Event Notification Report for August 4, 2000
U.S. Nuclear Regulatory Commission Operations Center Event Reports For 08/03/2000 - 08/04/2000 ** EVENT NUMBERS ** 37148 37206 37207 !!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED !!!!!!! +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 37148 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: DRESDEN REGION: 3 |NOTIFICATION DATE: 07/07/2000| | UNIT: [] [2] [3] STATE: IL |NOTIFICATION TIME: 05:18[EDT]| | RXTYPE: [1] GE-1,[2] GE-3,[3] GE-3 |EVENT DATE: 07/07/2000| +------------------------------------------------+EVENT TIME: 02:05[CDT]| | NRC NOTIFIED BY: DAVID THRONE |LAST UPDATE DATE: 08/03/2000| | HQ OPS OFFICER: STEVE SANDIN +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |MICHAEL JORDAN R3 | |10 CFR SECTION: | | |AIND 50.72(b)(2)(iii)(D) ACCIDENT MITIGATION | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ | | | |2 N Y 100 Power Operation |100 Power Operation | |3 N Y 100 Power Operation |100 Power Operation | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | MAIN CONTROL ROOM HVAC EMERGENCY VENTILATION DECLARED INOPERABLE | | | | "During performance of scheduled monthly surveillance testing, it was | | determined that overall differential pressure on the Main Control Room HVAC | | Emergency Ventilation Train Air Filtration Unit (AFU) was out of | | specification high. The AFU is a single train system required to provide | | habitable conditions for control room personnel during design basis accident | | conditions. This condition is reportable under the requirements of SAF 1.17 | | 'Could alone have prevented safety function.' and 10CFR50.72(b). This | | condition places both Units in a 7 day shutdown LCO." | | | | The licensee will inform the NRC Resident Inspector. | | | | * * * RETRACTION AT 1755 ET ON 08/03/00 BY KEN HOUSH TAKEN BY MACKINNON * * | | * | | | | A more detailed review performed by Dresden Operations and Engineering | | personnel has determined that the Differential Pressure across the Air | | Filtration Unit filter could be up to a maximum of 10 inches of water gauge | | and perform its design function. The Technical Specification value will be | | increased to the maximum allowable value (at least 8.0 inches of water | | gauge); which will remain within the design parameters required for each | | component of the Control Room HVAC system. The Control Room HVAC system was | | able to perform its intended safety function and therefore the reportability | | of CFR 50.72(b)(2)(iii)D does not apply to this condition. NRC R3DO (Jim | | Creed) notified. | | | | On 07/07/00 at 0205 CT the Control Room HVAC Air Filtration Unit | | Differential Pressure was found to be at 6.03 inches of water which is above | | their Technical Specification 3/4.8.D during a routine surveillance test. | | | | The NRC Resident Inspector will be notified of this event retraction by the | | licensee. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Other Nuclear Material |Event Number: 37206 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | REP ORG: CONAM INSPECTION |NOTIFICATION DATE: 08/03/2000| |LICENSEE: CONAM INSPECTION |NOTIFICATION TIME: 11:03[EDT]| | CITY: TRAINER REGION: 1 |EVENT DATE: 08/02/2000| | COUNTY: STATE: PA |EVENT TIME: 11:15[EDT]| |LICENSE#: 12-16559-02 AGREEMENT: N |LAST UPDATE DATE: 08/03/2000| | DOCKET: |+----------------------------+ | |PERSON ORGANIZATION | | |JACK MCFADDEN R1 | | |FREDRICK STURZ NMSS | +------------------------------------------------+ | | NRC NOTIFIED BY: BOB SLACK | | | HQ OPS OFFICER: FANGIE JONES | | +------------------------------------------------+ | |EMERGENCY CLASS: N/A | | |10 CFR SECTION: | | |IBBF 30.50(b)(2)(ii) EQUIP DISABLED/FAILS | | | | | | | | | | | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | INDUSTRIAL RADIOGRAPHY SOURCE STUCK IN THE OUT POSITION | | | | Conam Inspection was performing radiographs at the Tosco Refinery in | | Trainer, PA. During the performance of a shot, the source assembly fell | | over denting the source tube preventing the recovery of the source (64 | | curies of Iridium-192). The area had already been secured for the | | radiography operation and lead shot was used to cover the source until | | recovery of the source could be made. The regional Radiation Safety Officer | | (RSO) was contacted and reported to the site. Repairs were made to the | | source tube and the source was recovered. | | | | A thirty day written report will be made. | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ |Power Reactor |Event Number: 37207 | +------------------------------------------------------------------------------+ +------------------------------------------------------------------------------+ | FACILITY: SURRY REGION: 2 |NOTIFICATION DATE: 08/03/2000| | UNIT: [1] [2] [] STATE: VA |NOTIFICATION TIME: 12:16[EDT]| | RXTYPE: [1] W-3-LP,[2] W-3-LP |EVENT DATE: 08/03/2000| +------------------------------------------------+EVENT TIME: 11:21[EDT]| | NRC NOTIFIED BY: M SMITH |LAST UPDATE DATE: 08/03/2000| | HQ OPS OFFICER: JOHN MacKINNON +-----------------------------+ +------------------------------------------------+PERSON ORGANIZATION | |EMERGENCY CLASS: N/A |GEORGE BELISLE R2 | |10 CFR SECTION: | | |APRE 50.72(b)(2)(vi) OFFSITE NOTIFICATION | | | | | | | | | | | +-----+----------+-------+--------+-----------------+--------+-----------------+ |UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE | +-----+----------+-------+--------+-----------------+--------+-----------------+ |1 N Y 100 Power Operation |100 Power Operation | |2 N Y 100 Power Operation |100 Power Operation | | | | +------------------------------------------------------------------------------+ EVENT TEXT +------------------------------------------------------------------------------+ | POTENTIAL OIL SPILL TO JAMES RIVER | | | | REPORT IS BEING MADE UNDER CORE OF VIRGINIA 62.1-44.34:19, REPORTING OF | | DISCHARGE. | | | | WHILE PERFORMING WORK ON FISH FLUME PIPING AT THE LOW LEVEL INTAKE | | STRUCTURE, A BACKHOE LOST TRACTION AND SLID INTO DEEPER WATER. THE BACKHOE | | WAS IN STATE WATERS (JAMES RIVER) FOR THIS EVENT. FUEL OIL WAS REMOVED AND | | POTENTIAL OIL PATHS WERE PLUGGED TO PREVENT OIL DISCHARGE TO THE JAMES | | RIVER. ALSO AN OIL BOOM WAS PLACED AROUND THE BACKHOE. NO OIL WAS OBSERVED | | ON THE SURFACE OF THE WATER. THE STATE DEQ AND NATIONAL RESPONSE CENTER | | HAVE BEEN NOTIFIED OF THE THREAT THAT OIL WILL ENTER STATE WATERS. THIS | | REPORT IS BEING MADE UNDER CODE OF VIRGINIA 62.1-44.34:19, REPORTING OF | | DISCHARGE. | | | | THE NRC RESIDENT INSPECTOR WILL BE INFORMED OF THIS EVENT BY TH E LICENSEE. | +------------------------------------------------------------------------------+
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021