The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.
Event Notification Report for July 19, 2000
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
07/18/2000 - 07/19/2000
** EVENT NUMBERS **
37174 37175 37176 37177
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37174 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: QUAD CITIES REGION: 3 |NOTIFICATION DATE: 07/18/2000|
| UNIT: [] [2] [] STATE: IL |NOTIFICATION TIME: 08:29[EDT]|
| RXTYPE: [1] GE-3,[2] GE-3 |EVENT DATE: 07/18/2000|
+------------------------------------------------+EVENT TIME: 05:48[CDT]|
| NRC NOTIFIED BY: NORTON |LAST UPDATE DATE: 07/18/2000|
| HQ OPS OFFICER: CHAUNCEY GOULD +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |MICHAEL PARKER R3 |
|10 CFR SECTION: | |
|ARPS 50.72(b)(2)(ii) RPS ACTUATION | |
|AESF 50.72(b)(2)(ii) ESF ACTUATION | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
| | |
|2 A/R Y 100 Power Operation |0 Hot Standby |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| REACTOR SCRAM FROM 100% POWER DUE TO A GENERATOR LOAD REJECT FOLLOWED BY |
| TURBINE TRIP. |
| |
| THE UNIT 2 REACTOR SCRAM WAS RECEIVED DUE TO A GENERATOR LOAD REJECT |
| APPARENTLY CAUSED BY A DISTURBANCE ON THE 345 KV SYSTEM. ALL RODS FULLY |
| INSERTED, NO INJECTION INITIATED AND NO SAFETY/RELIEF VALVES LIFTED. THEY |
| ALSO HAD GROUP 2 AND GROUP 3 ISOLATIONS, AS EXPECTED, DUE TO A REACTOR WATER |
| LEVEL LOW SIGNAL FOLLOWING THE REACTOR SCRAM. THE UNIT 2 AND SHARED |
| EMERGENCY DIESEL GENERATORS AUTOSTARTED AND RAN UNLOADED AS THE RESULT OF |
| THE AUTOMATIC BUS TRANSFERS. |
| |
| UNIT 1 REMAINS AT 100% POWER WITH ITS RESERVE AUXILIARY TRANSFORMER |
| DE-ENERGIZED AND UNIT 2 IS IN MODE 3 WITH ITS NORMAL WATER LEVEL BAND. THE |
| CAUSE OF THIS EVENT, WHICH PROBABLY OCCURRED OUTSIDE THE YARD, IS STILL |
| BEING INVESTIGATED. |
| |
| THE SECTIONS OF THE RING BUS THAT THEY LOST LEFT UNIT 1 WITHOUT ITS RESERVE |
| AUXILIARY TRANSFORMER, SO IT IS RUNNING OFF ITS AUXILIARY TRANSFORMER. |
| |
| THE NRC RESIDENT INSPECTOR WAS NOTIFIED BY THE LICENSEE. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Hospital |Event Number: 37175 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: GRAND VIEW HOSPITAL |NOTIFICATION DATE: 07/18/2000|
|LICENSEE: GRAND VIEW HOSPITAL |NOTIFICATION TIME: 12:57[EDT]|
| CITY: SELLERSVILLE REGION: 1 |EVENT DATE: 06/30/2000|
| COUNTY: STATE: PA |EVENT TIME: 11:00[EDT]|
|LICENSE#: 37-13187-02 AGREEMENT: N |LAST UPDATE DATE: 07/18/2000|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |GREGORY CRANSTON R1 |
| |DON COOL NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: DAVE LIGHTFOOT | |
| HQ OPS OFFICER: DICK JOLLIFFE | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|BAB2 20.2201(a)(1)(ii) LOST/STOLEN LNM>10X | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| - GRAND VIEW HOSPITAL, SELLERSVILLE, PA, MISSING TWO 0.38 MILLICURIE I-125 |
| SEEDS - |
| |
| At 1100 on 06/30/00, Grand View Hospital, Sellersville, PA, received a |
| shipment of two vials of I-125 seeds from Imagyn Medical Technologies, |
| Lenexa, KS. The shipping papers stated that the first vial contained one |
| calibration seed and the second vial contained 81 seeds. Each seed |
| contained 0.38 millicuries of I-125. However, when hospital personnel |
| opened the vials, the second vial contained only 80 seeds instead of 81 |
| seeds. Hospital personnel notified Imagyn, the shipper, International |
