The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.
Event Notification Report for October 4, 2000
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
10/03/2000 - 10/04/2000
** EVENT NUMBERS **
37330 37402 37403 37404 37405 37406 37407
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37330 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PEACH BOTTOM REGION: 1 |NOTIFICATION DATE: 09/15/2000|
| UNIT: [2] [] [] STATE: PA |NOTIFICATION TIME: 17:57[EDT]|
| RXTYPE: [2] GE-4,[3] GE-4 |EVENT DATE: 09/15/2000|
+------------------------------------------------+EVENT TIME: 15:05[EDT]|
| NRC NOTIFIED BY: JESSE JAMES |LAST UPDATE DATE: 10/03/2000|
| HQ OPS OFFICER: JOHN MacKINNON +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |JAMES TRAPP R1 |
|10 CFR SECTION: | |
|ARPS 50.72(b)(2)(ii) RPS ACTUATION | |
|AESF 50.72(b)(2)(ii) ESF ACTUATION | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|2 M/R Y 15 Power Operation |0 Hot Shutdown |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| MANUALLY SCRAMMED THE REACTOR AFTER ENTERING THE RESTRICTIVE AREA OF THE |
| POWER TO FLOW MAP. |
| |
| On September 15, 2000 at Peach Bottom Atomic Power Station (PBAPS), Unit 2 |
| was manually scrammed per operating procedure during turbine testing in |
| preparation for the refuel outage. |
| |
| The manual scram was due to entering restricted area of the power to flow |
| map from Technical Specification 3.4.1, after the trip of the "2B" |
| recirculation pump. All rods fully inserted and the reactor was shutdown. |
| Reactor level during the scram lowered to 0" and a Group II and III primary |
| and secondary containment isolation was received. The isolations functioned |
| as designed. The plant is stable in hot shutdown with the main condenser as |
| a heat sink and the feedwater system is in service for level control. No |
| radioactive release or Emergency Core Cooling System injection occurred |
| during the scram. |
| |
| The turbine was tripped in accordance with the refuel outage plan when the |
| recirculation pump tripped. The plan was to perform turbine testing and |
| then to manually scram the reactor at the same power level. |
| |
| The reactor was manually scrammed less than one minute after entering the |
| restricted area of the power to flow map. No power oscillations were seen. |
| |
| The NRC Resident Inspector was notified of this event by the licensee. |
| |
| * * * RETRACTED AT 1715 EDT ON 9/21/00 BY ANDREW WINTER TO FANGIE JONES * * |
| * |
| |
| "On September 15, 2000 PBAPS reported that Unit 2 was manually scrammed in |
| accordance with operating instructions during turbine testing. The report |
| identified that the manual scram was initiated based on entering the |
| restricted area of the power to flow map after the tripping of the 2B |
| Recirculation Pump. This notification is being retracted based on the |
| following: |
| |
| "NUREG 1022 Revision 1 specifically states that 'The Commission is |
| interested both in events where an ESF was needed to mitigate the |
| consequences (whether or not the equipment performed properly) and events |
| where an ESF actuated unnecessarily....This indicates an intent to require |
| reporting actuations of features that mitigate the consequences of |
| significant events.' Therefore, the following is an analysis of these two |
| underlying reasons for reporting ESF actuations: |
| |
| 1. The need for the ESF to mitigate the consequences of an event: |
| |
| The September 15, 2000 PBAPS manual scram was initiated because the plant |
| operator made a conservative decision in accordance with station procedures |
| to initiate a reactor scram. At the time this decision was made, the plant |
| conditions were approximately 16 percent power and 24 percent core flow. |
| Although this condition is close to an operational limit conservatively |
| established by the licensee and the operator made the correct decision to |
| commence the plant shutdown, the ESF actuation was not necessary to mitigate |
| the consequences of this evolution. Moreover, plant conditions were not |
| changing in a direction that would have required the manual scram to |
