The NRC is modernizing nrc.gov with an updated design and improved navigation to enhance usability. We are committed to a smooth transition and will work to minimize any disruption. The site may be briefly unavailable at times during launch. Thank you for your patience.
Event Notification Report for April 28, 2000
U.S. Nuclear Regulatory Commission
Operations Center
Event Reports For
04/27/2000 - 04/28/2000
** EVENT NUMBERS **
36809 36924 36934 36935 36936 36937
+------------------------------------------------------------------------------+
|Other Nuclear Material |Event Number: 36809 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: U.S. ARMY |NOTIFICATION DATE: 03/17/2000|
|LICENSEE: U.S. ARMY |NOTIFICATION TIME: 15:53[EST]|
| CITY: ROCK ISLAND REGION: 3 |EVENT DATE: 03/17/2000|
| COUNTY: STATE: IL |EVENT TIME: 12:00[CST]|
|LICENSE#: 12-00722-06 AGREEMENT: Y |LAST UPDATE DATE: 04/27/2000|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |JOHN JACOBSON R3 |
| |AL BELISLE R2 |
+------------------------------------------------+DON COOL NMSS |
| NRC NOTIFIED BY: JEFF HAVENNER |CHARLES MILLER IRO |
| HQ OPS OFFICER: LEIGH TROCINE | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|BAB1 20.2201(a)(1)(i) LOST/STOLEN LNM>1000X | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| DISCOVERY THAT AN M43A1 CHEMICAL AGENT DETECTOR CELL MODULE CONTAINING 250 |
| �Ci OF AMERICIUM-241 HAD BEEN MISSING FROM FT. BRAGG (NORTH CAROLINA) SINCE |
| APRIL 1996 |
| |
| Late yesterday afternoon (03/16/00), representatives from Ft. Bragg, North |
| Carolina, requested the U.S. Army in Rock Island, Illinois, to help trace |
| files for documentation regarding a cell module that was discovered to be |
| missing from an M43A1 chemical agent detector. (The cell module contained |
| 250 �Ci of americium-241.) The most recent documentation found related to |
| the missing cell module indicated that it was last seen at Ft. Bragg in |
| April of 1996. More recent paperwork has not yet been found. The licensee |
| determined this event to reportable at approximately 1200 CST today |
| (03/17/00). |
| |
| The licensee hypothesized that the M43A1 chemical agent detector may have |
| been turned into a maintenance unit at some point. If the device tested |
| with bad air flow, the maintenance unit could have replaced several items |
| including the cell module. At this time, it is believed that the cell |
| module in question may have been removed (without any paperwork) and that |
| the device may have been returned without a replacement cell module |
| installed. |
| |
| The licensee stated that there does not appear to be any likelihood that the |
| general public will get involved with this issue. The licensee plans to |
| submit a 30-day written report to the NRC Region 3 office. (Call the NRC |
| operations officer for licensee contact information.) |
| |
| * * * UPDATE AT 1420 ON 03/30/00 BY MOHS RECEIVED BY WEAVER * * * |
| |
| The module was found on March 23, 2000. The Operations Center notified the |
| R3DO (Gardner) and R2DO (Caudle) and NMSS (Sherbini). |
| |
| ***** UPDATE AT 1631 ON 04/27/00 FROM JEFF HAVENNER TO LEIGH TROCINE ***** |
| |
| Based on a paper trail, the missing item was located at a Defense Logistics |
| Agency (DLA) facility in Anniston, Alabama. The M43A1 chemical agent |
| detector cell module was non-functional and had been removed during |
| maintenance. It was then turned in through channels and sent to this depot |
| facility. |
| |
| The NRC operations officer notified the R3DO (Shear), R2DO (Fredrickson), |
| and NMSS EO (Cool). |
+------------------------------------------------------------------------------+
!!!!!!!!! THIS EVENT HAS BEEN RETRACTED. THIS EVENT HAS BEEN RETRACTED !!!!!!!
