The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.
Event Notification Report for September 6, 2000
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
09/05/2000 - 09/06/2000
** EVENT NUMBERS **
37259 37289 37290 37291 37292
!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37259 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: MCGUIRE REGION: 2 |NOTIFICATION DATE: 08/25/2000|
| UNIT: [1] [] [] STATE: NC |NOTIFICATION TIME: 18:16[EDT]|
| RXTYPE: [1] W-4-LP,[2] W-4-LP |EVENT DATE: 08/25/2000|
+------------------------------------------------+EVENT TIME: 17:30[EDT]|
| NRC NOTIFIED BY: DON BRENTON |LAST UPDATE DATE: 09/05/2000|
| HQ OPS OFFICER: FANGIE JONES +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |ROBERT HAAG R2 |
|10 CFR SECTION: |KEN BARR IAT |
|DDDD 73.71 UNSPECIFIED PARAGRAPH |JOHN DAVIDSON IAT |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| PHYSICAL SECURITY REPORT |
| |
| Potential tampering event, immediate compensatory measures taken upon |
| discovery. Contact the NRC Operations Center for additional details. |
| |
| The licensee intends to notify the NRC Resident Inspector and the R2 |
| Security Inspector (Dave Thompson). |
| |
| * * * RETRACTED AT 1206 EDT ON 9/5/00 BY VERIDA BELLAMY TO FANGIE JONES * * |
| * |
| |
| After investigation it was determined that during a planned work activity |
| workers manipulated the wrong component and it was not tampering. |
| Therefore, this event notification is retracted. There will be no written |
| followup to this event. |
| |
| The licensee notified the NRC Resident Inspector. The NRC Operations Center |
| notified the R2DO (Caudle Julian) and IAT (John Davidson). |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37289 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: MCGUIRE REGION: 2 |NOTIFICATION DATE: 09/05/2000|
| UNIT: [] [2] [] STATE: NC |NOTIFICATION TIME: 05:42[EDT]|
| RXTYPE: [1] W-4-LP,[2] W-4-LP |EVENT DATE: 09/05/2000|
+------------------------------------------------+EVENT TIME: 02:00[EDT]|
| NRC NOTIFIED BY: R.T. ELLIOT |LAST UPDATE DATE: 09/05/2000|
| HQ OPS OFFICER: JOHN MacKINNON +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |CAUDLE JULIAN R2 |
|10 CFR SECTION: | |
|AESF 50.72(b)(2)(ii) ESF ACTUATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
| | |
|2 N N 0 Cold Shutdown |0 Cold Shutdown |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| "2B" AUXILIARY FEEDWATER PUMP RAN 2 HOURS AND 55 MINUTES BEFORE BEING |
| DISCOVERED IT WAS OPERATING. STEAM GENERATORS WERE ISOLATED FROM THE AFW |
| SYSTEM. |
| |
| At 0200 ET the "B" Train of the Solid State Protection System (SSPS) was |
| deenergized for part of their refueling outage maintenance. When the SSPS |
| was deenergized the blocks for the Main Feedwater Pump blocks cleared, which |
| resulted in an automatic start signal to the "2B" AFW pump. The on shift |
| reactor operator did not notice the "2B" AFW pump run light was on until |
| 0455 ET due to refueling outage maintenance activities in Control Room. The |
| "2B" AFW pump recirculated water to the Upper Surge Tank since the Steam |
| Generators were isolated. No damage occurred to the AFW pump. The licensee |
| is investigating this event. |
| |
| The NRC Resident Inspector will be notified of this event. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Other Nuclear Material |Event Number: 37290 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: VA MEDICAL CENTER, |NOTIFICATION DATE: 09/05/2000|
|LICENSEE: VA MEDICAL CENTER |NOTIFICATION TIME: 10:20[EDT]|
| CITY: DURHAM REGION: 2 |EVENT DATE: 09/05/2000|
| COUNTY: STATE: NC |EVENT TIME: 10:10[EDT]|
|LICENSE#: 32-01134-01 AGREEMENT: Y |LAST UPDATE DATE: 09/05/2000|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |CAUDLE JULIAN R2 |
| |BRIAN SMITH NMSS |
+------------------------------------------------+ED MCALPINE R2 |
| NRC NOTIFIED BY: WALTER FURR | |
| HQ OPS OFFICER: JOHN MacKINNON | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|BAAA 20.1906(d) SURFACE CONT/ EXT RAD | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| SURFACE CONTAMINATION OF 6,300 DPM/100 CM� FOUND ON PACKAGE DELIVERED BY |