| Isotopes, Benton, TX, and NRC Region 1 (Neelam Bhalla). Imagyn started an |
| investigation into the missing seed. |
| |
| On 07/17/00, Grand View Hospital received another shipment of two vials of |
| I-125 seeds from Imagyn. The shipping papers stated that the first vial |
| contained one calibration seed and the second vial contained 94 seeds. Each |
| seed contained 0.38 millicuries of I-125. However, when hospital personnel |
| opened the shipping container, the container contained only one vial, the |
| one with the calibration seed. |
| |
| Hospital personnel notified Imagyn and requested an emergency shipment of |
| the missing vial containing 94 seeds. |
| |
| At 0300 on 07/18/00, hospital personnel received the emergency shipment of |
| one vial of I-125 seeds from Imagyn. The shipping papers stated that the |
| vial contained 94 seeds. However, when hospital personnel opened the vial, |
| it contained only 93 seeds instead of 94 seeds. Hospital personnel notified |
| Imagyn and NRC Region 1 (Neelam Bhalla). |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37176 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: DUANE ARNOLD REGION: 3 |NOTIFICATION DATE: 07/18/2000|
| UNIT: [1] [] [] STATE: IA |NOTIFICATION TIME: 14:17[EDT]|
| RXTYPE: [1] GE-4 |EVENT DATE: 07/18/2000|
+------------------------------------------------+EVENT TIME: 12:12[CDT]|
| NRC NOTIFIED BY: BOB MURRELL |LAST UPDATE DATE: 07/18/2000|
| HQ OPS OFFICER: DICK JOLLIFFE +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |MICHAEL PARKER R3 |
|10 CFR SECTION: | |
|AESF 50.72(b)(2)(ii) ESF ACTUATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| - UNEXPECTED ESF ACTUATION DURING PREPLANNED MAINTENANCE ACTIVITIES - |
| |
| At 1212 CDT on 07/18/00, during preplanned maintenance activities on the 'B' |
| standby gas treatment system logic, an unexpected, invalid ESF actuation |
| occurred. Specifically, a planned fuse removal resulted in an unexpected |
| isolation of a containment nitrogen makeup valve and a recirc minipurge |
| valve. All isolations were completed, as designed. The licensee plans to |
| restore all components to their normal positions prior to completing the |
| maintenance activities. |
| |
| The licensee notified the NRC Resident Inspector. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 37177 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: GINNA REGION: 1 |NOTIFICATION DATE: 07/18/2000|
| UNIT: [1] [] [] STATE: NY |NOTIFICATION TIME: 19:40[EDT]|
| RXTYPE: [1] W-2-LP |EVENT DATE: 07/18/2000|
+------------------------------------------------+EVENT TIME: 18:45[EDT]|
| NRC NOTIFIED BY: DOUG GOMEZ/RON TEED |LAST UPDATE DATE: 07/18/2000|
| HQ OPS OFFICER: DICK JOLLIFFE +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |GREGORY CRANSTON R1 |
|10 CFR SECTION: | |
|DDDD 73.71 UNSPECIFIED PARAGRAPH | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 100 Power Operation |100 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| PHYSICAL SECURITY EVENT - |
| |
| ATTEMPTED INTRODUCTION OF CONTRABAND INTO THE PLANT PROTECTED AREA. |
| COMPENSATORY MEASURES WERE IMMEDIATELY TAKEN UPON DISCOVERY. THE LICENSEE |
| PLANS TO NOTIFY THE NRC RESIDENT INSPECTOR. CONTACT THE NRC OPERATIONS |
| OFFICER FOR ADDITIONAL DETAILS. |
+------------------------------------------------------------------------------+
Page Last Reviewed/Updated Thursday, March 25, 2021
Page Last Reviewed/Updated Thursday, March 25, 2021