Skip to main content

Event Notification Report for August 21, 2000

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           08/18/2000 - 08/21/2000

                              ** EVENT NUMBERS **

37164  37232  37237  37238  37239  37240  

+------------------------------------------------------------------------------+
|Other Nuclear Material                           |Event Number:   37164       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  LAW ENG. AND ENV. SERVICES           |NOTIFICATION DATE: 07/12/2000|
|LICENSEE:  LAW ENG. AND ENV. SERVICES           |NOTIFICATION TIME: 12:39[EDT]|
|    CITY:  ALPHERETTA               REGION:  2  |EVENT DATE:        07/11/2000|
|  COUNTY:                            STATE:  GA |EVENT TIME:             [EDT]|
|LICENSE#:  45-21498-01           AGREEMENT:  Y  |LAST UPDATE DATE:  08/19/2000|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |THOMAS DECKER        R2      |
|                                                |DONALD COOL          NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  DAVID RUMWILL                |                             |
|  HQ OPS OFFICER:  BOB STRANSKY                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|BAB1 20.2201(a)(1)(i)    LOST/STOLEN LNM>1000X  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| MISSING MOISTURE/DENSITY GAUGE                                               |
|                                                                              |
| The licensee reported that a Troxler Model 3411 nuclear moisture/density     |
| gauge containing 8 mCi of Cs-137 and 40 mCi of Am-241/Be (S/N 18561) was     |
| missing from the Sterling, VA area. A company employee, who resides in West  |
| Virginia, was scheduled to bring the gauge to a job site in the northern VA  |
| area on 7/11/2000, but failed to show up. Neither the individual, the        |
| company vehicle that he was using, nor the gauge can be located. The company |
| last had contact with the employee on 7/7/2000. The licensee did not believe |
| that the individual was a disgruntled employee. The licensee has contacted   |
| local law enforcement agencies regarding the missing individual and gauge.   |
|                                                                              |
| ***** UPDATE AT 1820 ON 08/19/00 BY LEIGH TROCINE *****                      |
|                                                                              |
| The following text is a portion of Preliminary Notification of Event or      |
| Unusual Occurrence PNO-II-00-027A dated 08/18/00:                            |
|                                                                              |
| "On July 12, 2000, the licensee informed the [NRC] Region II office of a     |
| missing Troxler Electronic Laboratories Model 3411 portable gauge.  The      |
| licensee recovered the portable gauge, vehicle[,] and other stolen equipment |
| on August 15, 2000.  The radioactive sources in the gauge have been tested   |
| for potential leakage and contamination of radioactive material.  There was  |
| no evidence of leakage or contamination."                                    |
|                                                                              |
| "This information is current as of 1045 on August 18, 2000."                 |
|                                                                              |
| "The Commonwealth of Virginia and State of West Virginia have been notified  |
| [by Region II personnel.]                                                    |
|                                                                              |
| The NRC operations officer notified the R2DO (Fredrickson) and NMSS EO       |
| (Ting).                                                                      |
+------------------------------------------------------------------------------+

!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED  !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37232       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: FARLEY                   REGION:  2  |NOTIFICATION DATE: 08/16/2000|
|    UNIT:  [] [2] []                 STATE:  AL |NOTIFICATION TIME: 17:59[EDT]|
|   RXTYPE: [1] W-3-LP,[2] W-3-LP                |EVENT DATE:        08/16/2000|
+------------------------------------------------+EVENT TIME:        16:25[CDT]|
| NRC NOTIFIED BY:  G RHODES                     |LAST UPDATE DATE:  08/18/2000|
|  HQ OPS OFFICER:  JOHN MacKINNON               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          ALE                   |PAUL FREDRICKSON     R2      |
|10 CFR SECTION:                                 |WILLIAM BECKNER      NRR     |
|                                                |FRANK CONGEL         IRO     |
|                                                |BARDEN               FEMA    |
|                                                |YATES                DOE     |
|                                                |LORI THOMAS          USDA    |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| SMOKE SEEN COMING FROM "2C" SERVICE WATER PUMP MOTOR                         |
|                                                                              |
| "2C" Service Water Pump (swing) motor was seen having smoke coming from it.  |
| On site fire brigade was sent out to the Service Water building and          |