| mitigate the consequences of significant events. |
| |
| 2. Events where an ESF actuated unnecessarily: |
| |
| The actuation of a manual scram and the subsequent PCIS Group II and Ill |
| actuations were part of a preplanned shutdown for the commencement of the |
| PBAPS Unit 2's thirteenth refueling outage (2R13) and were necessary to |
| complete the plant shutdown. The decision to insert the manual scram in |
| accordance with station procedures, resulted in the preplanned shutdown |
| commencing slightly early. Therefore, the ESP did not actuate unnecessarily |
| since it was already planned to shutdown the plant by inserting a manual |
| scram. |
| |
| "Therefore, based on the above discussion, this event is not reportable |
| because the manual scram resulted from and was, in accordance with the |
| licensee's procedure, and part of a preplanned sequence of reactor |
| operation." |
| |
| The licensee notified the NRC Resident Inspector. The R1DO (William Ruland) |
| has been notified. |
| |
| ***** UPDATE AT 1554 ON 10/03/00 FROM ANDREW WINTER TO LEIGH TROCINE ***** |
| |
| Via this update, the licensee is resubmitting this event notification |
| because the event was determined to represent an unplanned ESF actuation. |
| The licensee is also providing additional clarification to the original |
| report because it was determined that the unit was not operating in an |
| unrestricted region of the technical specifications. |
| |
| The following text is a portion of a facsimile received from the licensee: |
| |
| "On September 23, 2000, PBAPS submitted a retraction to Event #37330. After |
| further review, it was determined that the basis for the PBAPS retraction |
| was not consistent with the NRC interpretation of the reporting requirement. |
| Therefore, the following event report is being resubmitted:" |
| |
| "On September 15, 2000, PBAPS Unit 2 was manually scrammed. The manual |
| reactor scram was initiated by the plant operator based on the understanding |
| that the plant conditions placed the plant in the restricted area of the |
| power-to-flow map after the unplanned tripping of the 2B Reactor |
| Recirculation Pump. The plant conditions at the time of the manual scram |
| were approximately 16 percent power and 24 percent core flow. Although this |
| condition is close to an operational limit conservatively established by the |
| licensee to commence the plant shutdown, the ESF actuation was not necessary |
| to mitigate the consequences of this evolution. Furthermore, the plant was |
| not in an unrestricted region of Technical Specification 3.4.1, and |
| emergency systems subsequently performed as required." |
| |
| "Although the ESF actuation was not necessary to mitigate an event, it is |
| the conclusion of the licensee that this event does represent an unplanned |
| ESF actuation. Therefore, this event is reportable under 10 CFR |
| 50.72(b)(2)(ii)." |
| |
| The licensee notified the NRC resident inspector and plans to submit a |
| Licensee Event Report by 10/15/00. The NRC operations officer notified the |
| R1DO (Linville). |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37402 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: MAINE YANKEE REGION: 1 |NOTIFICATION DATE: 10/03/2000|
| UNIT: [1] [] [] STATE: ME |NOTIFICATION TIME: 13:16[EDT]|
| RXTYPE: [1] CE |EVENT DATE: 10/03/2000|
+------------------------------------------------+EVENT TIME: 12:50[EDT]|
| NRC NOTIFIED BY: MIKE GABRIELE |LAST UPDATE DATE: 10/03/2000|
| HQ OPS OFFICER: LEIGH TROCINE +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |JAMES LINVILLE R1 |
|10 CFR SECTION: |facsimile to HQs PAO |
|APRE 50.72(b)(2)(vi) OFFSITE NOTIFICATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N N 0 Decommissioned |0 Decommissioned |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| ISSUANCE OF A PRESS RELEASE REGARDING A TEMPORARY WORK STOPPAGE ON MOST |
| PLANT DISMANTLEMENT ACTIVITIES FOLLOWING A CONTAMINATION INCIDENT |
| |
| At 1250 on 10/03/00, the licensee issued a press release regarding an |
| incident that occurred on 09/29/00. The following text is a portion of a |
| this press release: |
| |