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 36924 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: FARLEY REGION: 2 |NOTIFICATION DATE: 04/24/2000|
| UNIT: [1] [] [] STATE: AL |NOTIFICATION TIME: 16:26[EDT]|
| RXTYPE: [1] W-3-LP,[2] W-3-LP |EVENT DATE: 04/24/2000|
+------------------------------------------------+EVENT TIME: 12:53[CDT]|
| NRC NOTIFIED BY: WES CUMBEE |LAST UPDATE DATE: 04/27/2000|
| HQ OPS OFFICER: JOHN MacKINNON +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |ANN BOLAND R2 |
|10 CFR SECTION: | |
|AESF 50.72(b)(2)(ii) ESF ACTUATION | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N N 0 Refueling |0 Refueling |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| AUTOMATIC START OF THE PENETRATION ROOM FILTRATION SYSTEM DURING MAINTENANCE |
| ACTIVITIES. |
| |
| Maintenance investigation of a high vibration on "1B" Spent Fuel Pool |
| Exhaust fan resulted in the trip of the Spent Fuel Pool ventilation and |
| subsequent autostart of the Penetration Room Filtration System. All systems |
| operated as required. |
| |
| Operations restarted the Spent Fuel Pool ventilation and secured the |
| Penetration Room Filtration System. |
| |
| An investigation into this event is in progress. |
| |
| The NRC Resident Inspector was notified of this event by the licensee. |
| |
| ***** UPDATE AT 1357 EDT ON 04/27/00 FROM VAUDY HOLLY, JR. TO LEIGH TROCINE |
| ***** |
| |
| The licensee is retracting this event notification. The following text is a |
| portion of a facsimile received from the licensee: |
| |
| "This event has been evaluated further and determined to be an invalid |
| actuation based on 10 CFR 50.72(b)(2)(ii)(B)(3)(iv) and (v). An invalid |
| actuation of the fuel building ventilation system or auxiliary building |
| ventilation system is not reportable." |
| |
| "The accident analysis for fuel handling accidents in the spent fuel pool |
| (SFP) credits the high radiation signal initiation of SFP ventilation |
| isolation and penetration room filtration (PRF) system start. The low |
| differential pressure start of the PRF system is not credited; therefore, |
| PRF system actuation in the absence of a high radiation signal is not an |
| [engineered safety feature (ESF)] actuation. For the purposes of 10 CFR |
| 50.72, this is an invalid actuation." |
| |
| The licensee notified the NRC resident inspector. The NRC operations |
| officer notified the R2DO (Fredrickson). |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Fuel Cycle Facility |Event Number: 36934 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PADUCAH GASEOUS DIFFUSION PLANT |NOTIFICATION DATE: 04/27/2000|
| RXTYPE: URANIUM ENRICHMENT FACILITY |NOTIFICATION TIME: 12:45[EDT]|
| COMMENTS: 2 DEMOCRACY CENTER |EVENT DATE: 05/23/1998|
| 6903 ROCKLEDGE DRIVE |EVENT TIME: 06:13[CDT]|
| BETHESDA, MD 20817 (301)564-3200 |LAST UPDATE DATE: 04/27/2000|
| CITY: PADUCAH REGION: 3 +-----------------------------+
| COUNTY: McCRACKEN STATE: KY |PERSON ORGANIZATION |
|LICENSE#: GDP-1 AGREEMENT: Y |GARY SHEAR R3 |
| DOCKET: 0707001 |SCOTT MOORE NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: THOMAS WHITE | |
| HQ OPS OFFICER: LEIGH TROCINE | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|OCBB 76.120(c)(2)(ii) EQUIP DISABLED/FAILS | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| HISTORICAL REPORT OF THE DISCOVERY OF A FAULT CONDITION ON THREE MODULES ON |
| THE 'X' CRITICALITY ACCIDENT ALARM SYSTEM CLUSTER DURING 1998 (24-HOUR |
| REPORT) |
| |
| The following text is a portion of a facsimile received from Paducah: |
| |
| "At 0613 [CDT] on 05/23/98, the PSS was informed of a trouble alarm on C-337 |