| extinguished the fire at 1609 CT.  The licensee declared an Alert at 1625 CT |
| due to the potential of the fire affecting ECCS equipment.  No offsite       |
| assistance was needed and no other equipment onsite was damaged by the fire. |
| Service Water Pumps "2A", "2B", "2D", & "2E" remain in service.  All         |
| Emergency Core Cooling Systems are fully operable if needed.                 |
|                                                                              |
| Fire Alarm for Service Water pump was received in control room at 1548 CT.   |
| A  person was immediately dispatched to investigate the alarm. Person        |
| reported back to control room at 1552 CT that smoke was coming from "2C"     |
| Service Water motor.  Licensee entered AOP 29 (Plant Fire) at 1552 CT.  At   |
| 1555 CT "2C" Service Water Pump tripped for unknown reason.  Service Water   |
| pump flow was degraded for approximately 15 seconds at which time another    |
| Service Water pump was placed in service.  Lowest service water pressure     |
| reached was 70 psi (min pressure is 60 psi).  At 1609 CT  report received    |
| that fire had been extinguished using carbon dioxide.  1616 CT AOP 29 was    |
| exited.   The licensee notified state and local officials of entering Alert  |
| classification.                                                              |
|                                                                              |
| The NRC Resident Inspector was in the control room during the event.         |
|                                                                              |
| NRC Operation Center was notified by Brad Grinstead of the Alabama           |
| Department of Public Health and by Kerri Seber of the Florida State Warning  |
| Point of the Farley Unit 2 Alert.                                            |
|                                                                              |
| * * * UPDATE ON 08/16/00 AT 1845 ET BY G RHODES TAKEN BY MACKINNON * * *     |
|                                                                              |
| Alert was terminated at 1736 CT due to fire being out and all systems        |
| operating properly.                                                          |
|                                                                              |
| NRC R2DO (Paul Fredrickson), Acting DEDR (Ellis Merschoff), IRO (Frank       |
| Congel), NRR EO (Bill Beckner),  NRC PAO (Bill Beecher), NRR (Roy            |
| Zimmerman), EDO STAFF (Mark Satorius), NRC RCT (John Jolicoeur), FEMA        |
| (Belcher), DOE (Yates), USDA (Lori Thomas), EPA Reg IV (Runge), and HHS      |
| (Burger), notified.                                                          |
|                                                                              |
| The NRC Resident Inspector was onsite in control room during this event.     |
|                                                                              |
| * * * UPDATE ON 08/16/00 AT 2031 ET BY G. RHODES TAKEN BY MACKINNON * * *    |
|                                                                              |
| "At 1625 [CT] FNP staff declared an Alert Emergency classification based on  |
| criteria found in site procedures.  The 2C Service Water Pump motor had      |
| faulted resulting in a small fire in the Service Water Intake Structure.     |
| The Site Fire Brigade responded and the fire was extinguished promptly.  No  |
| other equipment was damaged.  The FNP Unit 2 Service Water system has 5      |
| pumps and requires 2 pumps per train (4 pumps total) to ensure that system   |
| design functions are met.  The 2C Service Water Pump is a swing pump that    |
| can be aligned to either train.  The remaining four Unit 2 Service Water     |
| pumps are currently operable and in service.                                 |
|                                                                              |
| "The FNP staff has assessed this event.  No plant personnel were injured and |
| only limited damage to plant equipment as described above occurred.  There   |
| was no affect on the health and safety of the general public and no release  |
| of radiation.  The Alert was terminated at 1736 [CT].  Both Units are        |
| continuing to operate at 100% power."                                        |
|                                                                              |
| R2DO (Paul Fredrickson) & IRO (Congel) notified.                             |
|                                                                              |
| The NRC Resident Inspector was notified of this update by the licensee.      |
|                                                                              |
| ***** UPDATE/RETRACTION AT 1727 ON 08/18/00 FROM CHERI COLLINS TO LEIGH      |
| TROCINE *****                                                                |
|                                                                              |
| The licensee is retracting this event notification.  The following text is a |
| portion of a facsimile received from the licensee:                           |
|                                                                              |
| "Farley Nuclear Plant ENS Update - Retraction of Alert Emergency due to Fire |
| at the Service Water Intake Structure"                                       |
|                                                                              |