| "Maine Yankee has temporarily halted work on most plant dismantlement |
| activities following an incident last Friday [09/29/00] where the clothing |
| of 4 workers was slightly contaminated with radiological material. The |
| workers were welding shielding plates in 2 waste shipping containers on the |
| non-nuclear side of the plant. The shipping containers previously had been |
| mistakenly released from the nuclear side of the facility. There was no |
| measurable internal dose to the workers or skin contamination from the |
| incident. The radiological dose to the exposed workers was less than one |
| millirem. In Maine, the annual radiological dose an individual receives |
| from all sources, natural and manmade, is about 350 millirem." |
| |
| "The clothing contamination was discovered early Saturday morning when one |
| of the workers who had been sent to perform a task on the nuclear side of |
| the plant alarmed a radiation monitor when exiting. Technicians identified |
| the shipping containers as the source of the contamination and evaluated 3 |
| other workers who had been working on the containers. No contamination was |
| found on the clothing of these individuals. Maine Yankee also followed up |
| with another ten workers who worked on the containers during the day shift |
| Friday to determine whether there were any additional articles of |
| contaminated clothing. Three of these individuals were found to have |
| slightly contaminated clothing. As a precautionary measure, Maine Yankee is |
| surveying the homes and vehicles of the affected workers. No additional |
| contamination has been identified." |
| |
| "An analysis is underway to determine specifically how the contaminated |
| containers were released to the non-nuclear side of the plant. Radiological |
| work will only resume when Maine Yankee's senior management is convinced |
| work control procedures are appropriate and are being implemented thoroughly |
| and completely. Maine Yankee has discussed this incident and our response |
| with the U.S. Nuclear Regulatory Commission and the State of Maine." |
| |
| " 'Controlling radiological material is fundamental to the success of the |
| decommissioning project. That is why, even though there is no health |
| concern as a result of this incident, we stopped plant dismantlement |
| activities until we have convinced ourselves that we are ready to return to |
| work,' said Mike Meisner, Maine Yankee President. Meisner added, 'I am |
| pleased, however, that redundant controls and processes we have in place as |
| well as our professional staff helped us identify the problem and react |
| appropriately.' " |
| |
| The licensee notified an onsite NRC inspector. (Call the NRC operations |
| officer for a licensee contact name and telephone number.) |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37403 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SAINT LUCIE REGION: 2 |NOTIFICATION DATE: 10/03/2000|
| UNIT: [] [2] [] STATE: FL |NOTIFICATION TIME: 16:05[EDT]|
| RXTYPE: [1] CE,[2] CE |EVENT DATE: 10/03/2000|
+------------------------------------------------+EVENT TIME: 15:22[EDT]|
| NRC NOTIFIED BY: STEVE MERRILL |LAST UPDATE DATE: 10/03/2000|
| HQ OPS OFFICER: LEIGH TROCINE +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |LEONARD WERT R2 |
|10 CFR SECTION: |CHRISTOPHER GRIMES NRR |
|NLTR LICENSEE 24 HR REPORT |CHARLES MILLER IRO |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
| | |
|2 N Y 100 Power Operation |100 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| DISCOVERY THAT REACTOR POWER EXCEEDED 100% FOR A PERIOD OF GREATER THAT 8 |
| HOURS DUE TO AN INSTRUMENT FAILURE ON THE LEADING EDGE FLOW METER |
| |
| The following text is a portion of a facsimile received from the licensee: |
| |
| "St. Lucie Unit 2 average power level was calculated to have been 100.1% |
| power for greater than 8 hours on September 25, 2000. This power level |
| resulted from an instrumentation failure on the Leading Edge Flow Meter |
| (LEFM) which was utilized by the [Digital Data Processing System (DDPS)] |
| Plant Computer Calorimetric power level indication. A failure in the DP1 |
