Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for June 29, 2000

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           06/28/2000 - 06/29/2000

                              ** EVENT NUMBERS **

37127  37128  37129  37130  

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37127       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: GINNA                    REGION:  1  |NOTIFICATION DATE: 06/28/2000|
|    UNIT:  [1] [] []                 STATE:  NY |NOTIFICATION TIME: 13:19[EDT]|
|   RXTYPE: [1] W-2-LP                           |EVENT DATE:        06/28/2000|
+------------------------------------------------+EVENT TIME:        12:50[EDT]|
| NRC NOTIFIED BY:  ROY GILLOW                   |LAST UPDATE DATE:  06/28/2000|
|  HQ OPS OFFICER:  FANGIE JONES                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |SCOTT MORRIS         R1      |
|10 CFR SECTION:                                 |                             |
|AESS 50.72(b)(1)(v)      EMERGENCY SIREN INOP   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| MONTHLY SIREN TEST FAILED                                                    |
|                                                                              |
| On 6/26/00 at 0915 EDT, the offsite emergency siren silent test failed at    |
| both the Wayne County EOC and the 911  actuation center.  Upon arrival of    |
| maintenance personnel, the test was completed satisfactorily.  Root cause    |
| for the test failure has not been determined.                                |
|                                                                              |
| The licensee was not notified until 1250 EDT on 6/28/00.  There is an        |
| investigation in progress to determine the root cause of the test failure.   |
|                                                                              |
|                                                                              |
| The licensee notified the NRC Resident Inspector and the local authorities.  |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37128       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SEQUOYAH                 REGION:  2  |NOTIFICATION DATE: 06/28/2000|
|    UNIT:  [1] [2] []                STATE:  TN |NOTIFICATION TIME: 21:08[EDT]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        06/28/2000|
+------------------------------------------------+EVENT TIME:        20:20[EDT]|
| NRC NOTIFIED BY:  CHRIS REEVES                 |LAST UPDATE DATE:  06/28/2000|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |CAUDLE JULIAN        R2      |
|10 CFR SECTION:                                 |                             |
|DDDD 73.71               UNSPECIFIED PARAGRAPH  |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       100      Power Operation  |100      Power Operation  |
|2     N          Y       100      Power Operation  |100      Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| SECURITY REPORT                                                              |
|                                                                              |
| SAFEGUARDS SYSTEM DEGRADATION RELATED TO PERIMETER MONITORING.  IMMEDIATE    |
| COMPENSATORY MEASURES NOT FULLY IMPLEMENTED WITHIN THE TIME REQUIRED BY THE  |
| SECURITY PLAN.  COMPENSATORY MEASURES NOW ARE FULLY IMPLEMENTED.             |
|                                                                              |
| THE LICENSEE WILL INFORM THE NRC RESIDENT INSPECTOR.  CONTACT THE            |
| HEADQUARTERS OPERATIONS OFFICER FOR ADDITIONAL DETAILS.                      |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37129       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: COOK                     REGION:  3  |NOTIFICATION DATE: 06/28/2000|
|    UNIT:  [] [2] []                 STATE:  MI |NOTIFICATION TIME: 22:31[EDT]|
|   RXTYPE: [1] W-4-LP,[2] W-4-LP                |EVENT DATE:        06/28/2000|
+------------------------------------------------+EVENT TIME:        22:24[EDT]|
| NRC NOTIFIED BY:  STEVE CHERBA                 |LAST UPDATE DATE:  06/28/2000|
|  HQ OPS OFFICER:  STEVE SANDIN                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |MELVYN LEACH         R3      |
|10 CFR SECTION:                                 |                             |
|ASHU 50.72(b)(1)(i)(A)   PLANT S/D REQD BY TS   |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|                                                   |                          |
|2     N          Y       79       Power Operation  |79       Power Operation  |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| UNIT 2 COMMENCED A TECH SPEC REQUIRED SHUTDOWN AFTER TWO IRPIs IN THE SAME   |
| GROUP WERE DECLARED INOPERABLE                                               |
|                                                                              |
| The following information was received by fax:                               |
|                                                                              |
| Notification time: 2231 hrs EDT 6-28-00                                      |
| Event Notification No.: 37129                                                |
| NRC Contact: Steve Sandin                                                    |
| Cook Caller: SJ Cherba                                                       |
| Power Level Prior to event: 79.6%                                            |
|                                                                              |
| Notification Script:                                                         |
|                                                                              |
| This is Steve Cherba at the Cook Unit 2 Nuclear Plant making a one hour,     |
| non-emergency notification for initiation of a nuclear plant shutdown        |
| required by Technical Specifications in accordance with                      |
| 10CFR50.72(b)(1)(i)(A). The shutdown was initiated to comply with TS 3.0.3 @ |
| 2224 hrs EDT on 6-28-00. The TS 3.0.3 one hour limit for initiating a        |
| shutdown would have expired @ 2228 hrs EDT on 6-28-00. TS 3.0.3 was entered  |
| when it was discovered that the unit had two Individual Rod Position         |
| Indicators (IRPIs ) in one group that were INOPERABLE, exceeding the         |
| allowable actions of TS 3.1.3.2 a., which only allows a maximum of one       |
| INOPERABLE IRPI per rod group. These IRPIs became INOPERABLE when, without   |
| any associated rod movement, the indicated rod position drifted above the    |
| allowable rod deviation limit. Instrument technicians are in the process of  |
| calibrating these IRPIs and we expect to exit this situation within two      |
| hours without completing the shutdown.                                       |
|                                                                              |
| The control rod IRPIs were H12 & M8, both associated with Control Bank D,    |
| Group 2.                                                                     |
|                                                                              |
| Post Script to this notification:                                            |
|                                                                              |
| The two IRPIs were calibrated for drift caused by the RCS temperature        |
| increase associated with the unit power increase following the outage and    |
| are within allowable limits and OPERABLE @ 2250 hrs EDT 6-28-00. The         |
| shutdown was halted and power stabilized @ 2250 hrs EDT 6-28-00. NRC         |
| resident personnel were informed of the condition and shutdown at 2230 hrs   |
| EDT ( J Maynen) & 2240 hrs EDT ( B Bartlett). Power Level when shutdown      |
| stopped: 78.9%.                                                              |
+------------------------------------------------------------------------------+