| Criticality Accident Alarm System (CAAS) 'X' cluster. Investigation of |
| trouble alarm revealed that all three modules on [the] 'X' CAAS cluster were |
| in a 'Fault' condition. The cluster was reset, and the Fault condition |
| cleared. This condition was not reported as an event in which equipment |
| required by the [Technical Safety Requirement (TSR)] is disabled or fails to |
| function as designed as required by 10 CFR 76.120(c)(2). This event was |
| found during the investigation of Notification Worksheet No. 36880, which |
| occurred on 04/12/00. [The] 'X' CAAS cluster was in this 'Fault' condition |
| from 0613 [CDT] until 0722 [CDT on 05/23/98]. During this time, an area in |
| the Southeast corner of C-337, which contains a [Department of Energy (DOE)] |
| Material Storage Area (DMSA) that holds 55-gallon drums of potentially |
| fissile material, was without operable CAAS coverage." |
| |
| "This event should have been reported under 10 CFR 76.120(c)(2) as an event |
| in which equipment required by the TSR is disabled or fails to function as |
| designed." |
| |
| This issue was determined to be reportable yesterday afternoon. |
| |
| Paducah personnel notified the NRC resident inspector. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Other Nuclear Material |Event Number: 36935 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| REP ORG: NRC REGION 1 OFFICE |NOTIFICATION DATE: 04/27/2000|
|LICENSEE: DAVID BLACKMORE & ASSOCIATES |NOTIFICATION TIME: 13:48[EDT]|
| CITY: POTTSTOWN REGION: 1 |EVENT DATE: 04/27/2000|
| COUNTY: STATE: PA |EVENT TIME: [EDT]|
|LICENSE#: AGREEMENT: N |LAST UPDATE DATE: 04/27/2000|
| DOCKET: |+----------------------------+
| |PERSON ORGANIZATION |
| |JAMES NOGGLE R1 |
| |SCOTT MOORE NMSS |
+------------------------------------------------+ |
| NRC NOTIFIED BY: JAMES NOGGLE (R1DO) | |
| HQ OPS OFFICER: LEIGH TROCINE | |
+------------------------------------------------+ |
|EMERGENCY CLASS: N/A | |
|10 CFR SECTION: | |
|NDAM DAMAGED GAUGE/DEVICE | |
| | |
| | |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| DAVID BLACKMORE & ASSOCIATES REPORT TO NRC REGION 1 REGARDING A CRUSHED SOIL |
| DENSITY GAUGE IN POTTSTOWN, PENNSYLVANIA |
| |
| At 1345 on 04/27/00, Joe Hughes (the radiation safety officer at David |
| Blackmore & Associates) notified the NRC Region 1 office that a soil density |
| gauge was crushed at a construction site in Pottstown, Pennsylvania, near |
| Porter Road. Mr. Hughes was informed of the event and was en route to the |
| job site at the time of this notification to the NRC Region 1 office. Mr. |
| Hughes called the NRC Region 1 Office to ask advice and was not aware of the |
| event specifics. The NRC Region 1 office (Noggle) subsequently notified the |
| NRC operations center. |
| |
| The R1DO (James Noggle) stated that the NRC Office of Nuclear Materials |
| Safety and Safeguards (George Pangburn and Judith Joustra) had been |
| informed. |
| |
| (Call the NRC operations office for licensee contact information.) |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 36936 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: FITZPATRICK REGION: 1 |NOTIFICATION DATE: 04/27/2000|
| UNIT: [1] [] [] STATE: NY |NOTIFICATION TIME: 14:42[EDT]|
| RXTYPE: [1] GE-4 |EVENT DATE: 04/27/2000|
+------------------------------------------------+EVENT TIME: 10:50[EDT]|
| NRC NOTIFIED BY: BOB STEIGERWALD |LAST UPDATE DATE: 04/27/2000|
| HQ OPS OFFICER: DICK JOLLIFFE +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |JAMES NOGGLE R1 |
|10 CFR SECTION: |FEMA, DOE, USDA, HHS FAX |