| transducer path on the 'A' Loop of the LEFM instrument resulted in a |
| decreasing feedwater (FW) flow output value." |
| |
| "Detailed analysis of the plant's performance over September 24, 2000, and |
| September 25, 2000, indicate an unexpected decrease in 'A' LEFM Feedwater |
| Flow indicated to the DDPS beginning approximately mid-day on September 24, |
| 2000, without a corresponding decrease in 'A' Venturi based Feedwater Flow. |
| A direct and corresponding decrease in DDPS Calorimetric Power results from |
| the 'A' LEFM FW Flow decrease. A corresponding decrease in 'B' side LEFM or |
| Venturi FW Flow was not present. This confirmed the Vendor's initial report |
| of an 'A' side instrumentation problem within the LEFM System. The |
| Operations Crew questioned this decrease and initiated conservative action |
| as a result of DDPS Calorimetric Power observed to be lowering. Prior to |
| and during the LEFM instrument failure, the indicated Calorimetric Power |
| level in use by the plant operators did not exceed 100.0% for greater than 8 |
| hours. The LEFM transducer was repaired and returned to service [on] |
| October 1, 2000." |
| |
| "Based upon subsequent analysis of 'B' side LEFM FW Flow and 'A' [and] 'B' |
| side Venturi FW Flow, the change in power was approximately 0.2% reactor |
| power. The maximum power level was approximately 99.9% on September 24, |
| 2000, and approximately 100.1% (with a maximum of 100.2%) power on September |
| 25, 2000. An increase to 100.2% is well within the uncertainty for DDPS |
| Calorimetric Power of 1.3% and initial power assumed within the Safety |
| Analysis of 2%." |
| |
| "This event was determined to be reportable at 15:22 on October 3, 2000, in |
| accordance with St. Lucie Unit 2 Operating License condition 2.F: Operation |
| of St. Lucie Unit 2 in excess of 100% power for greater than 8 hours is in |
| excess of the plant's Operating License limit of 'not in excess of 2700 |
| megawatts thermal (100% power).' The Unit 2 License requires that [the |
| licensee] 'shall report any violations of these requirements within 24 hours |
| by telephone and confirm by telegram, mailgram, or facsimile transmission to |
| the NRC Regional Administrator, Region II, or his designee, no later than |
| the first working day following the violation, with a written follow-up |
| report with 14 days.' " |
| |
| The licensee notified the NRC resident inspector. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 37404 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: CALIFORNIA RADIATION CONTROL PRGM |NOTIFICATION DATE: 10/03/2000|
|LICENSEE: ADAC LABORATORIES |NOTIFICATION TIME: 16:17[EDT]|
| CITY: MILPITAS REGION: 4 |EVENT DATE: 10/02/2000|
| COUNTY: STATE: CA |EVENT TIME: 10:00[PDT]|
|LICENSE#: 2760-43 AGREEMENT: Y |LAST UPDATE DATE: 10/03/2000|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |DAVE LOVELESS R4 |
| |M. WAYNE HODGES NMSS |
+------------------------------------------------+CHARLES MILLER IRO |
| NRC NOTIFIED BY: KENT PRENDERGAST | |
| HQ OPS OFFICER: LEIGH TROCINE | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|NAGR AGREEMENT STATE | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT REGARDING THE LOSS OF FIVE SEALED SOURCES AT ADAC |
| LABORATORIES IN MILPITAS, CALIFORNIA |
| |
| Adac Laboratories (State license #2760-43) in Milpitas, California, |
| manufactures nuclear medicine equipment and utilizes sealed sources for |
| testing cameras, etc. The sources are stored in a depleted uranium storage |
| container. |
| |
| On 09/26/00, Adac Laboratories performed an audit, and the location of five |
| sealed sources could not be determined (one 28.5 mCi cesium-137 source and |
| four gadolinium-153 sources with activities of 14.2 mCi, 0.87 mCi, 0.2 mCi, |
| and 0.15 mCi). Adac Laboratories has taken action to secure that remaining |
| sources and is making efforts to locate the missing sources. |
| |
| The licensee notified the State of California at approximately 1000 PDT on |
| 10/02/00, and a representative from the State of California Radiologic |
| Health Branch (Kent Prendergast) in turn notified the NRC Operations Center |
| of the loss of five sealed sources at 1617 on 10/03/00. |
