|Power Reactor |Event Number: 37210 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: OYSTER CREEK REGION: 1 |NOTIFICATION DATE: 08/07/2000|
| UNIT: [1] [] [] STATE: NJ |NOTIFICATION TIME: 11:13[EDT]|
| RXTYPE: [1] GE-2 |EVENT DATE: 08/07/2000|
+------------------------------------------------+EVENT TIME: 10:50[EDT]|
| NRC NOTIFIED BY: ERIC DeMONCH |LAST UPDATE DATE: 08/07/2000|
| HQ OPS OFFICER: FANGIE JONES +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |LAWRENCE DOERFLEIN R1 |
|10 CFR SECTION: | |
|APRE 50.72(b)(2)(vi) OFFSITE NOTIFICATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 92 Power Operation |92 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| SMALL ONSITE OIL LEAK REQUIRED OFFSITE NOTIFICATION |
| |
| There was a spill of about 10 gallons of hydraulic oil from a contracted |
| bucket truck on the backside of the site, work was being performed on |
| overhead lines. The spill was contained and cleanup is in progress. |
| |
| The licensee notified the NRC Resident Inspector, the New Jersey Department |
| of Environmental Protection and the Ocean County Department of Health. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37211 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SAINT LUCIE REGION: 2 |NOTIFICATION DATE: 08/07/2000|
| UNIT: [1] [2] [] STATE: FL |NOTIFICATION TIME: 12:00[EDT]|
| RXTYPE: [1] CE,[2] CE |EVENT DATE: 08/07/2000|
+------------------------------------------------+EVENT TIME: 08:13[EDT]|
| NRC NOTIFIED BY: ALAN HALL |LAST UPDATE DATE: 08/07/2000|
| HQ OPS OFFICER: FANGIE JONES +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |GEORGE BELISLE R2 |
|10 CFR SECTION: | |
|APRE 50.72(b)(2)(vi) OFFSITE NOTIFICATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
|2 N Y 100 Power Operation |100 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION DUE TO A DEAD IMMATURE SPERM WHALE FOUND NEAR SITE |
| |
| The licensee made a courtesy call to the Florida Fish and Wildlife |
| Conservation Commission and the Florida Marine Patrol were notified of a |
| dead immature sperm whale was discovered in the surf in the front of the |
| licensee's property (not on the property). |
| |
| The licensee notified the NRC Resident Inspector. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37212 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PEACH BOTTOM REGION: 1 |NOTIFICATION DATE: 08/08/2000|
| UNIT: [] [3] [] STATE: PA |NOTIFICATION TIME: 01:24[EDT]|
| RXTYPE: [2] GE-4,[3] GE-4 |EVENT DATE: 08/07/2000|
+------------------------------------------------+EVENT TIME: 21:26[EDT]|
| NRC NOTIFIED BY: WINGFIELD |LAST UPDATE DATE: 08/08/2000|
| HQ OPS OFFICER: CHAUNCEY GOULD +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |LAWRENCE DOERFLEIN R1 |
|10 CFR SECTION: | |
|ARPS 50.72(b)(2)(ii) RPS ACTUATION | |
|AESF 50.72(b)(2)(ii) ESF ACTUATION | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
| | |
|3 A/R Y 100 Power Operation |0 Hot Shutdown |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| REACTOR SCRAM FROM 100% POWER ON A FALSE LOW REACTOR WATER LEVEL INDICATION |
| |
| The Unit experienced an automatic reactor scram when an instrument line |
| "root" valve failed causing a water leak which resulted in a false low |
| reactor water level signal indication to be sensed by the RPS. The water |
| leak was immediately isolated by the ESF actuation of the Excess Flow Check |
| Valve in the same reactor instrumentation line. All rods fully inserted, no |
| ECCS injection occurred, no relief valves lifted and all safety systems |
| responded correctly. The plant also had actuation of the Primary |
| Containment Isolation System following the reactor scram. |
| |
| The NRC Resident Inspector will be notified. |
+------------------------------------------------------------------------------+