+------------------------------------------------------------------------------+
|Fuel Cycle Facility                              |Event Number:   37130       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: SIEMENS POWER CORPORATION            |NOTIFICATION DATE: 06/29/2000|
|   RXTYPE: URANIUM FUEL FABRICATION             |NOTIFICATION TIME: 00:55[EDT]|
| COMMENTS: LEU CONVERSION (UF6 to UO2)          |EVENT DATE:        06/28/2000|
|           FABRICATION & SCRAP RECOVERY         |EVENT TIME:        21:15[PDT]|
|           COMMERICAL LWR FUEL                  |LAST UPDATE DATE:  06/29/2000|
|    CITY:  RICHLAND                 REGION:  4  +-----------------------------+
|  COUNTY:  BENTON                    STATE:  WA |PERSON          ORGANIZATION |
|LICENSE#:  SNM-1227              AGREEMENT:  Y  |GAIL GOOD            R4      |
|  DOCKET:  07001257                             |JOHN HICKEY          NMSS    |
+------------------------------------------------+CHARLES MILLER       IRO     |
| NRC NOTIFIED BY:  LOREN MAAS                   |PETER PRESCOTT       RCT     |
|  HQ OPS OFFICER:  DOUG WEAVER                  |GABRINI              DOE     |
+------------------------------------------------+TURMAN               NRC     |
|EMERGENCY CLASS:          ALE                   |                             |
|10 CFR SECTION:                                 |                             |
|AAEC 50.72 (a) (1) (I)   EMERGENCY DECLARED     |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
|                                                |                             |
+------------------------------------------------------------------------------+

                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| ALERT DECLARED - OFFSITE FIRE                                                |
|                                                                              |
| RANGE FIRE ON AND ADJACENT TO THE HANFORD NUCLEAR RESERVATION HAS PROMPTED   |
| BENTON COUNTY EMERGENCY MANAGEMENT, IN CONJUNCTION WITH LOCAL LAW            |
| ENFORCEMENT, TO REQUIRE A PRECAUTIONARY EVACUATION OF THE HORN RAPIDS        |
| TRIANGLE INDUSTRIAL AREA IN WHICH THE SIEMENS FUEL FABRICATION PLANT IS      |
| LOCATED.   THE PLANT PRODUCTION HAS BEEN SHUT DOWN.  ESSENTIAL PLANT         |
| PERSONNEL ARE ONSITE.   BASED ON DISTANCE AND CURRENT WIND DIRECTION, THE    |
| PLANT IS NOT THREATENED.                                                     |
|                                                                              |
| * * * UPDATE AT 0451 ON 6/29/00 BY PROBASCO, RECEIVED BY WEAVER * * *        |
|                                                                              |
| THE ALERT WAS TERMINATED AT 0150 PDT BECAUSE THE FIRE HAS MOVED FURTHER AWAY |
| FROM THE SITE AND IS CONTINUING TO MOVE IN THAT DIRECTION.                   |
|                                                                              |
| NRC NOTIFIED RDO (GOOD); EO (HICKEY); IRO (MILLER); FEMA (STEINDURF); DOE    |
| (STAMBAUGH); NRC (TURMAN)                                                    |
+------------------------------------------------------------------------------+