| |
| (Call the NRC operations officer for a State contact telephone number, |
| licensee address, and licensee radiation safety officer name.) |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Fuel Cycle Facility |Event Number: 37405 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PORTSMOUTH GASEOUS DIFFUSION PLANT |NOTIFICATION DATE: 10/03/2000|
| RXTYPE: URANIUM ENRICHMENT FACILITY |NOTIFICATION TIME: 17:39[EDT]|
| COMMENTS: 2 DEMOCRACY CENTER |EVENT DATE: 10/03/2000|
| 6903 ROCKLEDGE DRIVE |EVENT TIME: 08:35[EDT]|
| BETHESDA, MD 20817 (301)564-3200 |LAST UPDATE DATE: 10/03/2000|
| CITY: PIKETON REGION: 3 +-----------------------------+
| COUNTY: PIKE STATE: OH |PERSON ORGANIZATION |
|LICENSE#: GDP-2 AGREEMENT: N |JOHN MADERA R3 |
| DOCKET: 0707002 |M. WAYNE HODGES NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: RICK LARSON | |
| HQ OPS OFFICER: LEIGH TROCINE | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|OCBB 76.120(c)(2)(ii) EQUIP DISABLED/FAILS | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| DISCOVERY THAT AN AUTOMATIC SHUTDOWN OF AN AUTOCLAVE ON 09/26/00 WAS A VALID |
| SAFETY SYSTEM ACTIVATION (24-hour report) |
| |
| The following text is a portion of a facsimile received from Portsmouth |
| personnel: |
| |
| "At 0835 [hours] on 10/03/00, the Plant Shift Superintendent was informed by |
| the Autoclave System Engineer that a Safety System actuation that occurred |
| on 09/29/00 was a valid event. At the time of the event, all indications |
| available to the operators indicated an invalid activation. The autoclave |
| was declared inoperable, and testing of the instruments for as-found |
| readings was performed. After obtaining the as-found readings on the |
| instrument loops, additional testing was conducted during the evening of |
| 10/02/00. This steam load testing allowed the pressure to reach the trip |
| point assigned value for shell high steam shutdown. Based on this |
| information, we are reporting an actuation of a safety system. There was no |
| release of radioactive material from this event." |
| |
| Portsmouth personnel notified the NRC resident inspector as well as the |
| Department of Energy site representative. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|General Information or Other |Event Number: 37406 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: CALIFORNIA RADIATION CONTROL PRGM |NOTIFICATION DATE: 10/03/2000|
|LICENSEE: UNKNOWN |NOTIFICATION TIME: 17:56[EDT]|
| CITY: SAN JOSE REGION: 4 |EVENT DATE: 10/03/2000|
| COUNTY: STATE: CA |EVENT TIME: [PDT]|
|LICENSE#: AGREEMENT: Y |LAST UPDATE DATE: 10/03/2000|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |DAVE LOVELESS R4 |
| |M. WAYNE HODGES NMSS |
+------------------------------------------------+CHARLES MILLER IRO |
| NRC NOTIFIED BY: KENT PRENDERGAST |JOSEPH GIITTER IRO |
| HQ OPS OFFICER: LEIGH TROCINE | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|NAGR AGREEMENT STATE | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT REGARDING A SHIPMENT OF CONTAMINATED SCRAP METAL AT |
| AMERICAN METAL AND IRON COMPANY IN SAN JOSE, CALIFORNIA |
| |
| A few months ago, American Metal and Iron Company sent a shipment of scrap |
| metal to South Korea. South Korea subsequently rejected the material and |
| returned it to American Metal and Iron Company in San Jose, California, |
| because the material was contaminated with radium-226. (American Metal and |
| Iron Company is a scrap metals dealer/metal recycler, and the scrap metal |
| involved was a mixture of sheet metal conduit that had been compressed into |
| a 4' by 4' by 6' block weighing approximately 1 ton.) |
| |
| American Metal and Iron Company representatives originally thought that the |
| material had come from Lawrence Livermore and that it was the responsibility |
| of the Department of Energy (DOE). Accordingly, American Metal and Iron |
| Company representatives contacted DOE, and a DOE representative responded to |
| the site to characterize the contamination. The highest radiation reading |
| at the surface of the scrap metal was 0.2 mR/hour, and the highest wipe test |
| result was 3,000 dpm. |
| |
