10 CFR SECTION: | |
|AESF 50.72(b)(2)(ii) ESF ACTUATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 13 Power Operation |13 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| AUTOSTART OF AUXILIARY FEEDWATER PUMPS WHILE PREPARING TO ROLL THE MAIN |
| TURBINE |
| |
| "At 1939 hours on 10/6/2000, with the reactor in mode 1 at 13 % power, |
| preparations to roll the Main Turbine for Main Turbine testing, the 'B' Main |
| Feedwater Pump tripped on low condenser vacuum. 'A' Main Feedwater Pump was |
| not in service, and 'B' Main Feedwater Pump was supplying all Steam |
| Generators. |
| |
| "Off Normal Instruction (AOI-16) was entered and the Standby Main Feedwater |
| Pump was started to supply all Steam Generators, the reactor was maintained |
| at 13 % power. All Auxiliary Feedwater Pumps started upon receipt of the ESF |
| signal (loss of both Main Feedwater Pumps). |
| |
| "This is Reportable event under 10 CFR 50.72(b)(2)(ii) and 50.73(a)(2)(iv), |
| any event or condition that results in a manual or automatic actuation of |
| any engineered safety feature (ESF)." |
| |
| The licensee informed the NRC resident inspector. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Fuel Cycle Facility |Event Number: 37417 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PADUCAH GASEOUS DIFFUSION PLANT |NOTIFICATION DATE: 10/08/2000|
| RXTYPE: URANIUM ENRICHMENT FACILITY |NOTIFICATION TIME: 17:59[EDT]|
| COMMENTS: 2 DEMOCRACY CENTER |EVENT DATE: 10/08/2000|
| 6903 ROCKLEDGE DRIVE |EVENT TIME: 05:18[CDT]|
| BETHESDA, MD 20817 (301)564-3200 |LAST UPDATE DATE: 10/08/2000|
| CITY: PADUCAH REGION: 3 +-----------------------------+
| COUNTY: McCRACKEN STATE: KY |PERSON ORGANIZATION |
|LICENSE#: GDP-1 AGREEMENT: Y |JOHN MADERA R3 |
| DOCKET: 0707001 |M. WAYNE HODGES NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: J.M. UNDERWOOD | |
| HQ OPS OFFICER: STEVE SANDIN | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|NCFR NON CFR REPORT REQMNT | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| 24-HOUR REPORT INVOLVING A SAFETY SYSTEM ACTUATION DUE TO FAILURE OF |
| FREEZER/SUBLIMER INLET VALVE TO CLOSE |
| |
| "At 0518 on 10/8/00 the PSS office was notified that the C-333 Unit 4 Cell 9 |
| freezer/sublimer (F/S) 'B' valve had failed to close following completion of |
| a high-high weight safety system trip test. The F/S high-high weight trip |
| actuated due to accumulation of UF6 in the vessel caused by the failure of |
| the 'B' valve. The F/S high-high weight trip system is required to be |
| operable while in modes F/S 1 and F/S 3 per TSR 2.4.3.1. The F/S high-high |
| weight trip actuated within the specified limiting control settings of TSR |
| 2.4.3.1. The F/S 'B' valve was manually closed, the F/S was declared |
| inoperable and the excess UF6 was removed from the vessel. The F/S was |
| placed in mode F/S 6 (out of service). |
| |
| "The safety system actuation is reportable to the NRC as required by Safety |
| Analysis Report section 6.9, table 1, criteria J.2, Safety System actuation |
| due to a valid signal as a 24-hour event notification. |
| |
| "The NRC Resident inspector has been notified of this event." |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37418 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: HOPE CREEK REGION: 1 |NOTIFICATION DATE: 10/08/2000|
| UNIT: [1] [] [] STATE: NJ |NOTIFICATION TIME: 18:11[EDT]|
| RXTYPE: [1] GE-4 |EVENT DATE: 10/08/2000|
+------------------------------------------------+EVENT TIME: 16:20[EDT]|
| NRC NOTIFIED BY: DAN BOYLE |LAST UPDATE DATE: 10/08/2000|
| HQ OPS OFFICER: STEVE SANDIN +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |JAMES LINVILLE R1 |