| SYNCOR OF RALEIGH, NC. |
| |
| Radiation Safety Officer (RSO) for the VA Medical Center located in Durham, |
| NC gave the following information. |
| |
| A metal ammo box containing Thallium-201 (cyclotron produced) delivered by |
| Syncor to the VA Medical Center was found to have outside surface |
| contamination levels as high as 6,300 disintegration per minute per 100 cm� |
| on the opening lid of the ammo box. The RSO called Syncor and informed them |
| of the surface contamination found on the ammo box lid. The RSO will take |
| another reading in about 6 hours using a sodium iodide probe to make sure |
| that the surface contamination is Thallium-201 instead of Technetium-99m, |
| after which the ammo box will be placed in a store room to decay. The ammo |
| box will be returned to Syncor after the outside surface contamination has |
| decayed off. |
| |
| * * * UPDATE ON 09/05/00 AT 1059 ET BY FURR TAKEN BY MACKINNON * * * |
| |
| RSO Furr has determined that the surface contamination on the outside of the |
| ammo box is Technetium-99m. R2DO (Mark Lesser) and NMSS EO (Brian Smith) |
| notified. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37291 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PALISADES REGION: 3 |NOTIFICATION DATE: 09/05/2000|
| UNIT: [1] [] [] STATE: MI |NOTIFICATION TIME: 19:19[EDT]|
| RXTYPE: [1] CE |EVENT DATE: 09/05/2000|
+------------------------------------------------+EVENT TIME: 18:25[EDT]|
| NRC NOTIFIED BY: DANIEL MALONE |LAST UPDATE DATE: 09/05/2000|
| HQ OPS OFFICER: FANGIE JONES +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |GARY SHEAR R3 |
|10 CFR SECTION: | |
|ASHU 50.72(b)(1)(i)(A) PLANT S/D REQD BY TS | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 99 Power Operation |98 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| PLANT SHUTDOWN REQUIRED PER TECHNICAL SPECIFICATIONS DUE TO POTENTIAL FOR |
| LOOSE PARTS AFFECTING EMERGENCY CORE COOLING SYSTEM OPERABILITY |
| |
| The licensee was conducting radiography examinations and discovered at 1800 |
| EDT that the internal parts of check valve CK-3332 are not in place. The |
| valve is the common miniflow recirculation line check valve for train 'A' |
| emergency core coolant system (ECCS) . A second radiography of the valve, |
| at 1825 EDT, was inclusive in determining if all the parts are located in |
| the valve body. Train 'A' ECCS was declared inoperable. Technical |
| specification 3.0.3 was entered at 1901 EDT due to the possibility that |
| loose parts may adversely affect the operability of other ECCS components |
| and the plant has commenced shutdown. |
| |
| The licensee has notified the NRC Resident Inspector. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37292 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: DUANE ARNOLD REGION: 3 |NOTIFICATION DATE: 09/05/2000|
| UNIT: [1] [] [] STATE: IA |NOTIFICATION TIME: 20:15[EDT]|
| RXTYPE: [1] GE-4 |EVENT DATE: 09/05/2000|
+------------------------------------------------+EVENT TIME: 18:10[CDT]|
| NRC NOTIFIED BY: TIM ALLEN |LAST UPDATE DATE: 09/05/2000|
| HQ OPS OFFICER: FANGIE JONES +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |GARY SHEAR R3 |
|10 CFR SECTION: | |
|AINB 50.72(b)(2)(iii)(B) POT RHR INOP | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| BOTH TRAINS OF RIVER WATER SUPPLY SYSTEM DECLARED INOPERABLE |
| |
| The licensee had a failure of the river water instrument air system at 1810 |
| CDT, resulting in the loss of the automatic traveling screen control and the |
| high screen differential level alarm function. With both automatic screen |
| wash functions inoperable, both river water supply systems were declared |
| inoperable. The systems were returned to operable at 1820 CDT when the |
| alternate air dryer was placed in service, the problem being the air dryer |
| that had been in service stopped passing air. |
| |
| The licensee notified the NRC Resident Inspector. |
+------------------------------------------------------------------------------+
Page Last Reviewed/Updated Wednesday, March 24, 2021
Page Last Reviewed/Updated Wednesday, March 24, 2021