Event Notification Report for July 20, 2000
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
07/19/2000 - 07/20/2000
** EVENT NUMBERS **
37107 37158 37178
!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37107 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: DRESDEN REGION: 3 |NOTIFICATION DATE: 06/22/2000|
| UNIT: [] [2] [] STATE: IL |NOTIFICATION TIME: 18:07[EDT]|
| RXTYPE: [1] GE-1,[2] GE-3,[3] GE-3 |EVENT DATE: 06/22/2000|
+------------------------------------------------+EVENT TIME: 14:07[CDT]|
| NRC NOTIFIED BY: BORING |LAST UPDATE DATE: 07/19/2000|
| HQ OPS OFFICER: CHAUNCEY GOULD +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |ROGER LANKSBURY R3 |
|10 CFR SECTION: | |
|AIND 50.72(b)(2)(iii)(D) ACCIDENT MITIGATION | |
|NLCO TECH SPEC LCO A/S | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
| | |
|2 N Y 100 Power Operation |100 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| THE PLANT ENTERED A 14 DAY LCO ACTION STATEMENT DUE TO HIGH PRESSURE COOLANT |
| INJECTION (HPCI) SYSTEM BEING DECLARED INOPERABLE. |
| |
| During routine surveillance testing of the Containment Cooling Water System |
| (CCWS), required system flow through the HPCI Room Cooler could not be |
| obtained due to leakage past 2-3999-252 check valve. |
| |
| With the HPCI Room Cooler inoperable, the HPCI System was declared |
| INOPERABLE, a 14 day LCO Action Statement was entered, and an action request |
| for repair of the 2-3999-252 valve was submitted. |
| |
| The NRC Resident Inspector was notified by the licensee. |
| |
| * * * UPDATE AT 1917 ON 07/19/00 BY MARK RUNION TO JOLLIFFE * * * |
| |
| Upon further review of this event by Dresden Operations and Engineering |
| Department personnel, the licensee determined that with the HPCI Room Cooler |
| blower available, even without CCWS flow to the HPCI Room Cooler, the HPCI |
| System will perform its required function and remain operable. Thus, the |
| HPCI System was not inoperable at the time of the notification of this event |
| and therefore, this event is not reportable to the NRC. Based on this, the |
| licensee desires to retract this event. |
| |
| The licensee notified the NRC Resident Inspector. The NRC Operations |
| Officer notified the R3DO Mike Parker. |
+------------------------------------------------------------------------------+
!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37158 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: TURKEY POINT REGION: 2 |NOTIFICATION DATE: 07/10/2000|
| UNIT: [3] [4] [] STATE: FL |NOTIFICATION TIME: 17:28[EDT]|
| RXTYPE: [3] W-3-LP,[4] W-3-LP |EVENT DATE: 07/10/2000|
+------------------------------------------------+EVENT TIME: 10:38[EDT]|
| NRC NOTIFIED BY: JAMES RUSSELL |LAST UPDATE DATE: 07/19/2000|
| HQ OPS OFFICER: BOB STRANSKY +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |GEORGE BELISLE R2 |
|10 CFR SECTION: | |
|HFIT 26.73 FITNESS FOR DUTY | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|3 N Y 100 Power Operation |100 Power Operation |
|4 N Y 100 Power Operation |100 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| FITNESS FOR DUTY REPORT |
| |
| A licensed training supervisor tested positive for alcohol use during a |
| random drug and alcohol test. The individual's access has been suspended and |
| the licensee will review the individual's work for the past 90 days. The NRC |
| resident inspector has been informed of this event by the licensee. |
| |
| * * * RETRACTION ON 07/19/00 AT 1122 ET BY STEWART TAKEN BY MACKINNON * * * |
| |
| After discussions with NRC Region 2 it was determined that the above |
| reported event did not have to be reported and is being withdrawn. The |
| individual was not a supervisor at the time of the event. This report will |
| be reported on the licensee's Semi - Annual Fitness for Duty Report. NRC |
| R2DO (Bonser) notified. |
| |
| The NRC Resident Inspector was notified of this update by the licensee. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37178 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: INDIAN POINT REGION: 1 |NOTIFICATION DATE: 07/20/2000|
| UNIT: [] [3] [] STATE: NY |NOTIFICATION TIME: 04:28[EDT]|
| RXTYPE: [2] W-4-LP,[3] W-4-LP |EVENT DATE: 07/20/2000|
+------------------------------------------------+EVENT TIME: 03:52[EDT]|
| NRC NOTIFIED BY: TESORIERO |LAST UPDATE DATE: 07/20/2000|
| HQ OPS OFFICER: BOB STRANSKY +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |GREGORY CRANSTON R1 |
|10 CFR SECTION: | |
|AOUT 50.72(b)(1)(ii)(B) OUTSIDE DESIGN BASIS | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
| | |
|3 N Y 100 Power Operation |100 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| UNIT OUTSIDE OF DESIGN BASIS |
| |
| "On July 20, 2000 at 0352 hours a Reactor Coolant system leakrate of 0.30 |
| gpm was calculated. Currently the Charging and Letdown systems are isolated |
| for maintenance. Investigation revealed the leakage being from the Excess |
| Letdown system to the systems isolated for maintenance, which are located |
| outside Containment. This leakrate exceeds the limit of 0.68 gph outside |
| Containment and therefore is a condition outside the design basis of the |
| plant. The Control Room Ventilation system is inoperable and a 72 hour |
| limiting condition of operation has been entered." |
| |
| The NRC resident inspector will be informed of this event by the licensee. |
+------------------------------------------------------------------------------+