Event Notification Report for July 24, 2000

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           07/21/2000 - 07/24/2000

                              ** EVENT NUMBERS **

37181  37182  37183  

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37181       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SEABROOK                 REGION:  1  |NOTIFICATION DATE: 07/21/2000|
|    UNIT:  [1] [] []                 STATE:  NH |NOTIFICATION TIME: 11:26[EDT]|
|   RXTYPE: [1] W-4-LP                           |EVENT DATE:        07/21/2000|
+------------------------------------------------+EVENT TIME:        08:20[EDT]|
| NRC NOTIFIED BY:  GARY KILBY                   |LAST UPDATE DATE:  07/21/2000|
|  HQ OPS OFFICER:  FANGIE JONES                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |GREGORY CRANSTON     R1      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(vi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION DUE TO INADVERTENT ACTUATION OF OFFSITE SIREN           |
|                                                                              |
| During maintenance on an out-of-service emergency offsite siren, it was      |
| inadvertently actuated for about 30 seconds.  The licensee notified the      |
| Massachusetts Emergency Management Agency as well as the Newbury and Newbury |
| Port Emergency Directors.                                                    |
|                                                                              |
| The licensee notified the NRC Resident Inspector.                            |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Other Nuclear Material                           |Event Number:   37182       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  NTH CONSULTANTS                      |NOTIFICATION DATE: 07/23/2000|
|LICENSEE:  NTH CONSULTANTS                      |NOTIFICATION TIME: 18:00[EDT]|
|    CITY:  DETROIT                  REGION:  3  |EVENT DATE:        07/23/2000|
|  COUNTY:                            STATE:  MI |EVENT TIME:        12:00[EDT]|
|LICENSE#:  21-14894-01           AGREEMENT:  N  |LAST UPDATE DATE:  07/23/2000|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |MICHAEL PARKER       R3      |
|                                                |PATRICIA HOLAHAN     NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  JIM PARSONS                  |                             |
|  HQ OPS OFFICER:  DOUG WEAVER                  |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|BAB2 20.2201(a)(1)(ii)   LOST/STOLEN LNM>10X    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| STOLEN TROXLER GAUGE                                                         |
|                                                                              |
| A model 3440 Troxler moisture/density gauge was stolen along with a company  |
| truck from NTH Consultants in Detroit, MI.  The theft occurred between noon  |
| and 3:30pm on 7/23/00.  The gauge contains 8 mCi of Cs-137 and 40 mCi of     |
| Am-241.  The gauge was chained to the bed of the truck at the time of the    |
| theft.  A report is being filed with the Detroit Police Department, the      |
| Michigan State Police and the State radiation offices will be notified.      |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37183       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SURRY                    REGION:  2  |NOTIFICATION DATE: 07/23/2000|
|    UNIT:  [1] [2] []                STATE:  VA |NOTIFICATION TIME: 20:42[EDT]|
|   RXTYPE: [1] W-3-LP,[2] W-3-LP                |EVENT DATE:        07/23/2000|
+------------------------------------------------+EVENT TIME:        20:10[EDT]|
| NRC NOTIFIED BY:  RAWLEIGH DILLARD             |LAST UPDATE DATE:  07/23/2000|
|  HQ OPS OFFICER:  DOUG WEAVER                  +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |BRIAN BONSER         R2      |
|10 CFR SECTION:                                 |                             |
|AARC 50.72(b)(1)(v)      OTHER ASMT/COMM INOP   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| LOSS OF PLANT COMPUTER                                                       |
|                                                                              |
| "At 1910 hours on 7/23/00, the Safety Parameter Display System (SPDS)        |
| portion of the Emergency Response Facility Computer System (ERFCS) was noted |
| to be inoperable, due to all outputs being displayed in magenta color.       |
| Several attempts were made to reboot the system, but were unsuccessful.  The |
| air conditioning system for the Technical Support Center (TSC) computer room |
| (which houses the ERFCS) had failed earlier in the day, and the air          |
| conditioning system was secured to perform repairs.  Portable cooling fans   |
| were being used to cool the TSC computer room and the room temperature had   |
| stayed at about 80 degrees F.  The system must be secured if temperature     |
| rises above 85 degrees F.                                                    |
|                                                                              |
| "Repairs to the TSC computer room air conditioning system are continuing at  |
| this time.  A return to service time for the SPDS portion of the ERFCS has   |
| not been determined at this time."                                           |
|                                                                              |
| The licensee will notify the NRC resident inspector.                         |
+------------------------------------------------------------------------------+