Skip to main content

Alert

Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for July 11, 2000

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           07/10/2000 - 07/11/2000

                              ** EVENT NUMBERS **

37154  37155  37156  37157  37158  37159  

+------------------------------------------------------------------------------+
|Other Nuclear Material                           |Event Number:   37154       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  U.S. ARMY                            |NOTIFICATION DATE: 07/10/2000|
|LICENSEE:  U.S. ARMY                            |NOTIFICATION TIME: 09:26[EDT]|
|    CITY:  ROCK ISLAND              REGION:  3  |EVENT DATE:        07/08/2000|
|  COUNTY:                            STATE:  IL |EVENT TIME:        12:17[CDT]|
|LICENSE#:  12-00722-06           AGREEMENT:  Y  |LAST UPDATE DATE:  07/10/2000|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |MICHAEL JORDAN       R3      |
|                                                |DON COOL             NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  JEFF HAVENNER                |                             |
|  HQ OPS OFFICER:  DOUG WEAVER                  |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|BAB2 20.2201(a)(1)(ii)   LOST/STOLEN LNM>10X    |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| STOLEN CHEMICAL AGENT DETECTOR                                               |
|                                                                              |
| AN M43A1 CHEMICAL AGENT DETECTOR WAS STOLEN FROM THE TWIN BRIDGES TRAINING   |
| AREA IN THE REPUBLIC OF KOREA DURING A RECENT EXERCISE.  THE DETECTOR        |
| CONTAINS 250 �Ci of Am-241.  THE ARMY HAS NOTIFIED THE REPUBLIC OF KOREA.    |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37155       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: HATCH                    REGION:  2  |NOTIFICATION DATE: 07/10/2000|
|    UNIT:  [1] [] []                 STATE:  GA |NOTIFICATION TIME: 11:41[EDT]|
|   RXTYPE: [1] GE-4,[2] GE-4                    |EVENT DATE:        07/10/2000|
+------------------------------------------------+EVENT TIME:        10:51[EDT]|
| NRC NOTIFIED BY:  FRANK GORLEY                 |LAST UPDATE DATE:  07/10/2000|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |GEORGE BELISLE       R2      |
|10 CFR SECTION:                                 |                             |
|ARPS 50.72(b)(2)(ii)     RPS ACTUATION          |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     A/R        Y       100      Power Operation  |0        Hot Shutdown     |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| UNIT 1 EXPERIENCED A REACTOR SCRAM FOLLOWING TURBINE TRIP AFTER RECEIVING A  |
| TURBINE ALARM                                                                |
|                                                                              |
| UNIT 1 RECEIVED A TURBINE SUPERVISORY EQUIPMENT FAILURE ALARM FOLLOWED BY A  |
| TURBINE TRIP.  THE LOWEST INDICATED REACTOR VESSEL WATER LEVEL (RVWL)  WAS   |
| +18 INCHES. THE RVWL WAS RECOVERED TO NORMAL. BY REACTOR FEED PUMPS.         |
| INDICATION SHOWS THAT NINE (9) SAFETY RELIEF VALVES (SRVs) OPENED DURING     |
| THIS TRANSIENT.  PRELIMINARY INDICATION SHOWS HIGH VIBRATION ON #10          |
| GENERATOR BEARING.  THE LICENSEE SUSPECTS EITHER A BAD PROBE,  WIRING OR     |
| ELECTRONIC CARD PROBLEM.                                                     |
|                                                                              |
| UNIT 1 IS CURRENTLY STABLE WITH "A" REACTOR FEED PUMP SUPPLY WATER TO THE    |
| REACTOR VESSEL AND STEAM REMOVING DECAY HEAT VIA THE TURBINE BYPASS TO THE   |
| MAIN CONDENSER.  ALL SRVs RESEATED AND THERE IS NO SAFETY RELATED EQUIPMENT  |
| OUT OF SERVICE AT THIS TIME.                                                 |
|                                                                              |
| THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR.                            |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37156       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: CALVERT CLIFFS           REGION:  1  |NOTIFICATION DATE: 07/10/2000|
|    UNIT:  [1] [2] []                STATE:  MD |NOTIFICATION TIME: 13:37[EDT]|
|   RXTYPE: [1] CE,[2] CE                        |EVENT DATE:        07/10/2000|
+------------------------------------------------+EVENT TIME:        13:00[EDT]|
| NRC NOTIFIED BY:  TIM RIDDY                    |LAST UPDATE DATE:  07/10/2000|
|  HQ OPS OFFICER:  BOB STRANSKY                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |RICHARD CONTE        R1      |
|10 CFR SECTION:                                 |                             |
|APRE 50.72(b)(2)(vi)     OFFSITE NOTIFICATION   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| OFFSITE NOTIFICATION TO STATE REGARDING ONSITE WATER QUALITY                 |
|                                                                              |
| Results of domestic water samples taken on 7/6/00 indicate the presence of   |
| fecal coliform. The licensee will be making a notification to the State of   |
| Maryland regarding the results. The NRC resident inspector has been informed |
| of this notification by the licensee.                                        |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37157       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: TURKEY POINT             REGION:  2  |NOTIFICATION DATE: 07/10/2000|
|    UNIT:  [3] [4] []                STATE:  FL |NOTIFICATION TIME: 17:28[EDT]|
|   RXTYPE: [3] W-3-LP,[4] W-3-LP                |EVENT DATE:        07/10/2000|
+------------------------------------------------+EVENT TIME:        13:30[EDT]|
| NRC NOTIFIED BY:  JAMES RUSSELL                |LAST UPDATE DATE:  07/10/2000|
|  HQ OPS OFFICER:  BOB STRANSKY                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |GEORGE BELISLE       R2      |
|10 CFR SECTION:                                 |                             |
|HFIT 26.73               FITNESS FOR DUTY       |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|3     N          Y       100      Power Operation  |100      Power Operation  |
|4     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| FITNESS FOR DUTY REPORT                                                      |
|                                                                              |
| A contract supervisor tested positive for cocaine use during a random drug   |