|APRE 50.72(b)(2)(vi) OFFSITE NOTIFICATION |EPA, DOT (via NRC) FAX |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|1 N Y 90 Power Operation |90 Power Operation |
| | |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| - STATE DEC AND U.S. COAST GUARD NOTIFIED OF SMALL OIL DISCHARGE INTO LAKE |
| ONTARIO - |
| |
| The licensee notified the New York State Department of Environmental |
| Conservation (DEC), the U.S. Coast Guard, and the NRC Resident Inspector |
| that approximately two ounces of oil had discharged from the plant storm |
| drains into Lake Ontario. The oil has dispersed. The cause is unknown and |
| being investigated by the licensee. |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
|Power Reactor |Event Number: 36937 |
+------------------------------------------------------------------------------+
+------------------------------------------------------------------------------+
| FACILITY: PEACH BOTTOM REGION: 1 |NOTIFICATION DATE: 04/27/2000|
| UNIT: [2] [3] [] STATE: PA |NOTIFICATION TIME: 17:03[EDT]|
| RXTYPE: [2] GE-4,[3] GE-4 |EVENT DATE: 04/27/2000|
+------------------------------------------------+EVENT TIME: 16:05[EDT]|
| NRC NOTIFIED BY: JIM KOVALCHICK |LAST UPDATE DATE: 04/27/2000|
| HQ OPS OFFICER: LEIGH TROCINE +-----------------------------+
+------------------------------------------------+PERSON ORGANIZATION |
|EMERGENCY CLASS: N/A |JAMES NOGGLE R1 |
|10 CFR SECTION: | |
|AARC 50.72(b)(1)(v) OTHER ASMT/COMM INOP | |
| | |
| | |
| | |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|UNIT |SCRAM CODE|RX CRIT|INIT PWR| INIT RX MODE |CURR PWR| CURR RX MODE |
+-----+----------+-------+--------+-----------------+--------+-----------------+
|2 N Y 100 Power Operation |100 Power Operation |
|3 N Y 100 Power Operation |100 Power Operation |
| | |
+------------------------------------------------------------------------------+
EVENT TEXT
+------------------------------------------------------------------------------+
| LOSS OF POWER TO THE TECHNICAL SUPPORT CENTER |
| |
| At 1505 on 04/27/00, power was lost to the Peach Bottom Technical Support |
| Center (TSC) as a result of breaker malfunctions during planned electrical |
| switching. As of 1605, power had been out for greater than 1 hour |
| constituting a loss of emergency assessment capability at the TSC. |
| |
| Assessment capability remains in the main control room and the Emergency |
| Operations Facilities, and communication is still in tact between the |
| control room and the TSC. Troubleshooting and restoration activities by |
| maintenance and operations personnel are currently in progress, and this |
| condition does not affect either of the operating plants. |
| |
| The licensee stated that power to the TSC was lost when two breakers failed |
| to operate during performance of activities to restore power to a normal |
| lineup following maintenance work on lines that do not normally affect the |
| TSC. (However, when this particular lineup change is made, it realigns the |
| power going to the TSC.) When the two breakers failed to operate, power at |
| the TSC was lost. The licensee stated that the loss of power affected the |
| TSC only and that no other systems of facilities were affected. |
| |
| The licensee plans to notify the NRC resident inspector. |
| |
| ***** UPDATE AT 1729 ON 04/27/00 FROM JIM KOVALCHICK TO LEIGH TROCINE ***** |
| |
| Power was restored to the TSC at 1710 on 04/27/00. |
| |
| The licensee notified the NRC resident inspector. The NRC operations center |
| notified the R1DO (Noggle). |
+------------------------------------------------------------------------------+
Page Last Reviewed/Updated Wednesday, March 24, 2021
Page Last Reviewed/Updated Wednesday, March 24, 2021