Due to a lapse in appropriations, the NRC has ceased normal operations. However, excepted and exempted activities necessary to maintain critical health and safety functions—as well as essential progress on designated critical activities, including those specified in Executive Order 14300—will continue, consistent with the OMB-Approved NRC Lapse Plan.

Event Notification Report for June 13, 2000

                    U.S. Nuclear Regulatory Commission
                              Operations Center

                              Event Reports For
                           06/12/2000 - 06/13/2000

                              ** EVENT NUMBERS **

37077  

+------------------------------------------------------------------------------+
|Power Reactor                                    |Event Number:   37077       |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: KEWAUNEE                 REGION:  3  |NOTIFICATION DATE: 06/12/2000|
|    UNIT:  [1] [] []                 STATE:  WI |NOTIFICATION TIME: 11:50[EDT]|
|   RXTYPE: [1] W-2-LP                           |EVENT DATE:        06/12/2000|
+------------------------------------------------+EVENT TIME:        09:15[CDT]|
| NRC NOTIFIED BY:  GARY HARRINGTON              |LAST UPDATE DATE:  06/12/2000|
|  HQ OPS OFFICER:  BOB STRANSKY                 +-----------------------------+
+------------------------------------------------+PERSON          ORGANIZATION |
|EMERGENCY CLASS:          N/A                   |DAVID HILLS          R3      |
|10 CFR SECTION:                                 |                             |
|ADAS 50.72(b)(2)(i)      DEG/UNANALYZED COND    |                             |
|AIND 50.72(b)(2)(iii)(D) ACCIDENT MITIGATION    |                             |
|                                                |                             |
|                                                |                             |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR|   INIT RX MODE  |CURR PWR|  CURR RX MODE   |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1     N          Y       71       Power Operation  |71       Power Operation  |
|                                                   |                          |
|                                                   |                          |
+------------------------------------------------------------------------------+
                                   EVENT TEXT                                   
+------------------------------------------------------------------------------+
| INADEQUATE SERVICE WATER SYSTEM FLOW TO EDGs (HISTORICAL REPORT)             |
|                                                                              |
| "On June 2, 2000, Kewaunee completed a scheduled refueling outage. During    |
| the outage, comprehensive flow data was measured on the plant's service      |
| water system. Subsequent analysis of the flow data revealed that for less    |
| than one hour on August 8, 1991, both of the redundant diesel generators     |
| could have had cooling water flow below design basis post-accident           |
| requirements. The cause of the condition is a combination of elevated        |
| cooling water temperatures, conservative calculation assumptions using       |
| recent data, and a previously unidentified design problem that results in    |
| reduced flow through the diesel coolers. The design problem occurs due to    |
| system backpressure caused by the diesels' cooling water discharges being    |
| connected to a common header. During the outage, the diesel generator heat   |
| exchangers were replaced for reasons unrelated to this report. The new heat  |
| exchangers' increased capacity precludes recurrence."                        |
|                                                                              |
| The NRC resident inspector has been informed of this event by the licensee.  |
+------------------------------------------------------------------------------+


Page Last Reviewed/Updated Wednesday, March 24, 2021