| "Farley Nuclear Plant [(FNP)] is retracting the Alert Emergency Declaration  |
| that occurred at 1625 CDT and was terminated at 1736 CDT on August 16, 2000. |
| FNP Staff personnel made this declaration based on a conservative            |
| interpretation of the classification requirements in their internal site     |
| procedures.  The site procedure requires an Alert Classification to be       |
| declared when a fire occurs that potentially affects Emergency Core Cooling  |
| Systems (ECCS).  The Service Water System supplies cooling water to ECCS     |
| components, and therefore, when a 2C Service Water Pump motor fault occurred |
| requiring site fire brigade response, FNP staff felt that the most           |
| appropriate and conservative approach was to declare the Alert               |
| Classification."                                                             |
|                                                                              |
| "Subsequently, [the] FNP Staff determined that while there was a fire        |
| internal to the motor casing of the 2C Service Water Pump, the ECCS was not  |
| affected since the required number of Service Water pumps remained available |
| to support ECCS operation.  Although a fire in a vital area represents a     |
| potential safety hazard, this fire did not rise to the level of safety       |
| hazard warranting an Alert Emergency Classification.  [The] FNP Staff now    |
| believes that no classification should have been declared, and we are        |
| retracting this event notification."                                         |
|                                                                              |
| The licensee notified the Alabama Department of the Emergency Management,    |
| Georgia Emergency Management Agency, Florida Division of Emergency           |
| Management , and other appropriate local officials.  The licensee has also   |
| notified the NRC resident inspector.  In addition, the licensee plans to     |
| issue a press release on Monday (08/21/00).                                  |
|                                                                              |
| The NRC operations officer notified the R2DO (Fredrickson), NRR EO           |
| (Beckner), IRO (Miller), and PAO (Beecher).                                  |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Transportation                                   |Event Number:   37237       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  AGILENT TECHNOLOGIES                 |NOTIFICATION DATE: 08/18/2000|
|LICENSEE:  AGILENT TECHNOLOGIES                 |NOTIFICATION TIME: 08:30[EDT]|
|    CITY:  WILMINGTON               REGION:  1  |EVENT DATE:        07/19/2000|
|  COUNTY:                            STATE:  DE |EVENT TIME:             [EDT]|
|LICENSE#:  07-28762-02G          AGREEMENT:  N  |LAST UPDATE DATE:  08/18/2000|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |CLIFFORD ANDERSON    R1      |
|                                                |CHUCK PAULK          R4      |
+------------------------------------------------+JOHN HICKEY          NMSS    |
| NRC NOTIFIED BY:  DAVID BENNETT                |DOE, DOT via fax             |
|  HQ OPS OFFICER:  STEVE SANDIN                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|BAB2 20.2201(a)(1)(ii)   LOST/STOLEN LNM>10X    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| MISSING Ni-63 SOURCE                                                         |
|                                                                              |
| In early May 2000, Agilent Technologies shipped two(2) 15 mCi Ni-63 sources  |
| to Sandia Lab located in Albuquerque, NM.  The Lab had only ordered one(1)   |
| source.  When the second source arrived the Sandia shipping department       |
| notified their accounting staff who directed that they return the item to    |
| Agilent.  Agilent was not informed of the error nor was a return             |
| authorization or FEDEX tracking number obtained.  Agilent has no record of   |
| receiving the returned source.  The missing source is an electron capture    |
| detector Model #G2397A, S/N U2216 [general license].  The RSO was informed   |
| of the incident on 7/19 and determined that the error occurred due to a      |
| problem with the FEDEX labeling system.   Agilent shipping department        |
| prepared a separate label for the first shipment since their FEDEX labeling  |
| system  was not available that morning.  When the labeler was restored, a    |
| label was prepared which resulted in a second shipment to Sandia.  FEDEX was |
| informed of the missing shipment by Sandia personnel.                        |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Other Nuclear Material                           |Event Number:   37238       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  KEEGAN TECHNOLOGY AND TESTING        |NOTIFICATION DATE: 08/18/2000|
|LICENSEE:  KEEGAN TECHNOLOGY AND TESTING        |NOTIFICATION TIME: 13:53[EDT]|
|    CITY:  KEYPORT                  REGION:  1  |EVENT DATE:        08/18/2000|
|  COUNTY:  MONMOUTH                  STATE:  NJ |EVENT TIME:        13:00[EDT]|
|LICENSE#:  29-19282-01           AGREEMENT:  N  |LAST UPDATE DATE:  08/18/2000|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |CLIFFORD ANDERSON    R1      |