|10 CFR SECTION: | |
|AIND 50.72(b)(2)(iii)(D) ACCIDENT MITIGATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 99 Power Operation |99 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| "B" REACTOR RECIRC PUMP MOTOR GENERATOR OVERSPEED STOPS FOUND SET HIGH |
| (NON-CONSERVATIVE) DURING SURVEILLANCE TESTING |
| |
| "During the performance of the 18 month surveillance requirement to |
| demonstrate operability of the reactor recirc pump motor set scoop tube |
| mechanical and electrical stop overspeed setpoints to be less than or equal |
| to 109% and 107%, respectively, the 'B' MG set stops were found |
| non-conservatively high. The magnitude of offset has not been calculated as |
| of this time, but the setpoints have been readjusted to their proper |
| settings as of 1732 hours this date. |
| |
| "The potential impact of this condition would be a function of the reactor |
| recirc pump 'runaway' transient. If that analyzed transient were to have |
| occurred, the potential existed for the flow dependent minimum critical |
| power ratio to have been exceeded. This could result in exceeding the |
| safety limit (MCPR) under those postulated conditions. |
| |
| "Evaluation of the potential cause of the improper settings is under way." |
| |
| The licensee will inform the NRC resident inspector and the Lower Alloways |
| Creek Township. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37419 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SALEM REGION: 1 |NOTIFICATION DATE: 10/09/2000|
| UNIT: [1] [] [] STATE: NJ |NOTIFICATION TIME: 01:03[EDT]|
| RXTYPE: [1] W-4-LP,[2] W-4-LP |EVENT DATE: 10/09/2000|
+------------------------------------------------+EVENT TIME: 00:42[EDT]|
| NRC NOTIFIED BY: TIM PRZEKOP |LAST UPDATE DATE: 10/09/2000|
| HQ OPS OFFICER: JOHN MacKINNON +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: UNU |JAMES LINVILLE R1 |
|10 CFR SECTION: |CHRISTOPHER GRIMES NRR |
|AAEC |CHARLES MILLER IRO |
| |CANUPP FEMA |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| HYDRAZINE LEAK IN TURBINE BUILDING. |
| |
| Salem Unit 1 declared an Unusual Event at 0042 based on ammonia smell in |
| Unit 1 Turbine Building. Area was evacuated - no personnel were working in |
| the area. It appears as though hydrazine leaked from a chemical addition |
| tank due to a failure of a chemical transfer pump. Loss prevention |
| personnel verified no one in area. Air samples all less than 1ppm |
| hydrazine. Odor is dissipating. Abnormal Operating Procedure for Toxic Gas |
| Release has been implemented and Control Room Ventilation placed in Fire |
| Outside Control Room Alignment. Unit 1 remained at 100%. No safeguards |
| activated or needed. All safeguards equipment is available . Hydrazine |
| was contained in a dike and directed to chemical waste. Air sampling will |
| continue until spill is cleaned up and no odor remains. State and local |
| Counties notified. |
| |
| The NRC Resident Inspector will be notified of this event by the licensee. |
| |
| * * * Update on 10/09/00 at 0502 ET by Przekop taken by MacKinnon * * * |
| |
| Unusual Event terminated at 0500 ET. All hydrazine was cleaned up (25 to 50 |
| gallons). State & local counties will be notified by the licensee. R1DO |
| (Linville), NRR EO (Grimes), IRO (Miller), & FEMA (Canupp) notified. DOE, |
| USDA, HHS and DOT(EPA) notified via fax. |
| |
| The NRC Resident Inspector will be notified by the licensee of the |
| termination of the Unusual Event. |
+------------------------------------------------------------------------------+
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021