| DOE subsequently denied that this was their material because the contract |
| for Lawrence Livermore expired in January and because American Metal and |
| Iron Company received the material a few months ago. In addition, DOE |
| regulations would not allow DOE to sent out metal contaminated with oil. At |
| the time of this notification, American Metal and Iron Company personnel did |
| not know where they got the material. |
| |
| On the premise that this is not DOE material, the State of California |
| Radiologic Health Branch plans to assume responsibility to make sure that |
| American Metal and Iron Company either sends the material to a licensed |
| waste site for disposal or gets a health physicist to characterize the |
| material and provide a request as to why they should not sent it to a |
| licensed waste site. |
| |
| The State (Kent Prendergast) requested that this information be entered as |
| an event report and into the N-Med system. The State also reported that |
| they had received calls from both the Environmental Protection Agency (EPA) |
| and the NRC Region 4 office regarding this issue. |
| |
| HOO NOTE: At 1312 EDT on 10/03/00, the NRC Operations Center received some |
| information regarding this |
| issue from an independent marine surveyor in Oakland, CA. At 1354 EDT, the |
| same individual |
| reported that the survey meter had been read incorrectly and that this was a |
| none issue. In order to |
| ensure that all of the appropriate parties were involved and that |
| appropriate actions were being |
| taken, a conference call was subsequently conducted at 1500 EDT with |
| representatives from the |
| State of California, EPA Region IX, and the NRC. Participants included the |
| State of California Office |
| of Emergency Services (Richard Osborne) and EPA San Francisco (Terry |
| Brubaker) as well as |
| NRC representatives from the Region IV office (Dave Loveless and Dwight |
| Chamberlain), the Office |
| of Nuclear Materials Safety and Safeguards (Brian Smith and Fred Brown), and |
| Incident Response |
| Operations (Charles Miller). During this conference call, it was agreed |
| that the State would followup |
| on this event and report the results to both EPA and NRC Region IV. |
| |
| (Call the NRC operations officer for a State contact telephone number, the |
| address for American Metal and Iron Company, and the name and telephone |
| number of the independent marine surveyor.) |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37407 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: DRESDEN REGION: 3 |NOTIFICATION DATE: 10/04/2000|
| UNIT: [] [] [3] STATE: IL |NOTIFICATION TIME: 01:23[EDT]|
| RXTYPE: [1] GE-1,[2] GE-3,[3] GE-3 |EVENT DATE: 10/03/2000|
+------------------------------------------------+EVENT TIME: 21:51[CDT]|
| NRC NOTIFIED BY: SALGADO |LAST UPDATE DATE: 10/04/2000|
| HQ OPS OFFICER: JOHN MacKINNON +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |JOHN MADERA R3 |
|10 CFR SECTION: | |
|AIND 50.72(b)(2)(iii)(D) ACCIDENT MITIGATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
| | |
| | |
|3 N Y 23 Power Operation |23 Power Operation |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| HIGH PRESSURE COOLANT INJECTION (HPCI) DECLARED INOPERABLE |
| |
| Failed to receive proper indication of turbine position circuitry indicating |
| lamp following HPCI system run at rated pressure. Investigation by station |
| personnel identified a failed oil pressure switch which provides indication |
| of stop valve closure to turbine reset circuit. |
| |
| Failure of the switch prevents automatic and remote reset of HPCI turbine |
| trips. This failure renders HPCI inoperable and would prevent it from |
| fulfilling its safety function. Technical Specification 3.5.a (14 days to |
| return to service or shutdown) entered. All other Emergency Core Cooling |
| Systems are fully operable. |
| |
| Efforts are proceeding to repair/replace the switch. |
| |
| The NRC Resident Inspector will be notified of this event by the licensee. |
+------------------------------------------------------------------------------+
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021