|                                                |BRIAN SMITH          NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  BILL BOEHLER                 |                             |
|  HQ OPS OFFICER:  LEIGH TROCINE                |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|BAB2 20.2201(a)(1)(ii)   LOST/STOLEN LNM>10X    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| HUMBOLT NUCLEAR DENSITY GAUGE STOLEN FROM A JOBSITE LOCATED IN HILLSIDE, NEW |
| JERSEY.                                                                      |
|                                                                              |
| At approximately 1300 on 08/18/00, a Humbolt soil moisture density gauge     |
| (model #5001C, serial number 1852) was stolen from a jobsite located in      |
| Hillside, New Jersey.  Apparently, the gauge was locked inside its case, and |
| the case was located inside an unlocked truck.  It was reported that the     |
| gauge user entered and exited a trailer and discovered the gauge to be       |
| missing after exiting the trailer.                                           |
|                                                                              |
| The gauge contained cesium-137 and americium-241/beryllium sources.  The     |
| activity levels of the sources were not known at the time of this            |
| notification.                                                                |
|                                                                              |
| The licensee notified both the Hillside New Jersey Police Department and the |
| NRC Region 3 office (John McGrath).                                          |
|                                                                              |
| (Contact the NRC operations officer for the licensee's contact telephone     |
| number and address as well as the contact name, telephone number, and case   |
| number for the Hillside New Jersey Police Department.)                       |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37239       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: HARRIS                   REGION:  2  |NOTIFICATION DATE: 08/19/2000|
|    UNIT:  [1] [] []                 STATE:  NC |NOTIFICATION TIME: 00:09[EDT]|
|   RXTYPE: [1] W-3-LP                           |EVENT DATE:        08/18/2000|
+------------------------------------------------+EVENT TIME:        19:35[EDT]|
| NRC NOTIFIED BY:  DAVIS                        |LAST UPDATE DATE:  08/19/2000|
|  HQ OPS OFFICER:  CHAUNCEY GOULD               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |PAUL FREDRICKSON     R2      |
|10 CFR SECTION:                                 |                             |
|AESS 50.72(b)(1)(v)      EMERGENCY SIREN INOP   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| PLANT HAD GREATER THAN 20% OF THEIR WARNING SIRENS OUT OF SERVICE.           |
|                                                                              |
| More than 17 of the 81 warning sirens became out of service due to power     |
| outages.  This represents greater than 20% of the warning sirens, therefore  |
| making it reportable.  The number of warning sirens available was back       |
| within acceptable limits at 2035 on 8/18/00.  Currently only 8 warning       |
| sirens are out of service.  This information was obtained at 2320 and        |
| determined reportable at 2327.                                               |
|                                                                              |
| The NRC Resident Inspector, the State and local agencies will be informed.   |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37240       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: INDIAN POINT             REGION:  1  |NOTIFICATION DATE: 08/19/2000|
|    UNIT:  [2] [] []                 STATE:  NY |NOTIFICATION TIME: 16:10[EDT]|
|   RXTYPE: [2] W-4-LP,[3] W-4-LP                |EVENT DATE:        08/19/2000|
+------------------------------------------------+EVENT TIME:        11:05[EDT]|
| NRC NOTIFIED BY:  DENNIS CORNAX                |LAST UPDATE DATE:  08/19/2000|
|  HQ OPS OFFICER:  LEIGH TROCINE                +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |CLIFFORD ANDERSON    R1      |
|10 CFR SECTION:                                 |PHILIP TING          NMSS    |
|NONR                     OTHER UNSPEC REQMNT    |WILLIAM BECKNER      NRR     |
|                                                |CHARLES MILLER       IRO     |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|2     N          N       0        Refueling        |0        Refueling        |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| FAILURE OF A 35-CURIE IRIDIUM-192 SOURCE TO RETRACT TO ITS SHIELDED POSITION |
| WITHIN A RADIOGRAPHY CAMERA OPERATED BY RAYTHEON PERSONNEL (48-HOUR REPORT   |
| BASED ON MANAGEMENT DISCRETION)                                              |
|                                                                              |
| The following text is a portion of a facsimile received from the licensee:   |
|                                                                              |
| "CONDITION DESCRIPTION:"                                                     |
|                                                                              |
| "[A] radiography source would not return to shielded container of camera.    |
