The U.S. Nuclear Regulatory Commission is in the process of rescinding or revising guidance and policies posted on this webpage in accordance with Executive Order 14151 Ending Radical and Wasteful Government DEI Programs and Preferencing, and Executive Order 14168 Defending Women From Gender Ideology Extremism and Restoring Biological Truth to the Federal Government. In the interim, any previously issued diversity, equity, inclusion, or gender-related guidance on this webpage should be considered rescinded that is inconsistent with these Executive Orders.

Event Notification Report for August 4, 2000

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           08/03/2000 - 08/04/2000

                              ** EVENT NUMBERS **

37148  37206  37207  

!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED  !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37148       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: DRESDEN                  REGION:  3  |NOTIFICATION DATE: 07/07/2000|
|    UNIT:  [] [2] [3]                STATE:  IL |NOTIFICATION TIME: 05:18[EDT]|
|   RXTYPE: [1] GE-1,[2] GE-3,[3] GE-3           |EVENT DATE:        07/07/2000|
+------------------------------------------------+EVENT TIME:        02:05[CDT]|
| NRC NOTIFIED BY:  DAVID THRONE                 |LAST UPDATE DATE:  08/03/2000|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |MICHAEL JORDAN       R3      |
|10 CFR SECTION:                                 |                             |
|AIND 50.72(b)(2)(iii)(D) ACCIDENT MITIGATION    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|3     N          Y       100      Power Operation  |100      Power Operation  |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| MAIN CONTROL ROOM HVAC EMERGENCY VENTILATION DECLARED INOPERABLE             |
|                                                                              |
| "During performance of scheduled monthly surveillance testing, it was        |
| determined that overall differential pressure on the Main Control Room HVAC  |
| Emergency Ventilation Train Air Filtration Unit (AFU) was out of             |
| specification high. The AFU is a single train system required to provide     |
| habitable conditions for control room personnel during design basis accident |
| conditions. This condition is reportable under the requirements of SAF 1.17  |
| 'Could alone have prevented safety function.'  and 10CFR50.72(b). This       |
| condition places both Units in a 7 day shutdown LCO."                        |
|                                                                              |
| The licensee will inform the NRC Resident Inspector.                         |
|                                                                              |
| * * * RETRACTION AT 1755 ET ON 08/03/00 BY KEN HOUSH TAKEN BY MACKINNON * *  |
| *                                                                            |
|                                                                              |
| A more detailed review performed by Dresden Operations and Engineering       |
| personnel has determined that the Differential Pressure across the Air       |
| Filtration Unit filter could be up to a maximum of 10 inches of water gauge  |
| and perform its design function.  The Technical Specification value will be  |
| increased to the maximum allowable value (at least 8.0 inches of water       |
| gauge);  which will remain within the design parameters required for each    |
| component of the Control Room HVAC system.  The Control Room HVAC system was |
| able to perform its intended safety function and therefore the reportability |
| of CFR 50.72(b)(2)(iii)D does not apply to this condition.  NRC R3DO (Jim    |
| Creed) notified.                                                             |
|                                                                              |
| On 07/07/00 at 0205 CT the Control Room HVAC Air Filtration Unit             |
| Differential Pressure was found to be at 6.03 inches of water which is above |
| their Technical Specification 3/4.8.D  during a routine surveillance test.   |
|                                                                              |
| The NRC Resident Inspector will be notified of this event retraction by the  |
| licensee.                                                                    |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Other Nuclear Material                           |Event Number:   37206       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  CONAM INSPECTION                     |NOTIFICATION DATE: 08/03/2000|
|LICENSEE:  CONAM INSPECTION                     |NOTIFICATION TIME: 11:03[EDT]|
|    CITY:  TRAINER                  REGION:  1  |EVENT DATE:        08/02/2000|
|  COUNTY:                            STATE:  PA |EVENT TIME:        11:15[EDT]|
|LICENSE#:  12-16559-02           AGREEMENT:  N  |LAST UPDATE DATE:  08/03/2000|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |JACK MCFADDEN        R1      |
|                                                |FREDRICK STURZ       NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  BOB SLACK                    |                             |
|  HQ OPS OFFICER:  FANGIE JONES                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|IBBF 30.50(b)(2)(ii)     EQUIP DISABLED/FAILS   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| INDUSTRIAL RADIOGRAPHY SOURCE STUCK IN THE OUT POSITION                      |
|                                                                              |
| Conam Inspection was performing radiographs at the Tosco Refinery in         |
| Trainer, PA.  During the performance of a shot, the source assembly fell     |
| over denting the source tube preventing the recovery of the source (64       |
| curies of Iridium-192).  The area had already been secured for the           |
| radiography operation and lead shot was used to cover the source until       |
| recovery of the source could be made.  The regional Radiation Safety Officer |
| (RSO) was contacted and reported to the site.  Repairs were made to the      |
| source tube and the source was recovered.                                    |
|                                                                              |
| A thirty day written report will be made.                                    |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37207       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SURRY                    REGION:  2  |NOTIFICATION DATE: 08/03/2000|
|    UNIT:  [1] [2] []                STATE:  VA |NOTIFICATION TIME: 12:16[EDT]|
|   RXTYPE: [1] W-3-LP,[2] W-3-LP                |EVENT DATE:        08/03/2000|
+------------------------------------------------+EVENT TIME:        11:21[EDT]|
| NRC NOTIFIED BY:  M SMITH                      |LAST UPDATE DATE:  08/03/2000|
|  HQ OPS OFFICER:  JOHN MacKINNON               +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |GEORGE BELISLE       R2      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(vi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| POTENTIAL OIL SPILL TO JAMES RIVER                                           |
|                                                                              |
| REPORT IS BEING MADE UNDER CORE OF VIRGINIA 62.1-44.34:19, REPORTING OF      |
| DISCHARGE.                                                                   |
|                                                                              |
| WHILE PERFORMING WORK ON FISH FLUME PIPING AT THE LOW LEVEL INTAKE           |
| STRUCTURE, A BACKHOE LOST TRACTION AND SLID INTO DEEPER WATER.  THE BACKHOE  |
| WAS IN STATE WATERS (JAMES RIVER) FOR THIS EVENT.  FUEL OIL WAS REMOVED AND  |
| POTENTIAL OIL PATHS WERE PLUGGED TO PREVENT OIL DISCHARGE TO THE JAMES       |
| RIVER.  ALSO AN OIL BOOM WAS PLACED AROUND THE BACKHOE.  NO OIL WAS OBSERVED |
| ON THE SURFACE OF THE WATER.  THE STATE DEQ AND NATIONAL RESPONSE CENTER     |
| HAVE BEEN NOTIFIED OF THE THREAT THAT OIL WILL ENTER STATE WATERS.  THIS     |
| REPORT IS BEING MADE UNDER CODE OF VIRGINIA 62.1-44.34:19, REPORTING OF      |
| DISCHARGE.                                                                   |
|                                                                              |
| THE NRC RESIDENT INSPECTOR WILL BE INFORMED OF THIS EVENT BY TH E LICENSEE.  |
+------------------------------------------------------------------------------+


Page Last Reviewed/Updated Thursday, March 25, 2021