| and alcohol test. The individual's access has been suspended and the         |
| licensee will review the individual's work for the past 90 days. The NRC     |
| resident inspector has been informed of this event by the licensee.          |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37158       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: TURKEY POINT             REGION:  2  |NOTIFICATION DATE: 07/10/2000|
|    UNIT:  [3] [4] []                STATE:  FL |NOTIFICATION TIME: 17:28[EDT]|
|   RXTYPE: [3] W-3-LP,[4] W-3-LP                |EVENT DATE:        07/10/2000|
+------------------------------------------------+EVENT TIME:        10:38[EDT]|
| NRC NOTIFIED BY:  JAMES RUSSELL                |LAST UPDATE DATE:  07/10/2000|
|  HQ OPS OFFICER:  BOB STRANSKY                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |GEORGE BELISLE       R2      |
|10 CFR SECTION:                                 |                             |
|HFIT 26.73               FITNESS FOR DUTY       |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|3     N          Y       100      Power Operation  |100      Power Operation  |
|4     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| FITNESS FOR DUTY REPORT                                                      |
|                                                                              |
| A licensed training supervisor tested positive for alcohol use during a      |
| random drug and alcohol test. The individual's access has been suspended and |
| the licensee will review the individual's work for the past 90 days. The NRC |
| resident inspector has been informed of this event by the licensee.          |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|General Information or Other                     |Event Number:   37159       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG:  WA DIVISION OF RADIATION PROTECTION  |NOTIFICATION DATE: 07/10/2000|
|LICENSEE:  EDAX, INC.                           |NOTIFICATION TIME: 20:10[EDT]|
|    CITY:  KENNEWICK                REGION:  4  |EVENT DATE:        06/22/2000|
|  COUNTY:                            STATE:  WA |EVENT TIME:             [PDT]|
|LICENSE#:  WN-I0282-1            AGREEMENT:  Y  |LAST UPDATE DATE:  07/10/2000|
|  DOCKET:                                       |+----------------------------+
|                                                |PERSON          ORGANIZATION |
|                                                |LINDA HOWELL         R4      |
|                                                |JOHN GREEVES         NMSS    |
+------------------------------------------------+                             |
| NRC NOTIFIED BY:  TERRY FRAZEE                 |                             |
|  HQ OPS OFFICER:  BOB STRANSKY                 |                             |
+------------------------------------------------+                             |
|EMERGENCY CLASS:          N/A                   |                             |
|10 CFR SECTION:                                 |                             |
|NAGR                     AGREEMENT STATE        |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| AGREEMENT STATE REPORT                                                       |
|                                                                              |
| "Date of event: June 22, 2000                                                |
| "Location of Event: Rochester, NY                                            |
|                                                                              |
| "During a device sales demonstration the potential customer happened to      |
| measure higher than expected dose rates on a MAP-4 series model FA4C2        |
| portable x-ray fluorescence device.  It was later determined that the        |
| source, 125 millicuries of Am-241, had fallen out of the source block but    |
| was still contained within the device, although unshielded.  The device was  |
| shielded and subsequently returned to the manufacturer, EDAX, Inc.  To       |
| compound matters, the device was being referred to as a model 'CT3000' by    |
| the sales demonstrator and the initial reporting of the incident by the      |
| state of New York was believed to concern the recently approved, but         |
| unrelated, CT5000 series devices.  On June 28, 2000, the EDAX RSO responded  |
| to the state of Washington Department of Health that EDAX had manufactured   |
| four MAP-4 (FA4C2) devices for research and development with source blocks   |
| that had not been approved by the department for general production.  One of |
| the research devices had been mistakenly assembled with an experimental      |
| source block design that was previously rejected as unsatisfactory.  This    |
| device was involved in the incident in New York State while being tested for |
| effectiveness and market potential.                                          |
|                                                                              |
| "EDAX has accounted for all its experimental source blocks and has removed   |
| the one faulty block from the device and marked it so that it can not be     |
| used in the future.  The remaining R&D devices will be surveyed whenever     |
| used.  Although this manufacturing error did not involve the production of   |
| devices intended for sale to licensees, staff from the Division of Radiation |
| Protection will be reviewing the manufacturer's quality control process as   |
| well as model designation practices.                                         |
|                                                                              |
| "What is the notification or reporting criteria involved?  WAC 246-221-250;  |
| re: Equipment failure.                                                       |
|                                                                              |
| "Activity and isotope(s) involved: 125 mCi Am-241 source, serial number      |
| 7887LQ.                                                                      |
|                                                                              |
| "Device (HDR, etc.) Mfg., Model; computer code:  EDAX, Inc., MAP-4 series    |
| model FA4C2 x-ray fluorescence device, serial number 1525."                  |
+------------------------------------------------------------------------------+


Page Last Reviewed/Updated Wednesday, March 24, 2021

Page Last Reviewed/Updated Wednesday, March 24, 2021