| On 19 August 2000, Washington Group (Raytheon) was conducting radiography on |
| welder test coupons in the CSB Hallway, 53' elevation.  The radiography was  |
| being conducted under [Radiation Work Permit (RWP)] 491 utilizing a 35-curie |
| [Iridium]-192 source, license number L02662.  The task had continuous        |
| [Health Physics (HP)] coverage assigned.  The following is a synopsis of the |
| event:"                                                                      |
|                                                                              |
| "1.  All notifications and announcements for radiography were completed."    |
| "2.  The first shot was a scheduled 45-second shot and commenced at 1105."   |
| "3.  Following the exposure period, the source was retracted.  The           |
| radiographer noted that he had not heard the                                 |
| characteristic 'snap' signifying full retraction."                           |
| "4.  By operating guidance, the radiographer ran out the source and          |
| attempted retraction.  This effort was                                       |
| unsuccessful."                                                               |
| "5.  [The] radiographer noted that the emergency procedure was with the      |
| camera, thus unavailable.  [The]                                             |
| radiographer obtained an additional copy of the procedure from [the] onsite  |
| office."                                                                     |
| "6.  The source was run out again to full exposure and again retracted.      |
| Indication on the camera was that both                                       |
| the red and green [lights] were lit, indicating the source was in an         |
| intermediate reaction."                                                      |
| "7.  At approximately 1127, the radiographer informed the HP Technician that |
| they were entering their emergency                                           |
| procedure.  The HP technician notified the ConEd HP supervisor of the        |
| event."                                                                      |
| "8.  The ConEd HP supervisor reported to the scene at 1135 and notified SGR  |
| HP staff of the event."                                                      |
| "9.  At 1140, the source was fully retracted following two more attempts."   |
| "10.  The camera was surveyed to confirm full retraction."                   |
| "11.  The camera was secured in the 53' NSB source vault, and RWP 491 was    |
| placed on hold pending                                                       |
| investigation of the event."                                                 |
|                                                                              |
| "Subsequent to the event, the radiographer met with SGR HP management and    |
| [committed] that this camera [would] not be utilized and [would be] tagged   |
| as such.  The radiographer stated that the camera [would] have to be         |
| transported to their home office for maintenance/repair.  Written statements |
| were obtained from the principal parties[,] and relative documentation for   |
| the event [has] been gathered [...] ."                                       |
|                                                                              |
| "IMMEDIATE ACTION:"                                                          |
|                                                                              |
| "The following actions were taken:"                                          |
|                                                                              |
| "1.  ConEd Hp management [was] notified of the event."                       |
| "2.  Personnel that were involved in the event were assembled, and the       |
| sequence of events [was] ascertained."                                       |
| "3.  The camera was locked in the 53' NSB source vault."                     |
| "4.  RWP 491 was placed in an on hold status."                               |
| "5.  The radiographer assured SGR HP management that the camera would not be |
| returned to service and                                                      |
| would be tagged as such."                                                    |
| "6.  SGR and SGT project management were notified."                          |
|                                                                              |
| The licensee stated the no one was exposed and that everything was properly  |
| shielded and monitored by HP personnel.  The work was being performed in a   |
| hallway located in a support facility.  The hallway was not used for         |
| traffic, and it was shielded with heavy concrete.  The brand name of the     |
| radiography camera was not available at the time of this report.             |
|                                                                              |
| The licensee decided to notify the state of this event, and the control room |
| was informed of this decision at 1358.  The decision to notify the NRC was   |
| made as a 48-hour report per procedure based on management discretion.  At   |
| the time of the licensee's notification to the NRC, the licensee had         |
| notified the state and planned to notify the NRC resident inspector.         |
+------------------------------------------------------------------------------+